1 of 1

BECKHOFF ELX3152-0090 EtherCAT Terminal

BECKHOFF ELX3152-0090 EtherCAT Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: ELX3152-0090

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 60g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Directing high-precision analog measurements in hazardous environments, the ELX3152-0090 is an intrinsically safe analog input terminal designed for the direct integration of field devices from Zone 0/20 explosion-hazard areas. This 2-channel single-ended interface processes standard 0/4 to 20 mA current signals with 16-bit resolution. Integrated with TwinSAFE SC (Single Channel) technology, the terminal enables safety-supporting signals to be analyzed and utilized within standard industrial control systems, expanding diagnostic depth and process safety across complex control architectures.

Features

  • Direct connection of intrinsically safe field devices from Zone 0/20 and Zone 1/21.
  • Two independent single-ended analog input channels supporting 0 to 20 mA and 4 to 20 mA signals.
  • TwinSAFE SC capability for integrating safety-assisting monitoring functions.
  • High-resolution 16-bit representation for highly accurate field instrument monitoring.
  • Supports Distributed Clocks (DC) for highly synchronized and precise EtherCAT process data acquisition.
  • Advanced internal processing options including activatable digital FIR/IIR filters.
  • Diagnostic compliance with NE43 NAMUR sensor limit specifications.

Applications

  • Oil and gas extraction, processing, and refining facilities.
  • Chemical and petrochemical process plants requiring intrinsic safety (Ex i).
  • Industrial wastewater treatment facilities with explosive gas atmospheres.
  • Pharmaceutical processing lines managing volatile substances.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model ELX3152-0090
Product Type EtherCAT Terminal (Ex i, TwinSAFE SC)
Number of Inputs 2 (single-ended)
Signal Current Range 0/4...20 mA
Connection Technology 2- or 3-wire (default: 3-wire)
Resolution 16 bit (including sign)
Measuring Error < +/-0.3% (relative to full scale value)
Internal Measuring Resistance typ. 100 Ohm
Input Filter Limit Frequency 5 kHz
Conversion Time typ. 1 ms
Electronics Supply Voltage 24 V DC (via power contacts, powered by ELX9560)
Current Consumption (Power Contacts) typ. 10 mA + load
Current Consumption (E-bus) typ. 85 mA
Distributed Clocks (DC) Yes
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Weight approx. 60 g
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Housing Material Polycarbonate

Connections and Interfaces

Connection Property Specification / Wire Size
Wiring Type Solid wire, stranded wire, or wire with ferrule (spring-actuated)
Solid Conductor (s) 0.08 to 2.5 mm² (AWG 28...14)
Stranded Conductor (st) 0.08 to 2.5 mm² (AWG 28...14)
Flexible Conductor with Ferrule (f) 0.14 to 1.5 mm² (AWG 26...16)
Stripping Length 8 to 9 mm
Power Contacts 2 blade/spring contacts

Installation Guidelines

  • Mount securely on a standard 35 mm DIN rail conforming to EN 60715 using the locking mechanism.
  • Ensure adjacent terminal modules are locked using the integrated double-slot and key housing connections.
  • Power the terminal exclusively through a certified ELX9560 power supply module to satisfy all intrinsically safe electrical isolation standards.
  • Ensure appropriate spacing and ventilation within the terminal cluster as defined by the hazardous zone class regulations.

Compliance and Certifications

  • CE, UL
  • ATEX: II 3(1)G Ex ec [ia Ga] IIC T4 Gc, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
  • IECEx: Ex ec [ia Ga] IIC T4 Gc, [Ex ia Da] IIIC, [Ex ia Ma] I
  • cFMus: AIS Class I, II, III, Division 1, Groups A-G; Class I, Division 2, Groups A-D; Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc

What is the primary function of the Beckhoff ELX3152-0090?

The Beckhoff ELX3152-0090 is a 2-channel analog input EtherCAT Terminal that allows direct measurement of 0/4 to 20 mA current loops from intrinsically safe (Ex i) sensors located in Zone 0/20 and Zone 1/21 hazardous areas.

What is TwinSAFE SC technology and how is it used in this module?

TwinSAFE SC (Single Channel) technology allows analog process values from standard terminals like the ELX3152-0090 to be made available to safety-related networks (TwinSAFE) for auxiliary safety functions, without requiring dedicated, certified safety-only hardware.

What power supply is required for the ELX3152-0090 terminal?

The terminal requires 24 V DC power delivered via the power contacts from an ELX9560 power supply terminal. This ensures compliance with intrinsically safe barrier regulations and appropriate signal isolation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

OpenVMS Alpha жүйесінде жұмыс істейтін Bailey INFI 90 Symphony HMI-лерін жаңарту

OpenVMS Alpha жүйесінде жұмыс істейтін ескірген Bailey Symphony операторлық станцияларын ауыстыруға арналған практикалық нұсқаулық. Ол Alpha эмуляциясын, OpenVMS x86-ға көшіруді, OPC қайта...

Өнеркәсіптік сенімділік үшін техникалық қызмет көрсету деректері неге маңызды

Техникалық қызмет көрсету деректері жұмыс тапсырыстарын, сенсор сигналдарын, активтердің тарихын, шығындарды және техник мамандардың білімін байланыстырады. Оны дұрыс қолдану жоспарлауды,...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...