1 / 4

Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

Only 10 item(s) left in stock
  • Manufacturer: Yokogawa

  • Product No.: AAT141-S00

  • Country of origin:Japán

  • Product Type: TC/mV Input Modules

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 32.8 x 130 x 125.5 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

The Yokogawa AAT141-S00 is a 16-channel isolated thermocouple and millivolt input module designed for FIO systems within CENTUM VP field control stations. It functions as a signal converter by inputting field temperature and voltage signals into internal data for the Field Control Station (FCS). The AAT141-S00 module receives signals from thermocouple types J, K, E, B, R, S, T, and N, as well as mV voltage spans ranging from -100 to 150 mV and -20 to 80 mV. It supports dual-redundant configuration and connects externally via a pressure clamp terminal block.

Features

  • 16 isolated input channels for thermocouple and mV signals.
  • Software-selectable TC/mV input types individually configured for CH1 to CH16.
  • Dual-redundant configuration capability.
  • Dedicated pressure clamp terminal external connection interface.
  • Software-configurable burnout detection (UP/DOWN/Not available) for all channels.

Applications

  • Process temperature monitoring using thermocouples.
  • Millivolt analog input signal interfacing in CENTUM VP FIO DCS environments.
  • High-reliability industrial control systems requiring isolated I/O modules.

Ordering Information

Model Suffix Codes Option Codes Description
AAT141     TC/mV Input Module (16-channel, Isolated)
Suffix -S   Standard type
  0   With no explosion protection
  0   Basic type

Technical Specifications

Category Item Specification
Basic Specifications Manufacturer Yokogawa
  Model AAT141-S00
  Number of Input Channels 16, isolated
Input Specifications Input Signal

TC: JIS C1602:1995, IEC584:1995 Type J, K, E, B, R, S, T, N


 

mV: -100 to 150 mV, -20 to 80 mV

  Switching Input Signals TC/mV can be set individually for CH1 to CH16
  Allowable Input Voltage +/-5 V
  Input Resistance (Power ON/OFF) 2 MOhm or larger
Performance Accuracy

+/-30 uV (TC)


 

+/-80 uV for span (-100 to 150 mV)


 

+/-30 uV for span (-20 to 80 mV)

  Reference Junction Compensation Accuracy Within +/-1 degC (varies depending on installation and ambient temperature)
  Allowable Total Resistance 1000 Ohm or less (signal source plus wiring)
  Effect of Signal Source Resistance +/-20 uV per 1000 Ohm (+/-40 uV in dual-redundant configuration)
  Temperature Drift

+/-80 uV/10 degC (-100 to 150 mV input)


 

+/-30 uV/10 degC (TC/-20 to 80 mV input)

  Data Update Period 1 s
  Burn-out Detection All channels can be set together (Not available/available UP/DOWN), Detection time: 60 s
Electrical & Insulation Withstanding Voltage Between input and system: 1500 V AC, for 1 minute
  Maximum Current Consumption 450 mA (5 V DC)
Physical Specifications Weight 0.2 kg
  External Connection Pressure clamp terminal

Installation Guidelines

  • Use a non-ground type thermocouple (TC) because the device is an isolated type module; using ground type TC on multiple channels causes temperature errors due to multi-point ground.
  • Ensure proper installation onto supported ESB, Optical ESB, or ER bus node units.
  • Maintain matching wiring resistance for signal cables to ensure measurement accuracy.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

What input signal types are supported by the module?

The module supports thermocouple types J, K, E, B, R, S, T, and N, as well as mV voltage inputs ranging from -100 to 150 mV and -20 to 80 mV.

Why must non-ground type thermocouples be used with this module?

Because the module is an isolated type, using a ground type thermocouple across multiple channels causes temperature measurement errors due to multi-point grounding.

What is the maximum current consumption for the device?

The maximum current consumption is 450 mA at 5 V DC.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Japán

Nemrég megtekintett termékek

Műszaki ismeretek

OpenVMS Alphán futó Bailey INFI 90 Symphony HMI-k korszerűsítése

Gyakorlati útmutató az OpenVMS Alpha rendszeren futó, elöregedett Bailey Symphony kezelőállomások lecseréléséhez. Összehasonlítja az Alpha-emulációt, az OpenVMS x86-ra történő migrációt, az...

Miért elengedhetetlenek a karbantartási adatok az ipari megbízhatósághoz

A karbantartási adatok összekapcsolják a munkamegrendeléseket, az érzékelőjelek adatait, az eszközelőzményeket, a költségeket és a technikusok tudását. Megfelelő használat mellett javítják a...

A folyadékalapú erőrendszerek kiváltására tervezett elektromos működtetők: gyakorlati útmutató az ipari automatizáláshoz

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos aktuátorok, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést a hagyományos pneumatikus és hidraulikus rendszerek...

Matematikai műveletek OpenPLC használatával ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC-rendszerek olyan alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban....

Haladó Boole-logika FBD-s PLC-programozással: gyakorlati ipari alkalmazások az alapvető logikán túl

A cikk a PLC-programozásban az alapvető ÉS, VAGY és NEM műveleteken túl használt számos fejlett Boole-logikai függvényt ismertet. Bemutatja, hogyan alkalmazhatók az olyan eszközök, mint az...

Boole-logika PLC-programozásban: az FBD logikai kapuinak megértése

A Boole-féle logika minden PLC-program alapja. Az egyszerű gépvezérléstől a komplex ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...