Yokogawa Wins Samarco DCS and SIS Order Across Two Brazilian Sites
Yokogawa will supply DCS, SIS, field instruments and services for Samarco’s Germano and Ubu operations, covering more than 50,000 physical and communication I/O points.
Yokogawa Electric announced on November 12, 2026 that its South American subsidiary has received an order from Samarco Mineração to supply distributed control systems, safety instrumented systems, field instruments, and related services for two Brazilian iron-ore operations. The scope covers the Germano mining complex in Minas Gerais and the Ubu pellet production facilities in Espírito Santo. Yokogawa says the new systems will include more than 50,000 I/O points when physical and communication points are counted together.

The order is significant for automation teams because it is not a single-unit controller refresh. It links control and safety work across mining, mineral processing and pellet production at sites roughly 400 km apart, while introducing Ethernet-APL, PROFINET S2 and PROFIsafe into a large brownfield environment.
What Yokogawa has confirmed
According to Yokogawa’s release, Samarco will partially replace existing control systems at both the Germano and Ubu facilities with Yokogawa DCS and SIS solutions. The upgrade also includes pressure and flow instruments. Process coverage runs from crushing, grinding and flotation at the mining side through pelletizing and induration at the coastal production site.
Yokogawa did not identify every controller, safety node, I/O family or instrument model in the public announcement. It also did not publish a detailed migration sequence, commissioning date or allocation of the 50,000-plus points by protocol. Those details should therefore not be inferred from the announcement. The confirmed scope is the combination of control, safety, field instrumentation, services and the named industrial-network technologies.
Why the protocol mix matters
Ethernet-APL extends Ethernet communication toward field instruments over a two-wire, powered physical layer designed for process environments. In practical migration work, its value depends on more than bandwidth: teams must check trunk and spur design, hazardous-area rules, switch and field-device profiles, power budgets, cable reuse limits and asset-management integration.
PROFINET S2 allows a device to maintain relationships with two I/O controllers, supporting system-level availability when the architecture and device profiles are configured correctly. It is not a substitute for every form of controller or network redundancy. Engineering teams still need to document failover behavior, controller ownership, diagnostic handling and what happens during firmware or network maintenance.
PROFIsafe carries safety-related data over the standard communication system using its own safety mechanisms. Its presence in the announced technology set does not by itself establish a particular safety integrity level for every loop. The final safety function depends on the complete sensor, logic solver, final element, application program, proof-test plan and lifecycle evidence.
Brownfield checks will determine the migration risk
For an installed plant, the engineering challenge is preserving production and protection while changing platforms. The DCS cutover plan must reconcile legacy I/O databases, signal conditioning, alarm priorities, control narratives and sequence logic. The SIS work has a stricter evidence burden: each safety requirement, cause-and-effect relationship, bypass rule and proof-test interval needs controlled transfer and validation.
The physical and communication I/O total also makes naming and marshalling discipline important. A communication point may carry a richer data set than a conventional analog loop, but that does not remove the need to prove the measurement path. Tag naming, units, ranges, damping, status handling and bad-quality behavior should be checked from field device to operator display and historian.
Existing spare-parts strategy remains relevant during a phased migration. Plants normally need to support old and new architectures in parallel until the final unit is converted and the rollback window closes. Procurement teams should separate parts required for current production support from hardware reserved for the new platform, with firmware, project revision and hazardous-area approvals recorded for each item.
What this means for Yokogawa system maintenance
The announcement does not say that specific catalog items on the open market form part of Samarco’s order. However, it illustrates the purchasing distinction between a system project and a spare-part request. A replacement item such as a Yokogawa SSC50D ProSafe-RS safety control unit must be checked against the installed cabinet, software release, redundancy design and project files; a shared product family name is not enough.
The same applies to a Yokogawa AFV30S CENTUM VP field control unit. Order-code suffixes and node configuration can define options that are invisible in a broad project announcement. For field I/O, the replacement checks in our Yokogawa AAI835 wiring and barrier guide show why terminal arrangement, isolation and barrier requirements should be verified before a swap.
Procurement questions to carry into the project
- Which DCS, SIS and remote-I/O product families are in the final bill of materials?
- How are PROFINET S2 controller relationships and maintenance failover tested?
- Which safety functions use PROFIsafe, and what lifecycle documentation supports them?
- Where will Ethernet-APL switches and powered spurs be installed, and which existing field cables are reusable?
- What spares are required during coexistence of the old and new systems?
- Which firmware, project and approval records must accompany each replacement unit?
Editorial assessment: the 50,000-plus-point figure shows the scale, but the most consequential engineering work will be at the boundaries: legacy-to-new I/O mapping, safety validation, protocol failover, field-device data quality and the controlled coexistence of two automation generations. Those are the areas where a nominally correct component can still become the wrong spare or the wrong configuration.
Source: Yokogawa Electric Corporation press release, published November 12, 2026: Yokogawa Receives Order from Brazilian Mining Company Samarco to Supply Control and Safety Systems.