The ADV142-P13 S1 (ADV142) is a robust 16-channel isolated digital input module designed for the Yokogawa CENTUM VP distributed control system (DCS). Specifically engineered to interface with high-voltage 200 V to 240 V AC signals, this module is essential for monitoring the status of heavy-duty industrial equipment such as motor starters, switchgear, and large-scale actuators. The ADV142 features integrated pushbutton input logic, allowing for the precise counting of signal edges in operator-interface applications. This unit is built for extreme reliability, featuring ISA Standard G3 conformal coating to resist corrosive gases and an extended operating temperature range of -20 to 70 deg C. By supporting dual-redundant configurations and providing high-level galvanic isolation, the module ensures continuous process monitoring and significantly reduces the risk of unplanned downtime in harsh environments like oil refineries, power plants, and chemical processing facilities.

Suffix Breakdown

The suffix codes for the ADV142-P13 define its specialized hardware hardening and functional capabilities:

  • -P: Equipped with the Pushbutton Input function, allowing the module to detect and count the edges of pushbutton signals with a dedicated minimum detection time.

  • 1: Categorized as a General-purpose type, optimized for standard high-voltage AC sensing within the FIO subsystem.

  • 3: Includes the ISA Standard G3 corrosion resistance option and the extended ambient temperature option (-20 to 70 deg C).

  • S1: Designates the Style 1 hardware revision, ensuring compatibility with current CENTUM VP node units and field network I/O.

Technical Specifications

Feature Specification
Model ADV142-P13 S1
Brand Yokogawa
Origin Japan
Input Channels 16, isolated (8 channels per common)
Rated Input Voltage 200 to 240 V AC (50/60 Hz)
Input ON Voltage 160 V AC (226 V Peak) to 264 V AC
Input OFF Voltage 40 V AC (56 V Peak) or less
Withstanding Voltage 2 kV AC (Input to System) / 1.35 kV AC (Between Commons)
Operating Temp -20 to 70 deg C
Environmental Rating ISA Standard G3 (Conformal Coating)
Weight Approx. 0.30 kg

Technical FAQs

How does the G3 option benefit the module's lifespan?

The G3 option applies a specialized conformal coating that protects internal circuitry from atmospheric corrosion caused by gases like Hydrogen Sulfide (H2S), Chlorine (Cl2), and Nitrogen Dioxide (NO2), which are common in paper mills and wastewater treatment plants.

What is the critical phase requirement for wiring this module?

All AC input signals connected to the same common minus (-) side (grouped every 8 channels) must be on the same electrical phase. Connecting multiple phases to a single common can cause catastrophic hardware failure.

Can this module handle high-frequency pulse signals?

No. While the ADV142 has a pushbutton counting function, it is limited to a maximum cycle of 2.5 Hz. For high-speed pulse counting (up to 10 kHz), a dedicated pulse input module like the AAP135 is required.


Engineering & Installation Guide

  • High-Voltage Safety: The ADV142 processes potentials up to 264 V AC. Ensure all field power is isolated before wiring the pressure clamp terminals. Use 1.25 mm2 or smaller cross-sectional area wire and verify that the terminal covers are securely installed to prevent accidental contact.

  • Thermal Considerations: When operating at the upper limit of the temperature range (up to 70 deg C), ensure the control cabinet has active ventilation. Avoid placing high-heat generating modules (like power supplies) directly beneath the ADV142 to prevent localized overheating.

  • Signal Integrity: To minimize electromagnetic interference (EMI), route the high-voltage AC input cables away from low-voltage DC signal lines. Use shielded cables if the wiring run exceeds 50 meters, and ground the shield at the cabinet end only.

  • Cable Selection: For reliable high-density connections, the use of the Yokogawa AKB333 dedicated cable is recommended. This cable is specifically designed to meet the insulation requirements for 220 V AC signals across 16 channels.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa ADV142-P13 S1 CENTUM VP AC Digital Input Module

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Szürkésfehér
Country of origin
Japán
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...