Allen-Bradley 1794-IB16XT FLEX I/O Extended Temperature Digital Sinking Input Module

Allen-Bradley 1794-IB16XT FLEX I/O Extended Temperature Digital Sinking Input Module

Only 2 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1794-IB16XT

  • Country of origin:United States

  • Product Type: Digital Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 90g

  • Dimensions: 46 mm x 94 mm x 53 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The 1794-IB16XT is a ruggedized high-density discrete input module engineered for the FLEX I/O distributed network terminal platform. This specialized module functions as a 24V DC binary status processor, designed to monitor and translate digital signals from field sensing devices under extreme environmental conditions. Operating within a sinking current configuration, the internal electronics channel current from sourcing field-side switches through its sensing nodes to a centralized common return rail, maintaining clean status register processing across open control network systems.

As an XT (Extended Temperature) variant, this industrial hardware block incorporates resilient component architectures and factory conformal coating to withstand thermal shifts ranging from -20 to 70 Celsius. Armed with sixteen non-isolated channels, the device scales installation densities inside compact distributed control enclosures. The 1794-IB16XT executes data data routing back to master programmable logic controllers by communicating through standard network adapters over EtherNet/IP, ControlNet, or DeviceNet system buses. It is standard across oil and gas upstream stations, marine propulsion engine rooms, pipeline telemetry systems, and heavy mineral milling installations requiring continuous uptime in unconditioned environments.

Features

  • Extreme thermal performance scaling safely from -20 to 70 Celsius.
  • Factory applied conformal coating protecting internal substrates from moisture and airborne chemical agents.
  • Sixteen high-density discrete sinking inputs for maximum I/O count optimization per rail segment.
  • Removal and Insertion Under Power (RIUP) allowing live replacement without halting adjacent bus traffic.
  • Multi-point front-panel LED indicators providing visual diagnostic logging of individual channel logic states.

Applications

  • Midstream pipeline pumping station switch monitoring in unconditioned field cabinets.
  • Offshore drilling infrastructure emergency status and valve position tracking.
  • Heavy machinery mining excavations subject to high ambient thermal fluctuations.
  • Outdoor water treatment wastewater aeration station control loops.

Technical Specifications

Parameter Specification
Manufacturer Rockwell Automation / Allen-Bradley
Brand FLEX I/O XT
Part Number 1794-IB16XT
Module Type Extended Temperature Digital Sinking Input Module
Number of Inputs 16 Channels, Non-Isolated
Nominal Input Voltage 24V DC
On-State Voltage Range 10V DC to 31.2V DC
On-State Current Range 2.0 mA minimum to 12.0 mA maximum
Nominal On-State Current 8.0 mA at 24V DC
Off-State Voltage Maximum 5.0V DC
Off-State Current Maximum 1.5 mA
Nominal Input Impedance 4.6 kilohms
FlexBus Current Draw 30 mA at 5V DC
Continuous Isolation Voltage 50V (Basic Insulation Type)
Input Filter Time (On to Off) Programmable (0.25 ms nominal to 8.0 ms maximum)
Operating Temperature -20 to 70 degC
Storage Temperature -40 to 85 degC
Relative Humidity 5% to 95% non-condensing
Coating Protection Factory Conformal Coated PCB Assemblies
Country of Origin USA
Weight 0.09 kg
Dimensions 46 mm x 94 mm x 53 mm

Connections/Interfaces

Terminal Connection Block Node Function / Signal Path Allocation
Terminal 0 to Terminal 15 Extended Temperature Sinking Input Channels 0 through 15
+V (External Supply Node) 24V DC Sourcing Sensor Operational Power Distribution Path
COM (External Supply Return) Common Direct Current System Ground Reference Rail

Installation Guidelines

DIN Rail Installation

Engage the upper retention hooks of the rear module housing onto the top track flange of standard 35 mm DIN rail lines. Push down and pivot the bottom portion of the enclosure inward until the embedded steel latch assembly locks around the lower tracking rail lip.

Terminal Base Seating

Align the integrated physical guide tracks located on the bottom face of the operational module with the receiving key slots on the pre-installed conformal coated terminal base unit. Slide the hardware firmly into the interface socket matrix until the dual side latches click outwards to lock it in place.

Sinking Configuration Wiring

Wire external sourcing components directly to input points 0 through 15. Run the primary positive 24V DC distribution leg through the matching power tier of the terminal base block to keep standard potential profiles common across all connected sensor nodes.

Thermal Integrity Management

Ensure ambient air circulation pathways are completely free of structural debris within the enclosure. Maintain the factory minimum 50 mm clearance boundaries above and below the terminal assembly rail to enable convective cooling under high ambient operating profiles.

FAQ

What makes this module different from the standard 1794-IB16 model?

The unit features an extended operating temperature threshold (-20 to 70 Celsius) and integrated conformal coating on the internal circuit structures for hazardous environment deployment.

Does this hardware module require a specific terminal base assembly?

Yes, it should be paired with extended temperature or conformal coated terminal base units like the 1794-TB3K or 1794-TB3SK to maintain system environmental compliance.

What does the sinking circuit designation require from physical field components?

The sinking input path requires external devices to function as current sourcing components, supplying 24V DC into the input terminals.

Can this component be pulled from the rail during system runtime?

Yes, it supports removal and insertion under power, enabling live replacement without interrupting power or communication data blocks on the remainder of the rail.

Are the input channels protected against high-frequency electrical contact bounce?

Yes, the input filter time constant can be adjusted via the master system programming software to filter out noise from noisy mechanical switch elements.

What parameters determine a true off-state logic condition?

The channel registers an off-state when the voltage drops below 5.0V DC or the incoming input current drops under 1.5 mA.

Is separate external power required to drive the field sensory loops?

Yes, a nominal 24V DC external operational loop must be connected directly to the terminal base block to drive the field-side input tracking mechanisms.

What do the front-facing light-emitting diode indicators communicate?

The individual yellow lights illuminate when the corresponding input channel senses an active on-state voltage parameter.

Can this specific assembly process input data from alternating current circuits?

No, this unit is engineered exclusively to track low-voltage direct current values within a 10V DC to 31.2V DC window.

How does this module map its data bits back to a ControlLogix rack?

The hardware passes binary status values across the local FlexBus backplane to a communication adapter, which then transmits the data registers across the factory network.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...