1 / 1

Omron CVM1-PA208 CVM1 Series Power Supply Unit

Omron CVM1-PA208 CVM1 Series Power Supply Unit

Only 2 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: CVM1-PA208

  • Country of origin:Japán

  • Product Type: PLC Power Supply Modules

  • Payment: T/T, Western Union

  • Weight: 9500g

  • Dimensions: 24.5 x 14.0 x 9.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Engineered specifically for legacy CV-series backplane architectures, the Omron CVM1-PA208 supplies reliable, low-noise DC control power directly to the rack's system buses. This high-capacity power module accepts a wide AC input range and converts it to a highly stable 5 VDC, 8 A output, which is crucial for maintaining processor integrity and preventing backplane communication errors. The unit is optimized for heavy-duty industrial configurations where PLC modules require consistent current supply without voltage sags.

Features

  • High-current 8 A output capacity at 5 VDC to power dense I/O racks and high-performance CPUs.
  • Flexible AC input selection accommodating standard industrial line voltages.
  • Integrated RUN output relay contact for external monitoring of power supply health.
  • Robust noise filter circuitry to shield sensitive internal logic from electrical line transients.
  • Overcurrent and overvoltage protection limits to prevent downstream component damage during field faults.

Applications

  • Omron CV500, CV1000, and CV2000 PLC Rack Installations.
  • Automotive assembly line host control units.
  • Large-scale material handling and distribution systems.
  • Water treatment and chemical plant automation backplanes.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number CVM1-PA208
Input Voltage 100 to 120 VAC / 200 to 240 VAC (selectable)
Frequency Rating 50 / 60 Hz
Output Voltage 5 VDC
Output Current 8 A
Power Consumption 150 VA
Operating Temperature 0 to 55 degC (32 to 131 degF)
Country of Origin Japan
Shipping Weight (Calculated) 1.50 kg
Package Dimensions (Calculated) 24.5 x 14.0 x 9.5 cm

Connections and Interfaces

Terminal Label Function / Circuit Assignment
AC100-120V / AC200-240V Main AC line power supply input terminals.
LG Line ground (noise filter ground) to reduce common-mode high-frequency interference.
GR Frame Ground terminal connected directly to the system grounding bar.
RUN OUT Relay contact terminals (SPST-NO) that close when the CPU is operating normally.

Alternative Models & Compatibility

The CVM1-PA208 power supply replaces standard or lower amperage modules within the CV family (such as 3 A and 5 A variants) to support system expansions containing high-density digital or analog cards. When updating backplane hardware, verify that total current consumption on the 5 VDC internal bus does not exceed the unit's 8 A output ceiling.

Application Pitfalls & Engineering Notes

Overheating in sealed, non-ventilated enclosures can lead to accelerated aging of the internal smoothing capacitors. Keep a minimum vertical spacing of 20 mm around the rack power unit to allow convective cooling. If output voltage drops below 4.75 VDC, the system watchdog will trip, halting PLC execution as a safety precaution.

Commissioning & Wiring Tips

Ensure that the Line Ground (LG) and Frame Ground (GR) terminals are wired correctly. Loop the GR terminal with a heavy, low-impedance ground strap directly to your panel plate. Leaving the GR terminal disconnected or sharing a daisy-chained ground with high-noise variable frequency drives (VFDs) can introduce electromagnetic interference, causing intermittent CPU memory corruptions.

Installation Guidelines

CRITICAL WARNING

Disconnect all incoming AC electrical power sources before handling, mounting, or wiring the terminal block. Touch hazards exist at input terminals when line power is applied. Verify the absence of voltage with a properly calibrated multimeter prior to starting system integration.

1 Align the bottom-hook mechanism of the power supply module with the designated base slot on the CV-series backplane.
2 Pivot the module smoothly upward into the backplane, pressing firmly until the top connector seat snaps completely home.
3 Secure the upper module retaining screw to the chassis to ensure mechanical grounding and guard against vibration-induced displacement.
4 Complete the electrical terminal wiring, torque terminal screws to 1.2 N-m, and apply protective terminal covers before energization.

Does this power supply unit support auto-ranging voltage input?

No. The input voltage range is manually configured or jumper-selected at the terminal block. Ensure that your terminal connections match the 100-120 VAC or 200-240 VAC supply lines before power up.

What is the function of the RUN OUT contact?

The RUN output is a dry relay contact that closes when the internal system logic voltage is normal and the CPU executes normally. It is commonly integrated into master control or safety circuit loops.

Can I upgrade my existing CV500 power supply to this 8 Amp module?

Yes. This high-capacity module is pin-compatible with CV500, CV1000, and CV2000 backplanes, offering a robust power upgrade for configurations containing power-hungry I/O or communication cards.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Japán

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...