1 of 1

Beckhoff CX5020-0125 CX Series Embedded PC CPU Module

Beckhoff CX5020-0125 CX Series Embedded PC CPU Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: CX5020-0125

  • Country of origin:Germany

  • Product Type: CPU Modules

  • Payment: T/T, Western Union

  • Weight: 575g

  • Dimensions: 106 mm x 100 mm x 92 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed to deliver robust and deterministic control for medium-sized automation systems, the CX5020-0125 Embedded PC is a compact, DIN rail-mountable controller featuring a 1.6 GHz Intel Atom® Z530 processor. This hardware unit functions as a high-density PLC and motion controller, executing complex control tasks through integrated software runtimes. It is engineered with automatic bus recognition, allowing direct physical connection and communication with both Beckhoff K-bus terminals and high-speed EtherCAT E-bus systems.

The unit incorporates comprehensive connectivity interfaces directly on its compact housing, minimizing the footprint within industrial control enclosures. It includes dual independent Gigabit Ethernet ports, multiple USB 2.0 interfaces, and a dedicated DVI-D output for direct human-machine interface (HMI) connection. To ensure high data integrity during unplanned power losses, the CX5020-0125 is equipped with an integrated 1-second UPS that writes persistent variables to an exchangeable Compact Flash card.

Features

  • Single-core Intel Atom® Z530 processor operating at 1.6 GHz clock speed.
  • Automatic physical bus detection supporting both E-bus (EtherCAT) and K-bus terminal connections.
  • Integrated hardware-based 1-second UPS protecting up to 1 MB of critical data on the Compact Flash card.
  • Fanless configuration utilizing passive convective cooling for extended operational longevity.
  • Comprehensive onboard interfaces: 2 x RJ45 Gigabit Ethernet, 4 x USB 2.0, and 1 x DVI-D.
  • Diagnostics LED cluster providing real-time feedback on power status, TwinCAT status, flash card access, and bus communication.

Applications

  • Distributed PLC and decentralized motion control in packaging and assembly plants.
  • Process control systems requiring reliable industrial communication networks.
  • Power generation and substation monitoring using standard industrial Ethernet protocols.
  • Building automation and environmental control systems with localized visual feedback.

Technical Specifications

ManufacturerPart Number/ModelProcessorMain MemoryFlash MemoryPersistent MemoryOperating SystemControl SoftwareTwinCAT 3 Platform LevelI/O Connection TypeI/O Current SupplyPower Supply VoltagePower ConsumptionOperating TemperatureStorage TemperatureRelative HumidityIP RatingVibration/Shock ResistanceEMC CompatibilityDimensions (W x H x D)Weight
Beckhoff
CX5020-0125
Intel Atom® Z530, 1.6 GHz (Single Core)
512 MB RAM (expandable ex factory to 1 GB)
Compact Flash card slot (128 MB card included, expandable)
Integrated 1-second UPS (1 MB of persistent data written to CF card)
Windows Embedded CE 6 or Windows Embedded Standard 2009
TwinCAT 2 runtime, TwinCAT 3 runtime (XAR)
Performance (40)
E-bus (EtherCAT) or K-bus (automatic recognition)
2 A (E-bus/K-bus)
24 V DC (-15% / +20%)
13 W (maximum)
-25 degC to +60 degC
-40 degC to +85 degC
95%, non-condensing
IP20
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 (Immunity) / EN 61000-6-4 (Emission)
106 mm x 100 mm x 92 mm
Approx. 575 g

Connections and Interfaces

NetworkVideoUSBI/O CouplerExpansion
Interface Type Specification / Connection Count
2 x RJ45 (10/100/1000 Mbit/s, independent)
1 x DVI-D port
4 x USB 2.0 ports
Integrated direct connection to Beckhoff terminal bus
1 x Slot for optional interfaces (factory configurable)

Installation Guidelines

  • Mount the module horizontally on a standard 35 mm DIN rail (EN 60715) inside a closed control cabinet.
  • Ensure a minimum clearances of 30 mm above and below the device to allow adequate convection airflow through the cooling ribs.
  • Verify that the mounting rail is connected to the functional earth of the cabinet before applying power.
  • Insert or remove the Compact Flash card only when the power supply to the controller is fully switched off to prevent data corruption.

Compliance and Certifications

  • CE, UL
  • ATEX: II 3 G Ex nA IIC T4 Gc (only applicable when configured with CX1900-0105 ordering option)

Does the CX5020-0125 require a cooling fan?

No, the CX5020-0125 uses a passive convection design and operates fanless when mounted in the recommended horizontal orientation with proper clearance.

How does the integrated 1-second UPS operate?

The module contains a capacitive reserve that provides power for approximately one second during a power outage. This provides sufficient time for the control software to save persistent variables to the Compact Flash card.

Can I connect both K-bus and E-bus terminals directly to this controller?

Yes, the controller has an automatic recognition feature that detects which type of terminal bus (EtherCAT E-bus or standard K-bus) is attached and configures communication accordingly.

What software runtimes are compatible with the CX5020-0125?

The CX5020-0125 is compatible with both TwinCAT 2 runtime and TwinCAT 3 runtime (XAR) platform level Performance (40).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...