1 of 1

Yokogawa SSC50D-S2521 ProSafe-RS Duplexed Safety Control Unit

Yokogawa SSC50D-S2521 ProSafe-RS Duplexed Safety Control Unit

Only 1 item(s) left in stock
  • Manufacturer: Yokogawa

  • Product No.: SSC50D-S2521

  • Country of origin:Japan

  • Product Type: 15-inch display 1024 x 768

  • Payment: T/T, Western Union

  • Weight: 13000g

  • Dimensions: 130 mm x 482 mm x 310 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Yokogawa SSC50D-S2521 is a rack-mountable duplexed safety control unit engineered for the ProSafe-RS Safety Instrumented System (SIS). The SSC50D-S2521 operates as a Safety Control Station (SCS) CPU node over the dual-redundant Vnet/IP control network to perform critical safety control, sequence-of-events recording (SOER), and subsystem integration functions. Certified by TÜV to meet Safety Integrity Level 3 (SIL 3) standards specified in IEC 61508, the SSC50D-S2521 delivers high-reliability execution for emergency shutdown, burner management, and safety interlock applications across process industries.

Features

  • Fully redundant, duplexed architecture designed for high availability in SIL 3 safety applications.
  • Integrates directly with the Vnet/IP gigabit Ethernet-based dual-redundant control network.
  • Connects to safety node units (I/O nodes) via dual-redundant ESB bus interface connections.
  • Supports inter-SCS safety communication over Vnet/IP to form distributed safety loops.
  • Provides Modbus master/slave interface capabilities via serial or Ethernet communication modules.

Applications

  • Emergency Shutdown Systems (ESD)
  • Burner Management Systems (BMS)
  • Fire and Gas Detection Systems (FGS)
  • Process Safety Management in chemical, petrochemical, and oil & gas facilities

Technical Specifications

Category Specification
Manufacturer Yokogawa
System Name ProSafe-RS Safety Instrumented System
Unit Type Duplexed Safety Control Unit (Standard Type)
Mounting Type Rack Mountable
Safety Integrity Level SIL 3 (IEC 61508)
Control Network Vnet/IP (Dual-Redundant Gigabit Ethernet)
I/O Bus Interface ESB Bus (Dual-Redundant, 128 Mbits/sec)
Operating Temperature -20 to 40 degC
Storage Temperature -40 to 85 degC
Operating Humidity 5 to 95% RH (non-condensing)
Temperature Rate of Change Within +-10 degC/h (operating), Within +-20 degC/h (storage)
Power Supply Options 100 to 120 V AC, 220 to 240 V AC, or 24 V DC
AC Voltage Range 100 to 120 V AC (-15% to +10%), 220 to 240 V AC (-15% to +10%)
DC Voltage Range 24 V DC (-10% to +20%)
Power Frequency 50/60 Hz +-3 Hz
Withstanding Voltage 1500 V AC for 1 min (AC models), 500 V AC for 1 min (24 V DC)
Insulation Resistance 20 M ohms at 500 V DC
Vibration Resistance Continuous: 1.75 mm (5 to 9 Hz), 4.9 m/s2 (9 to 150 Hz)
Shock Resistance 147 m/s2, 11 ms
Operating Altitude 2000 m above sea level or less
Corrosive Gas ANSI/ISA S71.04 G3

Installation Guidelines

  • Cabinet Enclosure: For rack-mounted units to comply with safety and EMC standards, the unit must be housed in a lockable metal cabinet.
  • Grounding Requirements: Provide independent grounding with a ground resistance of 100 ohms or less.
  • Power Wiring Protection: Dedicated breakers conforming to applicable safety standards (such as CSA C22.2 No.5, UL 489, EN 60947-1, or EN 60947-3) must be installed in the power distribution board.
  • Vnet Cable Setup: Install the specified clamp filter (A1193MN) to the Vnet communication cable as required for EMC compliance.
  • ESB Bus Distance Limits: Keep the standard dedicated ESB bus cable length within 10 meters from the CPU node ports.

Compliance and Certifications

  • Functional Safety: Certified SIL 3 according to IEC 61508.
  • PLC Standard: Complies with IEC 61131-2.
  • Application Standards: EN 54, EN 298, EN 50156-1, IEC 61511-1, IEC 62061, NFPA72, NFPA85.
  • Safety Standards: CAN/CSA-C22.2 No.61010-1, EN 61010-1, EN 61010-2-030.
  • EMC Standards: EN 55011 Class A Group 1, EN 61000-6-2, EN 61000-3-2, EN 61000-3-3, C-Tick Marking, KC Marking.
  • Hazardous Location Certifications: FM Non-Incendive (Class I Division 2 Groups A, B, C, D T4), Type "n" (II 3 G Ex nA IIC T4 Gc / II 3 G Ex nA nC IIC T4 Gc).
  • Marine Standards: ABS, BV, Lloyd's Register.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa SSC50D-S2521 ProSafe-RS Duplexed Safety Control Unit

What safety standard certification does the unit comply with?

The unit is certified by TÜV to meet Safety Integrity Level 3 (SIL 3) according to the IEC 61508 functional safety standard.

What is the operating temperature range for the standard type unit?

The normal operating temperature range for the basic standard safety control unit is from -20 degC to 40 degC.

What control network protocol does the device use?

The device communicates using the dual-redundant Vnet/IP gigabit Ethernet-based control network.

What type of cabinet enclosure is required for installation?

To comply with safety and EMC standards, the rack-mounted unit must be housed inside a lockable metal cabinet.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...