Description

Engineered for decentralized automation environments, the Beckhoff IP2312-B800 is a ruggedized digital I/O fieldbus box that facilitates direct signal interfacing in the field without the need for a protective control cabinet. This module integrates a balanced combination of four digital inputs and four digital outputs, communicating via a reliable RS485 physical interface.

The unit features robust M12 connections, allowing for secure and quick cabling of field devices and network communication. Designed to withstand harsh industrial conditions, the IP2312-B800 is ideal for localized control structures where fast signal acquisition (0.2 ms input filter) and reliable actuator switching (0.5 A per output channel) are required.

Features

  • Four digital inputs with a fast 0.2 ms signal filter to ensure accurate pulse detection.
  • Four digital outputs sourcing up to 0.5 A per channel at 24 V DC.
  • RS485 interface optimized for serial industrial fieldbus protocols.
  • Industrial-grade M12 screw connectors for secure signal, power, and bus routing.
  • Highly durable IP67-rated enclosure resistant to dust, moisture, and mechanical vibrations.

Applications

  • Decentralized conveyor systems and material handling routing.
  • Machine-mount sensor/actuator hubs in automotive and manufacturing assembly lines.
  • Food processing and packaging facilities requiring washdown protection.
  • Distributed remote I/O processing over long-distance RS485 links.

Technical Specifications

Manufacturer BECKHOFF
Model/Part Number IP2312-B800
Module Type Fieldbus Box I/O Module
Communication Interface RS485
Digital Inputs 4 channels (24 V DC)
Input Filter Time 0.2 ms
Digital Outputs 4 channels (24 V DC)
Max. Output Current 0.5 A per channel
Connection Technology M12 round connectors
Protection Class IP67
Shipping Weight 2.0 kg

Connections and Interfaces

Connection Type Connector Style Function
Fieldbus M12 RS485 Incoming and Outgoing lines
Digital Inputs M12 Channels 0 to 3 for 24 V DC sensors
Digital Outputs M12 Channels 0 to 3 for 24 V DC / 0.5 A actuators
Power Supply M8 / M12 24 V DC control voltage input and downstream feed

Installation Guidelines

  • Mounting: Secure the module directly to the machine frame or flat surfaces using the integrated mounting holes. Ensure the mounting surface is clean and level.
  • Grounding: Connect the functional ground (FE) directly to the machine potential via low-resistance grounding straps.
  • Torque Spec: Hand-tighten all M12 and M8 connections, then apply the specified torque of 0.6 Nm using an industrial torque wrench to maintain the IP67 protective seal.
  • Cabling: Keep signal and communication cables separate from high-voltage AC lines to prevent electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Beckhoff IP2312-B800?
The IP2312-B800 is a decentralized fieldbus box that connects 4 digital inputs and 4 digital outputs directly to an RS485 network in harsh IP67-rated environments.
What is the current rating for the digital outputs on this module?
Each digital output channel can source up to 0.5 A at 24 V DC.
What is the response or filter time for the digital inputs?
The module has a built-in input filter time of 0.2 ms for fast and accurate signal processing.
Does this module require an additional control enclosure?
No, because the IP2312-B800 is IP67 rated, it can be mounted directly on machinery without an external control cabinet.
Reviews

IP2312-B800

Stock & lead time on request

Call
1 su 1

BECKHOFF IP2312-B800 Fieldbus Box Digital I/O Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2312-B800

  • Country of origin:Germany

  • Product Type: Fieldbus Box Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Engineered for decentralized automation environments, the Beckhoff IP2312-B800 is a ruggedized digital I/O fieldbus box that facilitates direct signal interfacing in the field without the need for a protective control cabinet. This module integrates a balanced combination of four digital inputs and four digital outputs, communicating via a reliable RS485 physical interface.

The unit features robust M12 connections, allowing for secure and quick cabling of field devices and network communication. Designed to withstand harsh industrial conditions, the IP2312-B800 is ideal for localized control structures where fast signal acquisition (0.2 ms input filter) and reliable actuator switching (0.5 A per output channel) are required.

Features

  • Four digital inputs with a fast 0.2 ms signal filter to ensure accurate pulse detection.
  • Four digital outputs sourcing up to 0.5 A per channel at 24 V DC.
  • RS485 interface optimized for serial industrial fieldbus protocols.
  • Industrial-grade M12 screw connectors for secure signal, power, and bus routing.
  • Highly durable IP67-rated enclosure resistant to dust, moisture, and mechanical vibrations.

Applications

  • Decentralized conveyor systems and material handling routing.
  • Machine-mount sensor/actuator hubs in automotive and manufacturing assembly lines.
  • Food processing and packaging facilities requiring washdown protection.
  • Distributed remote I/O processing over long-distance RS485 links.

Technical Specifications

Manufacturer BECKHOFF
Model/Part Number IP2312-B800
Module Type Fieldbus Box I/O Module
Communication Interface RS485
Digital Inputs 4 channels (24 V DC)
Input Filter Time 0.2 ms
Digital Outputs 4 channels (24 V DC)
Max. Output Current 0.5 A per channel
Connection Technology M12 round connectors
Protection Class IP67
Shipping Weight 2.0 kg

Connections and Interfaces

Connection Type Connector Style Function
Fieldbus M12 RS485 Incoming and Outgoing lines
Digital Inputs M12 Channels 0 to 3 for 24 V DC sensors
Digital Outputs M12 Channels 0 to 3 for 24 V DC / 0.5 A actuators
Power Supply M8 / M12 24 V DC control voltage input and downstream feed

Installation Guidelines

  • Mounting: Secure the module directly to the machine frame or flat surfaces using the integrated mounting holes. Ensure the mounting surface is clean and level.
  • Grounding: Connect the functional ground (FE) directly to the machine potential via low-resistance grounding straps.
  • Torque Spec: Hand-tighten all M12 and M8 connections, then apply the specified torque of 0.6 Nm using an industrial torque wrench to maintain the IP67 protective seal.
  • Cabling: Keep signal and communication cables separate from high-voltage AC lines to prevent electromagnetic interference.

Compliance and Certifications

  • CE
  • UL

What is the primary function of the Beckhoff IP2312-B800?

The IP2312-B800 is a decentralized fieldbus box that connects 4 digital inputs and 4 digital outputs directly to an RS485 network in harsh IP67-rated environments.

What is the current rating for the digital outputs on this module?

Each digital output channel can source up to 0.5 A at 24 V DC.

What is the response or filter time for the digital inputs?

The module has a built-in input filter time of 0.2 ms for fast and accurate signal processing.

Does this module require an additional control enclosure?

No, because the IP2312-B800 is IP67 rated, it can be mounted directly on machinery without an external control cabinet.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...