1 of 1

Beckhoff KL9505 Bus Terminal Power Supply Module

Beckhoff KL9505 Bus Terminal Power Supply Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL9505

  • Country of origin:Germany

  • Product Type: Power supply terminal 5 V DC

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The KL9505 is a 5 V DC power supply terminal designed to provide a regulated voltage for peripheral devices within the Beckhoff Bus Terminal system. This module converts a 24 V DC input into a stabilized 5 V DC output, ensuring reliable power delivery for sensitive electronics. It is engineered for industrial environments, featuring an integrated overcurrent LED for status monitoring and protection against short circuits.

Features

  • Stabilized 5 V DC output voltage
  • Integrated overcurrent monitoring with LED indicator
  • Short-circuit proof design
  • Pluggable wiring interface for KSxxxx series compatibility
  • Compact DIN rail mountable form factor

Applications

  • Powering auxiliary 5 V sensors or transducers
  • Local supply for communication interfaces
  • General-purpose low-voltage DC power distribution in automation cabinets

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model KL9505
Input Voltage 24 V DC (-15 %/+20 %)
Output Voltage 5 V DC ±1 %
Output Current 0.5 A
Residual Ripple < 5 mV
Short-Circuit Proof Yes
Weight Approx. 65 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, no condensation
Protection Rating IP20

Installation Guidelines

  • DIN Rail Mounting: The module is designed for standard DIN rail installation. Ensure it is securely clicked into place to maintain proper electrical contact with the bus system.
  • Wiring: Use pluggable wiring consistent with KSxxxx series requirements. Ensure correct polarity of the 24 V DC input supply.
  • Cooling: Maintain adequate clearance around the module to allow for natural convection cooling, especially when operating near the upper limit of the temperature range.
  • Protection: Adhere to local EMC regulations (EN 61000-6-2/EN 61000-6-4) during cable routing to minimize noise interference.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • Vibration/Shock: Conforms to EN 60068-2-6 / EN 60068-2-27

What is the primary function of the KL9505 terminal?

The KL9505 is a power supply terminal that converts a 24 V DC input into a stabilized 5 V DC output for use within the Beckhoff Bus Terminal system.

Does the module provide protection against short circuits?

Yes, the module is short-circuit proof and includes an integrated overcurrent LED to indicate fault conditions.

What is the maximum output current for this device?

The maximum output current for the KL9505 is 0.5 A.

What are the environmental operating limits for this module?

The module operates within a temperature range of 0 to +55 degC and supports up to 95% relative humidity without condensation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...