1 of 1

Delta Electronics AHCPU530-RS2 AH Series CPU Module

Delta Electronics AHCPU530-RS2 AH Series CPU Module

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: AHCPU530-RS2

  • Country of origin:United States

  • Product Type: CPU Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 110 mm x 40 mm x 103 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

To manage complex industrial processes, the AHCPU530-RS2 serves as a highly reliable main processing unit within the Delta AH Series PLC system. This high-density CPU module delivers swift execution speeds of 0.1 microseconds for basic LD instructions, enabling rapid logic processing and real-time system coordination in demanding automation environments. Equipped with built-in multi-mode RS-232/422/485 ports and a Mini-USB programming interface, this controller facilitates seamless integration with human-machine interfaces, variable frequency drives, and supervisory control networks.

The system architecture supports a large control scale, handling up to 4,352 local I/O points and expanding across up to 7 extension backplanes. Program storage is secured via a 256K steps (1MB) program capacity, complemented by robust data registers and native support for multiple IEC 61131-3 programming languages, including Ladder Diagram (LD), Sequential Function Chart (SFC), Function Block Diagram (FBD), Instruction List (IL), and Structured Text (ST).

Features

  • High-speed logic processing: LD instruction execution at 0.1 microseconds (1K steps in 0.3 ms).
  • Substantial memory allocation: 256K steps program memory and 64K words data registers.
  • Integrated dual serial communication: Two multi-mode RS-232/422/485 ports supporting MODBUS RTU and ASCII protocols.
  • Broad system expansion: Supports up to 7 extension backplanes and a maximum of 4,352 local I/O points.
  • Built-in SD card interface: Supports standard SD cards up to 2GB for diagnostic logs and data backups.
  • Battery-free design: Built-in Real-Time Clock (RTC) function retains time for up to 30 days post power-down without a backup battery.

Applications

  • Power generation and distribution automation
  • Water and wastewater treatment infrastructure
  • HVAC and environmental control systems
  • Material handling, logistics, and high-speed assembly lines
  • Chemical and process manufacturing control

Technical Specifications

Manufacturer Delta Electronics
Model AHCPU530-RS2
Product Series AH Series
Module Type CPU Module
Program Capacity 256K steps (1 MB)
Local I/O Capacity 4,352 points
Data Register D / L / B 64K / 64K / 4096K words
Function Blocks Max. 1024
Extension Backplane Support Up to 7 backplanes
Power Consumption 2W (Internal)
Execution Speed 0.1 microseconds (LD instruction)
Built-in Ports 2 x RS-232/422/485, 1 x Mini-USB programming port
External Storage Support SD card slot (Max. 2 GB)
Timers and Counters 2048
Interrupts 256 (Timed, I/O, External, Low voltage, Communication)
Programming Languages LD, SFC, FBD, IL, ST
Dimensions (H x W x D) 110 mm x 40 mm x 103 mm
Shipping Weight 2 kg

Connections and Interfaces

Port / Interface Functional Description
COM1 / COM2 (Multi-mode) RS-232 (up to 115.2 kbps) / RS-422 and RS-485 (up to 921.6 kbps)
Mini-USB Dedicated local programming, configuration, and diagnostics interface
SD Slot Memory card expansion up to 2 GB for firmware, programs, or logs

Installation Guidelines

  • Backplane Installation: Mount the module securely onto the main AH series backplane, checking that the top and bottom latch connectors are fully locked.
  • Grounding: Connect the backplane's functional ground terminal directly to a clean, noise-free system earth.
  • Wiring: Route the RS-485 and communication lines away from high-voltage motor cables to prevent electromagnetic interference. Shielded cables are highly recommended.
  • Thermal Clearance: Maintain a minimum of 50 mm passive airflow gap above and below the CPU unit.

What is the maximum local I/O capacity supported by the AHCPU530-RS2?

The AHCPU530-RS2 CPU module supports a maximum local I/O capacity of up to 4,352 points when fully expanded.

Does this CPU module require a backup battery for real-time clock (RTC) retention?

No battery is required. The AHCPU530-RS2 features a battery-free design with a built-in RTC function that can retain time and system states for up to 30 days after power-off.

What programming languages are compatible with this AH Series controller?

The module is compatible with five IEC 61131-3 standard languages: Ladder Diagram (LD), Sequential Function Chart (SFC), Function Block Diagram (FBD), Instruction List (IL), and Structured Text (ST).

What is the execution speed of the AHCPU530-RS2 processor?

The program execution speed is 0.1 microseconds for basic LD instructions, processing approximately 1K steps in 0.3 milliseconds.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...