BECKHOFF EP4378-1022 EtherCAT Box I/O Module

BECKHOFF EP4378-1022 EtherCAT Box I/O Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EP4378-1022

  • Country of origin:Germany

  • Product Type: EtherCAT Boxes

  • Payment: T/T, Western Union

  • Weight: 250g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for decentralized automation tasks, the EP4378-1022 accommodates high-density digital and analog signals within a ruggedized, field-mountable housing. This Beckhoff EtherCAT Box serves as a versatile combination module, integrating 8 digital inputs, 8 digital outputs, 4 analog inputs, and 4 analog outputs. By providing comprehensive I/O capabilities directly on the machine, it eliminates the requirement for protective control cabinets and complex terminal boxes.

The analog channels on the module are highly adaptable, supporting both current and voltage modes (-10/0 to +10 V or -20/0/4 to +20 mA) customizable per individual channel at a precise 16-bit resolution. Built-in M12 connector interfaces ensure sealed, vibration-resistant connections under demanding industrial conditions, drastically reducing field wiring complexity and installation time.

Features

  • Combination module with 8 digital inputs/outputs and 4 analog inputs/outputs.
  • Parameterizable analog signals (voltage or current) configurable per channel.
  • High 16-bit resolution for precise analog-to-digital and digital-to-analog signal processing.
  • Direct field installation with IP65, IP66, and IP67 ingress protection ratings.
  • Dual M8 shielded, screw-type socket interfaces for high-speed EtherCAT communication.
  • Integrated actuator supply derived from the auxiliary voltage UP (short-circuit proof).
  • Electrical isolation of 500 V to isolate external field potentials from the EtherCAT network.

Applications

  • Decentralized field instrumentation and sensor arrays in assembly plants.
  • Machine tool control and localized factory automation networks.
  • Process control systems in wet, dusty, or demanding industrial environments.
  • Material handling systems requiring high-density localized I/O routing.

Technical Specifications

ManufacturerPart Number / ModelProtocolBus InterfaceNumber of Digital I/ONumber of Analog I/OI/O ConnectionsSignal TypeResolutionConversion TimeMeasurement UncertaintyOutput LoadInput Internal ResistanceActuator SupplyCurrent Consumption from USPower Supply ConnectionElectrical IsolationWeightOperating TemperatureStorage TemperatureProtection RatingVibration/Shock ResistanceEMC Immunity/Emission
BECKHOFF
EP4378-1022
EtherCAT
2 x M8 socket, shielded, screw type
8 x inputs, 8 x outputs
4 x inputs, 4 x outputs
M12 x 1, 5-pin, a-coded
-10/0 to +10 V | -20/0/4 to +20 mA (parameterizable per channel)
16 bit
Input: ~100 us, Output: ~40 us
Input: < 0.3%, Output: < 0.1% (relative to full scale value)
Voltage mode: > 5 kOhm | Current mode: < 350 Ohm
Voltage mode: > 200 kOhm | Current mode: typ. 85 Ohm + diode voltage
From auxiliary voltage UP, max. 0.5 A (total short-circuit proof)
120 mA
Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin
500 V
approx. 250 g
-25 to +60 degC
-40 to +85 degC
IP65/66/67 (conforms to EN 60529)
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Connector Type Interface Style Function Description
EtherCAT Bus 2 x M8 socket, shielded, screw type Inbound and outbound industrial Ethernet communications
I/O Channels M12 x 1, 5-pin, a-coded Direct connection for analog and digital field sensors/actuators
Power Feed 1 x M8 male socket, 4-pin Input power supply feed (US and UP lines)
Power Downstream 1 x M8 female socket, 4-pin Loop-through supply connection for downstream EtherCAT modules

Installation Guidelines

  • Mount securely to an industrial machine frame or mounting plate using the integrated screw holes. Installation is permitted in variable positions.
  • Ensure all mating M8 and M12 connectors are tightened to the recommended torque specifications to maintain the IP65/66/67 physical seal.
  • Route signal and EtherCAT cables separately from high-voltage AC power lines to prevent electromagnetic interference.
  • Ground the device using the designated connection point to safeguard communication integrity in electrically noisy environments.

Compliance and Certifications

  • CE
  • UL

What is the physical protection rating of the Beckhoff EP4378-1022?

The EP4378-1022 features an IP65/66/67 protection rating (conforming to EN 60529), making it completely dust-tight and resistant to water jets and temporary immersion, enabling direct installation in harsh field environments without an enclosure.

Can the analog channels be individually configured for different signal types?

Yes, each of the 4 analog inputs and 4 analog outputs is parameterizable individually for either voltage (-10/0 to +10 V) or current (-20/0/4 to +20 mA) depending on your field device requirements.

What is the resolution and conversion speed for the analog channels?

The module operates with a high 16-bit resolution. The signal conversion time is approximately 100 microseconds for inputs and 40 microseconds for outputs.

How is power distributed to downstream EtherCAT Box modules?

The module features a 4-pin M8 male power inlet for the feed, and a 4-pin M8 female socket for downstream connection, allowing you to daisy-chain the power supply (US/UP) to adjacent modules.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...