1 / 1

Honeywell TK-RPCXX1 Series C Redundant Power Carrier Module

Honeywell TK-RPCXX1 Series C Redundant Power Carrier Module

Only 5 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TK-RPCXX1

  • Country of origin:Egyesült Államok

  • Product Type: PLC Power Supply Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 14.4 x 13.7 x 17.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Providing regulated electrical distribution to Experion Series C chassis, the Honeywell TK-RPCXX1 serves as a reliable redundant power supply carrier within process automation environments. Engineered with a robust, conformal coated assembly, this module is specifically hardened against moisture, dust, and corrosive airborne contaminants typical of heavy industrial facilities. It accepts dual wide-range AC inputs to ensure continuous control system operation even in the event of a primary power feed failure.

Features

  • Conformal Coated Circuitry: Designed for installation in harsh, Class G3 environments.
  • Dual Redundant Power Architecture: Enhances system availability by facilitating hot-swappable secondary power supply configurations.
  • Integrated Annunciation Relay: Built-in solid-state relay detects power failures and trips external diagnostic alarms.
  • Wide AC Input Acceptance: Accommodates global voltage standards from 85 to 265 VAC without manual switching.

Applications

  • Experion PKS Series C controller backplane power distribution.
  • Petrochemical and oil refinery distributed control systems (DCS).
  • Critical process industries requiring uninterruptible fieldbus and I/O power.

Technical Specifications

Parameter Specification Value
Manufacturer Honeywell
Model Number TK-RPCXX1
Environmental Protection Conformal Coated
Input Voltage Range 85 - 265 VAC
Input Power Rating 110 VA / 110 W
Frequency Range 47 - 63 Hz
Maximum Inrush Current 20 A
Total Output Power (Max) 75 W at 60 degC
Backplane Output Outputs 15 A at 5.0 V / 1.5 A at 15.0 V / 1.5 A at -15.0 V / 2.8 A at 24.0 V
Input Wiring Gauge #14 AWG (1.4 mm)
Annunciation Relay Rating Solid state, 120 VAC/DC at 100 mA maximum
Required Cable Model TC-RPSC03 (3 ft, redundant power supply connection)
Module Dimensions (L x D x H) 14.4 x 13.7 x 17.5 cm (5.67 x 5.39 x 6.89 in)
Carrier Weight 1.1 kg (2.5 lbs)
Shipping Weight (Calculated) 2.0 kg (4.4 lbs)

Empirical Engineering Insights

Alternative Models & Compatibility

The TK-RPCXX1 is the conformal-coated variant of the standard TC-RPCXX1 power carrier. In highly corrosive environments, the "TK" prefix series must be selected over the "TC" series to ensure long-term trace resilience against ambient hydrogen sulfide and chlorine. This carrier interfaces seamlessly with Honeywell Series C systems and connects via the TC-RPSC03 redundancy cable assembly.

Application Pitfalls & Engineering Notes

Maximum output power drops linearly above 60 degC ambient operating temperatures. Ensure that the module is mounted strictly in an upright orientation. Standard rack or panel configurations require at least 5 cm of clear space above and below the carrier chassis to allow natural thermal convection and avoid local hot spots inside the enclosure.

Commissioning & Wiring Tips

To minimize voltage sag and line-noise coupling, use exactly #14 AWG (1.4 mm) copper wire for the main AC feed. The integrated solid-state annunciation relay is highly sensitive to overcurrent; do not exceed the 100 mA load limit during commissioning tests, and always employ an external interposing relay if switching higher-current industrial indicator circuits.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all AC mains feeding the panel before attempting installation. Capacitors inside the connected power supply units store dangerous residual charge. Wait at least 5 minutes after physical de-energization before disconnecting or servicing cables.

1

Securely bolt the carrier chassis vertically in the designated system enclosure space, allowing clearance for proper ventilation.

2

Connect the TC-RPSC03 redundant power supply cable to the carrier connector, hand-tightening any locking screws.

3

Route and clamp the incoming AC supply conductors (#14 AWG) into the screw terminal block, ensuring correct polarity and solid ground termination.

4

Wire the solid-state alarm relay outputs to your distributed control system (DCS) monitoring inputs to complete commissioning setup.

What is the difference between TK-RPCXX1 and TC-RPCXX1?

The TK-RPCXX1 is conformal coated for G3-level environmental resistance against corrosive gases and moisture, whereas the TC-RPCXX1 standard version is not coated.

What size wire should be used for the AC input terminals?

The AC terminal block is designed and rated for #14 AWG (1.4 mm) copper wire.

Can the annunciation relay handle direct heavy loads?

No. The solid-state annunciation relay is rated for a maximum of 120 VAC/DC at 100 mA. It should only drive digital inputs or small interposing relays.

What cable is required to connect to the redundant power supplies?

The carrier requires the TC-RPSC03 redundant power supply cable for proper redundant power distribution.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...