1 of 1

BECKHOFF EP2816-0004 EtherCAT Box Digital Output Module

BECKHOFF EP2816-0004 EtherCAT Box Digital Output Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EP2816-0004

  • Country of origin:Germany

  • Product Type: EtherCAT Boxes

  • Payment: T/T, Western Union

  • Weight: 165g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for decentralized automation tasks in harsh environments, the Beckhoff EP2816-0004 is a high-density digital output module that interfaces directly with the EtherCAT network. This fieldbus-level device features 16 digital channels packaged in a compact, IP67-rated housing. It is engineered to switch binary control signals from the automation controller to actuators, solenoids, or indicators on the machine. By utilizing an M16, 19-pin output connector, the EP2816-0004 provides a centralized wiring point, making it highly compatible with multi-pin connector valve terminals.

The module operates on a nominal 24 V DC control voltage and handles up to 0.5 A per output channel. Each channel is designed with individual short-circuit protection to protect local wiring and system backplanes from overcurrent faults. With integrated support for Distributed Clocks, this EtherCAT Box guarantees highly synchronized signal processing across industrial installations.

Features

  • 16 digital output channels in a robust, space-saving design.
  • Centralized M16 19-pin output connector, optimizing connection to multi-pin valve manifolds.
  • Short-circuit proof outputs rated at 0.5 A per channel (total sum current of 4 A).
  • High-speed switching times with a typical turn-on time of 25 us and turn-off time of 50 us.
  • Distributed Clocks integration ensures precise synchronization with the central PLC controller.
  • Rugged IP65/66/67 construction enables direct machine mounting without an electrical enclosure.

Applications

  • Pneumatic valve terminal integration in industrial packaging lines.
  • Decentralized control of solenoids and actuators in automotive assembly.
  • On-machine I/O distribution for manufacturing machinery with limited enclosure space.
  • Water treatment facilities and process control operations requiring high environmental resistance.

Technical Specifications

ManufacturerPart Number / ModelProtocolBus InterfaceNumber of OutputsOutput ConnectionsLoad TypeNominal Output VoltageMax. Output CurrentSwitching TimesShort-Circuit CurrentDistributed ClocksCurrent Consumption from USAuxiliary Power CurrentPower Supply ConnectionElectrical IsolationOperating TemperatureStorage TemperatureVibration / Shock ResistanceEMC Immunity / EmissionProtection RatingWeight
Beckhoff
EP2816-0004
EtherCAT
2 x M8 socket, shielded, screw type
16
M16 socket, 19-pin
Ohmic, inductive, lamp load
24 V DC (-15% / +20%)
0.5 A per channel (individually short-circuit proof), sum max. 4 A
typ. T_ON: 25 us, typ. T_OFF: 50 us
max. 1.5 A
Yes
120 mA
typ. 20 mA + load
Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
500 V
-25 to +60 degC
-40 to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP65 / IP66 / IP67 (conforms to EN 60529)
approx. 165 g

Connections and Interfaces

Interface Type Connector Style Function
EtherCAT Bus 2 x M8 socket, shielded Inbound and outbound industrial Ethernet communications
Digital Outputs 1 x M16, 19-pin socket Unified connection for 16 digital control channels
Power Feed 1 x M8 male socket, 4-pin Primary 24 V DC supply input (US/UP)
Power Downstream 1 x M8 female socket, 4-pin Power pass-through to daisy-chained EtherCAT Box modules

Installation Guidelines

  • Mount the module directly to the machine frame or mounting plate using appropriate M3 screws. Ensure the mounting surface is flat to prevent mechanical stress on the housing.
  • To maintain the IP67 protection rating, ensure all unused M8 and M16 connectors are sealed with corresponding protective caps.
  • Establish a reliable ground connection via the metal mounting surface or the functional earth connection point on the module.
  • Observe the maximum allowable sum current of 4 A across all 16 channels to prevent internal power path overload.

Compliance and Certifications

  • CE
  • UL

What is the primary benefit of the M16 19-pin connection on the EP2816-0004?

The M16 19-pin connection consolidates all 16 digital output channels into a single physical interface. This layout is ideal for wiring directly to multi-pin connector valve terminals, minimizing individual cable routing and labor.

What is the total maximum output current supported by the EP2816-0004?

While each individual channel can drive up to 0.5 A, the total sum current across all 16 channels must not exceed 4 A.

Does the EP2816-0004 support precise synchronization across an EtherCAT network?

Yes, this module supports Distributed Clocks, ensuring highly synchronized signal switching matching the requirements of precise automation systems.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...