Designed to act as a central operator interface within Sysmac system topologies, the Omron NS10-TV01-V2 HMI module offers exceptional visualization and touch control for demanding automation setups. This 10.4-inch active-matrix TFT display features integrated communication capabilities, enabling reliable, high-speed interaction with PLCs, motion controllers, and variable frequency drives on the plant floor.

Features

  • High-Visibility TFT Display: Crisp 10.4-inch display utilizing an energy-efficient LED backlight with wide viewing angles.
  • VGA Resolution: High-density 640 x 480 pixel grid optimizes screen real estate for complex graphical plant layouts.
  • Native Ethernet Port: Supports high-speed communications, project uploads/downloads, and remote web-based monitoring.
  • Industrial Construction: Durable ivory enclosure engineered to resist oil, chemicals, and physical impacts.
  • Efficient Power Envelope: Maximum 25 W power consumption on a standard industrial 24 VDC bus.

Applications

  • Assembly and manufacturing packaging lines.
  • Water and wastewater chemical dosing and level monitoring.
  • HVAC control and environmental chamber automation systems.
  • Multi-axis motion control configuration and diagnostic stations.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model NS10-TV01-V2
Series NS Series
Display Size & Type 10.4-inch TFT LED Backlight
Resolution 640 x 480 dots (VGA)
Ethernet Port Yes (10/100 Base-TX RJ45)
Case Color Ivory
Rated Power Voltage 24 VDC
Power Consumption 25 W maximum
Ambient Storage Temperature -20 to 60 degC
Ambient Operating Humidity 35% to 85% (0 to 40 degC), 35% to 60% (40 to 50 degC) non-condensing
Operating Atmosphere No corrosive gases
Weight 2.3 kg maximum
Shipping Weight (Calculated) 3.5 kg

Connections and Interfaces

Connector / Port Function / Circuit Assignment
Ethernet Port RJ45 interface for PLC communications and remote host connections.
Serial Port A RS-232C D-sub 9-pin connector for direct PLC link or legacy programming.
Serial Port B RS-232C D-sub 9-pin connector for auxiliary communication loops.
USB Ports Type-A for external storage; Type-B for PC-to-HMI project transfers.

Empirical Engineering Insights

Alternative Models & Compatibility

The NS10-TV01-V2 completely replaces older NS10-TV01 (non-V2) models. When upgrading, project files written in CX-Designer must be reconfigured in system properties to target the "V2" system hardware to ensure perfect touch-coordinate registration and display driver alignment.

Application Pitfalls & Engineering Notes

Operating the unit continuously above 40 degC without adequate ventilation in sealed enclosures may accelerate LED backlight degradation. Ensure panel layouts contain passive or active air circulation paths to keep ambient cabinet temperatures well below the 50 degC maximum limit.

Commissioning & Wiring Tips

To prevent grounding loops and electrical noise from distorting touchscreen responsiveness, always route the 24 VDC power supply using shielded twisted-pair cables. Ensure the HMI functional ground (FG) pin is wired directly to the single-point system cabinet earth bar using a dedicated, low-impedance copper conductor.

Installation Guidelines

CRITICAL WARNING: Prior to attempting any installation, physical placement, or electrical wiring modifications, ensure that all main incoming AC and DC control voltages to the enclosure are completely isolated. Confirm electrical zero with a calibrated digital multimeter before handling terminal connections.
1

Cut a standard rectangular opening in the enclosure door matching the panel cutout dimensions provided in the Omron installation manual.

2

Position the watertight rubber gasket flat and centered around the HMI bezel flange to ensure a proper IP65 environmental seal against moisture ingress.

3

Insert the HMI terminal through the cutout and secure it in place from behind using the supplied mounting brackets, tightening the screws to the specified torque range of 0.5 to 0.6 Nm.

4

Connect the 24 VDC power supply wires and functional ground to the terminal block, then interface the RJ45 Ethernet link cable with the controller network switch.

What software is used to program the NS10-TV01-V2 operator interface?

This terminal is programmed and designed using CX-Designer software, which is part of the CX-One automation suite from Omron.

Does the V2 variant support USB peripheral connections?

Yes, the V2 terminal features a built-in USB Type-A port for data logging or external memory drives, and a USB Type-B port for high-speed programming connectivity.

What should be checked if the screen is powered but remains entirely dark?

Verify that the input voltage at the power terminal blocks is stable at 24 VDC. If voltage is present, the LED backlight may have timed out based on its configurable sleep parameters in the system menu.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Japán

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...