1 of 1

Beckhoff EPP1816-0008 EtherCAT P Box Digital Input Module

Beckhoff EPP1816-0008 EtherCAT P Box Digital Input Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EPP1816-0008

  • Country of origin:Germany

  • Product Type: Digital Input Modules

  • Payment: T/T, Western Union

  • Weight: 165g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for decentralized automation tasks in rugged environments, the EPP1816-0008 EtherCAT P Box acquires binary control signals from the physical process level and transmits them with high speed and synchronization to the control system. The unit is equipped with 16 digital inputs configured in a highly dense arrangement, accessible via a standard 25-pin D-sub interface.

Operating as an EtherCAT P device, this module integrates both ultra-fast EtherCAT communication and power distribution (for both system/sensor supply Us and peripheral voltage Up) into a single, specialized cable. The inputs conform to the EN 61131-2 Type 1 and Type 3 electronic standards, ensuring broad compatibility with 2-wire and 3-wire proximity sensors, limit switches, and photoelectric sensors. Built-in Distributed Clocks functionality guarantees precise latching of input states relative to the master system time.

Features

  • 16 digital input channels packaged in a compact, field-mountable form factor.
  • Unified EtherCAT P interface integrating power and signal on P-coded M8 connectors.
  • Concentrated sensor connection via a 25-pin D-sub socket with UNC4-40 locking threads.
  • Short-circuit proof, integrated sensor supply derived directly from the Us control voltage.
  • Hardware-supported Distributed Clocks for microsecond-precise input sampling.
  • IP67-rated enclosure allowing mounting outside electrical control cabinets.

Applications

  • High-density sensor data acquisition in assembly and packaging machinery.
  • Decentralized input mapping in conveyor and material handling systems.
  • Automated production lines requiring field-level modular expansions.
  • Machine tool control and robotics end-of-arm tool feedback integration.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Part Number / Model EPP1816-0008
Protocol EtherCAT P
Bus Interface 2 x M8 socket, shielded, screw type, P-coded
Number of Inputs 16
Input Connection D-sub socket, 25-pin, UNC4-40
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter 10 us (microseconds)
"0" Signal Voltage -3 to +5 V (conforming to EN 61131-2, type 3)
"1" Signal Voltage 11 to 30 V (conforming to EN 61131-2, type 3)
Input Current Typically 3 mA (conforming to EN 61131-2, type 3)
Distributed Clocks Yes
Sensor Supply From Us control voltage, max. 0.5 A total, short-circuit proof
Current Consumption from Us Typically 100 mA
Electrical Isolation 500 V
Weight Approx. 165 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Installation Position Variable

Connections and Interfaces

Connector Interface Type Function
EtherCAT P Input M8, 4-pin socket, P-coded EtherCAT P incoming communication and power feed (Us, Up)
EtherCAT P Output M8, 4-pin socket, P-coded EtherCAT P downstream communication and power forwarding
Digital Inputs 25-pin D-sub socket (UNC4-40 thread) 16-channel input terminals, including sensor supply and GND

Installation Guidelines

  • Ensure the installation surface is flat and clean to guarantee a proper seal when mounting. Secure the housing using M3 screws through the integrated mounting holes.
  • Use only pre-assembled, shielded EtherCAT P cabling with P-coded M8 connectors to protect the physical layer and preserve the IP67 protection class.
  • When connecting sensors via the 25-pin D-sub interface, verify that the total load current drawn does not exceed the maximum sensor supply rating of 0.5 A.
  • Establish a reliable, low-impedance ground connection via the mounting profile or the designated grounding point on the module's body.

Compliance and Certifications

  • CE
  • UL

What connection interface is used for the digital inputs on the Beckhoff EPP1816-0008?

The digital inputs are concentrated on a single, high-density 25-pin D-sub socket equipped with UNC4-40 locking threads.

Does this module support Distributed Clocks (DC)?

Yes, the EPP1816-0008 features integrated Distributed Clocks, allowing highly precise and synchronized input latching across the EtherCAT network.

What is the maximum sensor supply current available from the module?

The module provides a short-circuit-proof sensor supply of up to 0.5 A in total, derived from the Us control voltage.

Can this EtherCAT P box be mounted in harsh environments without an enclosure?

Yes, it is rated IP65, IP66, and IP67 in compliance with EN 60529, making it suitable for direct field mounting outside electrical cabinets.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...