1 / 1

Omron 3G3JZ-A2037 SYSDRIVE 3G3JZ Series Inverter

Omron 3G3JZ-A2037 SYSDRIVE 3G3JZ Series Inverter

Only 10 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: 3G3JZ-A2037

  • Country of origin:Japán

  • Product Type: 3G3JZ Series Inverter

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

The Omron 3G3JZ-A2037 is a compact, variable frequency AC drive within the SYSDRIVE 3G3JZ series, engineered to provide precise speed regulation for three-phase asynchronous motors. Operating on a 200V class three-phase electrical input, this hardware functions by converting standard line power into a variable-voltage, variable-frequency phase-to-phase sinusoidal PWM output to drive induction motors rated up to 3.7 kW. The inverter utilizes a high-efficiency V/f control strategy with built-in torque compensation to yield a robust starting torque of 150% or greater at lower operating frequencies. Equipped with native RS-485 Modbus serial communication, the unit coordinates directly with host programmable logic controllers like the Omron CP1L series for simple positioning control, automated data monitoring, and network integration inside machine control cabinets.

Features

  • Micro-sized variable frequency drive for space-restricted electrical sub-panels.
  • Built-in multi-function digital and analog control circuit terminal blocks.
  • Embedded RS-485 Modbus RTU communication channel for digital speed profiling and status reporting.
  • Torque compensation function supplying 150% output torque at 3 Hz.
  • Integrated energy-saving parameter options to maximize electrical motor operating efficiency.
  • Simple macro configuration routines suitable for standard industrial applications.
  • Protection framework safeguarding against line faults, overcurrent, and output short-circuits.

Applications

  • Mechanical transport lines, production conveyors, and localized material handling systems.
  • Standard industrial centrifugal pumps, booster stations, and fluid mixing apparatus.
  • Exhaust blowers, supply fans, and localized HVAC commercial air-handling equipment.
  • Packaging machinery lines, including wrapping machines and small-scale friction feeders.
  • Machine-tool spindle control and automated indexing mechanisms.

Technical Specifications

Power Requirements

Parameter Specification
Input Voltage Class 3-phase 200V Level
Rated Input Voltage 3-phase (3-wire) 200 to 240 VAC
Input Voltage Fluctuation Range 200 V -15% to 240 V +10%
Input Frequency 50/60 Hz
Input Frequency Fluctuation Range ± 5%

Output Specifications

Parameter Specification
Maximum Applicable Motor Capacity 3.7 kW
Rated Output Voltage 3-phase: 200 to 240 V (proportional to input voltage)
Output Control Method Phase-to-phase sinusoidal modulation PWM
Torque Performance 150% or more torque output at 3 Hz via torque compensation

Environmental

Parameter Specification
Enclosure Rating Enclosure Model A: Panel-mounting / Closed wall mounting (IP20 minimum)
Ambient Operating Temperature -10°C to +50°C (Close-mounting spacing: -10°C to +40°C)
Ambient Operating Humidity 90% RH maximum (non-condensing)
Storage Environment Must be free from corrosive or flammable gases, salt mist, and dense metallic dust

Mechanical

Parameter Specification
Installation Orientation Vertical wall mounting format
Shipping Weight 3 Kg

Installation Guidelines

  • Enclosure Orientation: Mount the drive vertically against a flat wall or sub-panel surface within the electrical enclosure. Do not install the unit horizontally or in an inverted plane.
  • Thermal Clearances: Maintain prescribed clearance distances from adjacent components or enclosure inner surfaces to allow for proper air circulation from the lower cooling fan up through the upper ventilation vents.
  • Wiring Safeguards: Ensure main power supply line lines are completely de-energized and verified via instrumentation for less than 10 minutes prior to opening the front wiring terminal shield block cover.
  • Output Isolation Warning: Connect exclusively three-phase induction motor loads to the U/T1, V/T2, and W/T3 power terminals. Never join AC mains supply electricity lines to these output connections, as doing so will cause immediate, severe hardware destruction.
  • Control Wiring Integrity: Keep sensitive low-voltage control terminal block lines separate from main power lines or motor feeder wires inside the panel routing channels to suppress electrostatic noise and high-frequency EMI.
  • Grounding Connection: Terminate a heavy gauge earth grounding lead directly to the structural grounding bolt. Ensure the overall path resistance measures 100 Ω or less for this 200V class machinery.

FAQ

  • What is the maximum electrical motor capacity supported by this module?
  • This model is rated to run three-phase motors with a maximum capacity of 3.7 kW.
  • What specific voltage supply class does this drive belong to?
  • It belongs to the 3-phase 200V class, with an operational input range of 200 to 240 VAC.
  • Does this unit support network communication out of the box?
  • Yes, it features a native RS-485 port supporting standard Modbus serial protocols.
  • What is the environmental index or chassis type of this specific housing?
  • It is an Enclosure Type A layout, matching an IP20 minimum rating suitable for panel mounting.
  • Can this VFD run on a single-phase 230V input line?
  • No, this unit is engineered strictly to handle a 3-phase, 3-wire incoming power supply line.
  • What type of motor control logic is utilized by the internal processor?
  • It utilizes phase-to-phase sinusoidal PWM modulation using adjustable torque compensation functions.
  • How should this product be oriented when installing inside a control panel?
  • It must always be installed vertically on a wall or flat sub-panel to allow the internal fans to draw cooling air upward.
  • What safety measures are needed for short-circuit line faults?
  • A molded case circuit breaker (MCCB) or protective industrial fuses calibrated to the drive ratings must be wired in series with the input power supply lines.
  • What happens if AC input power lines are mistakenly wired to the motor output terminals?
  • Connecting AC main line power directly to the motor output terminals (U/T1, V/T2, W/T3) will cause terminal hardware damage and destroy the drive internal components.
  • What is the physical weight of this model package for logistics purposes?
  • The baseline shipping weight of this inverted drive assembly is rated at 3 Kg.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Fekete
Country of origin
Japán

Nemrég megtekintett termékek

Műszaki ismeretek

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...