  • Manufacturer: ProSoft

  • Product No.: MVI56E-MCMXT

  • Country of origin:Egyesült Államok

  • Product Type: Modbus Communication Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 250 mm x 150 mm x 60 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Providing seamless serial connectivity within Allen-Bradley ControlLogix control architectures, the ProSoft MVI56E-MCMXT functions as an industrial-grade Modbus Master/Slave interface module designed specifically for extreme environments. This extended-temperature module permits Allen-Bradley ControlLogix processors to interface directly with diverse Modbus serial field devices, including flow computers, power monitors, variable frequency drives, and remote terminal units (RTUs). Equipped with conformal coating and robust electrical isolation, it delivers continuous protocol translation in demanding industrial operations where standard communication cards are prone to environmental failure.

Features

  • Dual Independent Ports: Two individually configurable serial ports capable of operating concurrently as Modbus Master and/or Modbus Slave nodes.
  • Extended Environmental Tolerance: Conformal-coated circuitry engineered to withstand corrosive atmospheres, moisture, and extreme temperature variations.
  • Rockwell Automation Integration: Integrates directly into the 1756 ControlLogix chassis, utilizing custom Add-On Instructions (AOI) and Add-On Profiles (AOP) for simplified RSLogix 5000 and Studio 5000 programming.
  • Advanced Diagnostics: Dedicated 10/100 Mbps Ethernet port (CFG) provides diagnostic visualization, parameter adjustments, and firmware updates via the ProSoft Configuration Builder (PCB) utility.
  • Protocol Versatility: Native support for Modbus RTU and Modbus ASCII formats with configurable parity, baud rates, stop bits, and RTS timing parameters.

Applications

  • Oil and Gas Processing: Interfacing custody transfer flow meters, gas chromatographs, and tank gauging systems to a central ControlLogix processor.
  • Water and Wastewater Treatment: Integration of scattered chemical dosing pumps, flow sensors, and remote RTUs over long-distance serial topologies.
  • Power Utility Systems: Consolidating data from protective relays, power quality monitors, and generator control panels.
  • Chemical Manufacturing: Safe operation in corrosive process environments where standard non-conformal coated communication cards risk premature corrosion failure.

Technical Specifications

Specification Parameter Value / Detail
Manufacturer ProSoft Technology
Model Number MVI56E-MCMXT
Module Series MVI56E Enhanced Modbus Serial
Platform Compatibility Allen-Bradley ControlLogix (1756 Chassis)
Modbus Protocol Modes Modbus RTU (Binary) with CRC-16, Modbus ASCII with LRC checking
Supported Baud Rates 110 to 115,200 baud
Data/Stop Bits & Parity Stop bits: 1 or 2; Parity: None, Even, Odd
RTS Timing Delays 0 to 65,535 milliseconds
Conformal Coating Yes (Extended environmental protection)
Operating Temperature -25 degC to 70 degC (-13 degF to 158 degF)
Backplane Current Draw 800 mA @ 5 VDC, 3 mA @ 24 VDC
Country of Origin United States
Shipping Weight (Calculated) 2.0 kg (approx. 4.4 lbs)
Package Dimensions (Calculated) 250 mm x 150 mm x 60 mm

Connections and Interfaces

Port Reference Physical Interface Electrical/Functional Assignment
PRT1 (Port 1) RJ45 (DB9 adapter cable included) Modbus Master/Slave Serial Port (RS-232, RS-422, or RS-485 configurable)
PRT2 (Port 2) RJ45 (DB9 adapter cable included) Modbus Master/Slave Serial Port (RS-232, RS-422, or RS-485 configurable)
CFG (Configuration) RJ45 10/100 Mbps Ethernet Dedicated configuration, system utility upload/download, and remote diagnostics

Alternative Models & Compatibility

The MVI56E-MCMXT is the ruggedized, conformal-coated alternative to the standard MVI56E-MCM module. It is backward-compatible with legacy MVI56-MCM data structures, allowing it to serve as a direct physical and logical drop-in replacement in older ControlLogix systems. This compatibility prevents the need to completely rewrite the underlying PLC ladder logic. Note that when replacing older standard modules with this extended-temperature version, the modern Add-On Instructions should be reviewed to leverage the enhanced memory mapping capabilities of the MVI56E line.

Application Pitfalls & Engineering Notes

When calculating system power budgets, engineers must account for the module's high current draw on the backplane (800 mA at 5 VDC). Placing multiple communication modules in a single 1756 chassis without verifying the power supply capacity (e.g., 1756-PA75) can trigger under-voltage faults or intermittent CPU resets. Additionally, when using RS-485 2-wire serial networks, failing to install 120-ohm termination resistors on the terminal nodes of long cable segments will result in waveform reflection, manifesting as intermittent Modbus CRC validation errors.

Commissioning & Wiring Tips

During initial system configuration, connect to the CFG Ethernet port using the ProSoft Configuration Builder (PCB) software. Ensure that the PC's network interface adapter matches the IP subnet configured on the module. If using the RJ45-to-DB9 serial adapters provided, ensure proper routing of the signal shield to a clean chassis ground. When configuring a 2-wire RS-485 bus, the RX and TX terminals on the DB9 must be bridged externally as defined in the ProSoft connection schematics to ensure correct half-duplex transceiver operation.

Installation Guidelines

CRITICAL WARNING

Disconnect all primary power to the ControlLogix chassis and connected serial equipment prior to inserting or extracting any module. Hot-swapping modules in hazardous locations can cause electrical arcing, resulting in severe physical injury, equipment damage, or explosive ignition risks.

1
Align the MVI56E-MCMXT module with the circuit card guides of the selected vacant slot in the 1756 chassis. Ensure the module is oriented correctly with the faceplate text upright.
2
Slide the module firmly into the slot until the top and bottom chassis levers click securely, indicating full insertion into the passive backplane connectors.
3
Secure the serial communications cabling to the RJ45 ports (PRT1/PRT2) using the provided adapter cables. Securely fasten the DB9 connector screws to prevent accidental disconnection.
4
Restore system power. Monitor the scrolling LED status display on the front panel to verify self-test completion, active communication, and protocol diagnostic codes.

What is the primary difference between the standard MVI56E-MCM and the MVI56E-MCMXT?

The MVI56E-MCMXT is chemically conformal-coated and has an extended operating temperature range of -25 degC to 70 degC, whereas the standard module is rated for 0 degC to 60 degC and lacks environmental protective coatings.

Can I replace an older MVI56-MCM module with the newer MVI56E-MCMXT?

Yes. The MVI56E-MCMXT is backward-compatible. It can read configuration structures legacy modules use, allowing direct hardware replacement without rewriting existing ladder logic routines.

How do you switch the serial ports between RS-232, RS-422, and RS-485?

The electrical interfaces are jumperless. Port type selection is configured via software settings within the ProSoft Configuration Builder (PCB) and applied through the configuration download.

Does the MVI56E-MCMXT support Modbus over TCP/IP?

No. The MVI56E-MCMXT is exclusively designed for serial Modbus RTU and Modbus ASCII. Its onboard Ethernet port is dedicated for setup, diagnostic monitoring, and configuration upload/download, not for run-time field device Modbus TCP communications.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...