BECKHOFF

BECKHOFF IP4132-B200 Fieldbus Box

SKU IP4132-B200

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP4132-B200
  • Origin Germany
  • Product Type: Fieldbus Modules
  • Payment: T/T, Western Union
  • Weight: 0.25 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Designed for decentralized industrial automation environments, the IP4132-B200 serves as a high-performance Fieldbus Box interface module utilizing optical fiber technology. This module enables direct connection of decentralized digital and analog peripheral signals to a controller via the Beckhoff Lightbus system, minimizing wiring overhead and signal interference over long distances.

Housed in an extremely robust, fully encapsulated enclosure, the IP4132-B200 is engineered for installation directly on machinery without the need for an electrical control cabinet. Its integrated fiber-optic transceiver interface provides outstanding noise immunity, making it ideal for high-EMI industrial environments. Configuration and diagnostics are easily managed through the standard KS2000 software tool or directly via the system PLC controller.

Features

  • High-speed fiber-optic communication with data transfer rates up to 2.5 Mbaud.
  • Lightbus system connection using 2 x fiber-optic sockets designed for ZS1020-0010 plugs.
  • Robust IP65, IP66, and IP67 protection ratings for reliable performance in harsh conditions.
  • M8 connector system for clean, daisy-chained control voltage distribution.
  • Electrical isolation between the control voltage and the internal fieldbus electronics.

Applications

  • Automotive manufacturing and assembly lines.
  • High-EMI environments such as welding cells and power distribution areas.
  • Material handling and packaging machinery.
  • Decentralized process control and factory automation.

Technical Specifications

Manufacturer BECKHOFF
Model / Part Number IP4132-B200
Fieldbus Interface 2 x fiber-optic socket for plug ZS1020-0010
Data Transfer Rate 2.5 Mbaud
Control Voltage 24 V DC (-15% / +20%)
Power Connection Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin
Electrical Isolation Control voltage to fieldbus: Yes
Protection Rating IP65/66/67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Weight approx. 250 g
Configuration Options Via KS2000 tool or the controller

Connections and Interfaces

Connector / Port Type Function
Bus Connection 2 x Fiber-optic sockets Lightbus network connection (IN / OUT)
Power Input (Feed) 1 x M8 male, 4-pin 24 V DC Control voltage supply input
Power Output (Downstream) 1 x M8 female, 4-pin Loop-through 24 V DC control voltage to downstream modules

Installation Guidelines

  • Fiber-Optic Handling: Maintain the specified minimum bending radius for fiber-optic cables to prevent signal loss or mechanical failure. Ensure the plug faces are clean before insertion.
  • Mounting: The module can be mounted in variable positions. Use flat mounting surfaces to avoid mechanical strain on the enclosure.
  • Environmental Sealing: Install protective sealing caps on all unused M8 ports and fiber-optic sockets to preserve the IP67 protection rating.

Compliance and Certifications

  • CE
  • UL
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Which fieldbus network does the Beckhoff IP4132-B200 support?
The IP4132-B200 connects to the Beckhoff Lightbus system, utilizing high-speed fiber-optic technology.
What is the data transmission rate of the IP4132-B200?
The module operates at a data transfer rate of 2.5 Mbaud.
Can this module be mounted directly in harsh industrial environments without a panel?
Yes, it features an IP65/66/67 rating, which fully protects it against dust, water spray, and temporary immersion, enabling cabinet-free installation.
How is the IP4132-B200 configured?
Configuration can be performed using the Beckhoff KS2000 software tool or directly via the higher-level PLC controller.
Reviews

IP4132-B200

Stock & lead time on request

Call
1 su 1

BECKHOFF IP4132-B200 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP4132-B200

  • Country of origin:Germany

  • Product Type: Fieldbus Modules

  • Payment: T/T, Western Union

  • Weight: 250g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Designed for decentralized industrial automation environments, the IP4132-B200 serves as a high-performance Fieldbus Box interface module utilizing optical fiber technology. This module enables direct connection of decentralized digital and analog peripheral signals to a controller via the Beckhoff Lightbus system, minimizing wiring overhead and signal interference over long distances.

Housed in an extremely robust, fully encapsulated enclosure, the IP4132-B200 is engineered for installation directly on machinery without the need for an electrical control cabinet. Its integrated fiber-optic transceiver interface provides outstanding noise immunity, making it ideal for high-EMI industrial environments. Configuration and diagnostics are easily managed through the standard KS2000 software tool or directly via the system PLC controller.

Features

  • High-speed fiber-optic communication with data transfer rates up to 2.5 Mbaud.
  • Lightbus system connection using 2 x fiber-optic sockets designed for ZS1020-0010 plugs.
  • Robust IP65, IP66, and IP67 protection ratings for reliable performance in harsh conditions.
  • M8 connector system for clean, daisy-chained control voltage distribution.
  • Electrical isolation between the control voltage and the internal fieldbus electronics.

Applications

  • Automotive manufacturing and assembly lines.
  • High-EMI environments such as welding cells and power distribution areas.
  • Material handling and packaging machinery.
  • Decentralized process control and factory automation.

Technical Specifications

Manufacturer BECKHOFF
Model / Part Number IP4132-B200
Fieldbus Interface 2 x fiber-optic socket for plug ZS1020-0010
Data Transfer Rate 2.5 Mbaud
Control Voltage 24 V DC (-15% / +20%)
Power Connection Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin
Electrical Isolation Control voltage to fieldbus: Yes
Protection Rating IP65/66/67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Weight approx. 250 g
Configuration Options Via KS2000 tool or the controller

Connections and Interfaces

Connector / Port Type Function
Bus Connection 2 x Fiber-optic sockets Lightbus network connection (IN / OUT)
Power Input (Feed) 1 x M8 male, 4-pin 24 V DC Control voltage supply input
Power Output (Downstream) 1 x M8 female, 4-pin Loop-through 24 V DC control voltage to downstream modules

Installation Guidelines

  • Fiber-Optic Handling: Maintain the specified minimum bending radius for fiber-optic cables to prevent signal loss or mechanical failure. Ensure the plug faces are clean before insertion.
  • Mounting: The module can be mounted in variable positions. Use flat mounting surfaces to avoid mechanical strain on the enclosure.
  • Environmental Sealing: Install protective sealing caps on all unused M8 ports and fiber-optic sockets to preserve the IP67 protection rating.

Compliance and Certifications

  • CE
  • UL

Which fieldbus network does the Beckhoff IP4132-B200 support?

The IP4132-B200 connects to the Beckhoff Lightbus system, utilizing high-speed fiber-optic technology.

What is the data transmission rate of the IP4132-B200?

The module operates at a data transfer rate of 2.5 Mbaud.

Can this module be mounted directly in harsh industrial environments without a panel?

Yes, it features an IP65/66/67 rating, which fully protects it against dust, water spray, and temporary immersion, enabling cabinet-free installation.

How is the IP4132-B200 configured?

Configuration can be performed using the Beckhoff KS2000 software tool or directly via the higher-level PLC controller.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...