  • Manufacturer: Bently Nevada

  • Product No.: 143416-01

  • Country of origin:United States

  • Product Type: Proximitor Sensors

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 12.0 cm x 10.0 cm x 6.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Engineered for highly reliable proximity measurement within machine protection systems, the Bently Nevada 143416-01 processes eddy current signals from a 3300 XL 5mm or 8mm probe to deliver precise vibration and position telemetry. This high-precision sensor acts as a key signal conditioner, generating an analog voltage output directly proportional to the static or dynamic distance between the probe tip and the target shaft. Specifically calibrated for a 5.0-meter system length, the Bently Nevada 143416-01 ensures continuous, uninterrupted monitoring of critical rotating machinery in demanding industrial environments.

Features

  • Fully compatible with 3300 XL 5mm and 8mm proximity probes and extension cables.
  • Calibrated for a total physical system length of 5.0 meters to ensure accurate electrical scale factor output.
  • Robust resistance against radio frequency interference (RFI) and electromagnetic noise.
  • Provides a stable, high-fidelity linear output voltage relative to physical target gap variations.
  • Compact, durable package designed for standard DIN rail or high-density panel mounting.

Applications

  • Radial vibration and axial position monitoring of steam, gas, and hydro turbines.
  • Eccentricity and speed measurement on critical power generation machinery.
  • Shaft displacement tracking in high-speed industrial compressors and turboexpanders.
  • Rotor dynamics diagnostics in harsh chemical and petroleum processing plants.

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Model Number 143416-01
Product Series 3300 XL
Compatible Probes 3300 XL 5mm and 8mm Proximity Probes
System Length Calibration 5.0 Meters
Scale Factor 7.87 V/mm (200 mV/mil) Nominal
Supply Voltage Requirements -24 Vdc (Acceptable input range: -18 Vdc to -26 Vdc)
Current Consumption Less than 12 mA (Nominal)
Output Impedance 50 ohms
Operating Temperature -51 degC to +100 degC (-60 degF to +212 degF)
Storage Temperature -51 degC to +105 degC (-60 degF to +221 degF)
Country of Origin United States
Shipping Weight (Calculated) 0.25 kg (0.55 lbs)
Package Dimensions (Calculated) 12.0 cm x 10.0 cm x 6.0 cm

Connections and Interfaces

Terminal / Connector Function / Circuit Assignment
PROBE Coaxial Port Accepts subminiature coaxial connection from the 3300 XL extension cable.
VT Terminal Power Input (-24 Vdc supply connection relative to COM).
OUT Terminal Dynamic Analog Voltage Signal Output (proportional to target distance).
COM Terminal Common Ground Reference for power supply and signal return.

Empirical Engineering Insights

Alternative Models & Compatibility: The 143416-01 is explicitly tuned to a 5.0-meter system length. If your loop utilizes a 9.0-meter probe and extension cable arrangement, utilizing this sensor will severely skew output voltage calculations, requiring substitution with a 9.0-meter variant. Never mix 3300 XL series components with obsolete 7200 series sensors as impedance mismatches will compromise safety shutdowns.

Application Pitfalls & Engineering Notes: Because eddy current technology relies on the electromagnetic properties of the target material, any deviation from standard AISI 4140 steel targets requires custom calibration of the Proximitor to prevent major measurement errors. Always mount the unit within a secure weather-proof or explosion-proof enclosure if located near process streams to avoid housing erosion from corrosive gases.

Commissioning & Wiring Tips: Ensure the coaxial connection is fully tightened using only hand torque; over-tightening with hand tools can fracture the internal subminiature connector. For electrical noise isolation, wrap the coaxial connection boot with self-amalgamating insulation tape to prevent accidental shorting or grounding against adjacent conduit runs.

Installation Guidelines

CRITICAL WARNING: De-energize all connected power sources, monitoring racks, and adjacent high-voltage field devices before proceeding with physical or electrical installation. Verify zero voltage presence at the terminal block using a calibrated digital multimeter. Failure to follow industrial safety, lockout, and tagout protocols can lead to machine protection trips or system hardware damage.
1
Mount the 143416-01 Proximitor housing securely inside the instrument enclosure using standard 35mm DIN rail or direct panel mounting holes. Ensure proper physical clearance for clean routing of the probe cable and signal terminal connections.
2
Connect the 3300 XL extension cable to the Proximitor coaxial port. Route the field cable cleanly, observing the minimum bending radius of 25.4mm (1.0 in) to prevent internal physical degradation of the coaxial core.
3
Strip the signal field wiring (recommended 18 to 22 AWG shielded, twisted-pair wire) and connect to VT (-24 Vdc), OUT (Output signal), and COM (Common) terminals. Ensure the field wire shield is terminated only at the safety monitoring system or barrier ground.
4
Energize the loop and use a multimeter to measure the gap voltage between the COM and OUT terminals, adjusting probe depth in the machine bracket to verify the target is within the linear voltage range of the sensor.

What is the calibrated system length for the 143416-01 sensor?

This model is specifically designed and calibrated for a total system length of 5.0 meters. The total length of the coupled proximity probe and extension cable must equal 5.0 meters to maintain correct signal scale factor.

Which Bently Nevada probes are compatible with this Proximitor?

The sensor is compatible with standard Bently Nevada 3300 XL 5mm and 8mm proximity probes and their corresponding 5.0-meter extension cables.

What is the standard output scale factor of this eddy current sensor?

It provides a nominal linear output scale factor of 7.87 V/mm (200 mV/mil) when measuring a standard AISI 4140 steel target.

What power supply voltage is required for the 143416-01 Proximitor?

The Proximitor requires a negative DC supply voltage of -24 Vdc, with an acceptable operational range of -18 Vdc to -26 Vdc relative to the COM terminal.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...