1 of 1

BECKHOFF IL2301-B310 Fieldbus Box Coupler Box

BECKHOFF IL2301-B310 Fieldbus Box Coupler Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IL2301-B310

  • Country of origin:Germany

  • Product Type: Fieldbus Coupler Boxes

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for decentralized industrial automation networks, the IL2301-B310 functions as a robust PROFIBUS DP coupler box within the Beckhoff Fieldbus Box range. This high-performance module serves as an IP-Link gateway, allowing standard decentralized extension modules to interface directly with a PROFIBUS DP fieldbus network. Built to operate in harsh machine-level environments, this coupler box eliminates the need for protective control cabinets by integrating advanced diagnostic functions and rugged hardware routing directly onto the machine frame.

The module automatically detects transfer rates up to 12 Mbaud and supports DP-V1 extensions, providing flexible integration options and precise parameterization via the Beckhoff KS2000 configuration software or the master PLC controller. This ensures optimal communication efficiency and minimal configuration overhead in complex multi-node network topologies.

Features

  • Automatic baud rate detection up to 12 Mbaud for seamless network integration.
  • Hardened industrial housing rated at IP65, IP66, and IP67 for direct wet and dusty environment placement.
  • Integrated IP-Link fiber-optic interface for high-speed localized system expansion.
  • Support for DP-V1 extensions enabling sophisticated parameterization and advanced diagnostic workflows.
  • Compact M12 interface for reliable PROFIBUS DP connection and minimized physical footprint.
  • M8 power supply design with upstream feed and downstream loop-through connections.

Applications

  • Automotive manufacturing and assembly lines.
  • High-speed packaging machinery and sorting systems.
  • Material handling conveyor systems.
  • Food and beverage production facilities requiring frequent high-pressure washdowns.

Technical Specifications

ManufacturerPart Number / ModelProduct SeriesFieldbus ProtocolData Transfer RatesConfiguration InterfaceFieldbus InterfaceTransmission MediumControl VoltageLoad VoltagePower Supply ConnectionsInternal Current ConsumptionOperating TemperatureStorage TemperatureVibration/Shock ResistanceEMC Immunity/EmissionIngress Protection RatingCertifications
Beckhoff Automation
IL2301-B310
Fieldbus Box (IP-Link Coupler)
PROFIBUS DP
Automatic detection up to 12 Mbaud
Via KS2000 software or master controller (DP-V1 supported)
1 x M12 socket, 5-pin, B-coded
Shielded copper cable, 2 x 0.25 mm2
24 V DC (-15% / +20%)
Dependent on connected I/O extension type
Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
85 mA + sensor load (max. 0.5 A)
0 to +55 degC
-25 to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP65, IP66, IP67 (conforms to EN 60529)
CE, UL

Connections and Interfaces

Connector / Interface Pin/Socket Type Function
PROFIBUS DP M12 Socket, 5-pin, B-coded Fieldbus communication link
Power Feed M8 Male, 4-pin 24 V DC control and load power input
Power Downstream M8 Female, 4-pin 24 V DC loop-through to adjacent modules
IP-Link Fiber-optic sockets Connection to Fieldbus Box extension modules

Installation Guidelines

  • Securely mount the module directly to the machinery frame or mounting plate using appropriate M4 screws.
  • Ensure all M12 and M8 protective caps or cables are fully tightened to a torque specified for IP67 compliance.
  • Maintain a minimum bending radius for the IP-Link fiber-optic connection cables to avoid signal degradation.
  • Use shielded, twisted-pair copper cables for PROFIBUS connections to protect against electromagnetic interference.

What is the primary function of the Beckhoff IL2301-B310?

The Beckhoff IL2301-B310 is a PROFIBUS DP coupler box that acts as a decentralized gateway, linking localized IP-Link extension I/O modules directly to a PROFIBUS DP fieldbus system.

Does the IL2301-B310 support DP-V1 extensions?

Yes, this coupler box fully supports DP-V1 extensions, allowing for advanced parameterization, configuration, and diagnostics via KS2000 software or the master controller.

What is the environmental rating of the IL2301-B310?

The module features an IP65, IP66, and IP67 protection rating, meaning it is dust-tight and resistant to high-pressure water jets, enabling direct machine-mount installations.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...