1 of 1

Delta VFD110B23B VFD-M Series Micro Drive

Delta VFD110B23B VFD-M Series Micro Drive

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: VFD110B23B

  • Country of origin:United States

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Delta VFD110B23B is a compact General Sensorless Vector Control Micro Drive from the established VFD-M series. Designed for space-saving and cost-effective motor control, this micro drive offers reliable performance for a wide range of industrial tasks. It is configured for a three-phase 230 V input and provides a flexible output frequency range from 0.1 to 400 Hz, making it suitable for both high-speed and precision-controlled applications.

The VFD-M series is known for its versatility, featuring both adjustable V/f curves and sensorless vector control modes. With a carrier frequency capability of up to 15 kHz, the VFD110B23B ensures quiet motor operation and reduced electrical noise, essential for integrated control environments. This drive provides a balanced solution for users requiring robust control in a small form factor.

Features

  • Series: VFD-M (General Sensorless Vector Control Micro Drive)
  • Input Voltage: Three-phase 230 V
  • Output Frequency: 0.1 to 400 Hz
  • Control Modes: Adjustable V/f curve and sensorless vector control
  • Switching Frequency: Carrier frequency up to 15 kHz
  • Design: Compact micro drive architecture
  • Efficiency: High-precision motor control for diverse industrial load profiles

Applications

  • Small conveyors and material handling
  • Fans and centrifugal pump control
  • Food processing and packaging machinery
  • Textile and woodworking equipment
  • General industrial speed regulation

Technical Specifications

Feature Specification
Manufacturer Delta
Model VFD110B23B
Series VFD-M
Product Type Micro Drive
Input Voltage Three-phase 230 V
Output Frequency 0.1 to 400 Hz
Control Method V/f curve / Sensorless vector control
Carrier Frequency Up to 15 kHz
Shipping Weight 3 kg

Installation Guidelines

  • Mounting: Mount the VFD-M drive in a vertical orientation within a clean, dry, and ventilated enclosure.
  • Thermal Management: Ensure sufficient air circulation around the heat sink to support the carrier frequency operation.
  • Wiring: Keep control signal lines separate from power cables to prevent electromagnetic interference (EMI).
  • Grounding: Connect the drive to a reliable protective earth (PE) terminal to ensure safety and signal stability.
  • Maintenance: Regularly inspect the cooling fan and clean the vents to prevent dust buildup, which can lead to thermal shutdown.

What is the output frequency range of the VFD110B23B?

The output frequency range is 0.1 to 400 Hz.

What control modes does this VFD-M drive support?

It supports both adjustable V/f curve control and sensorless vector control.

What is the maximum carrier frequency for this model?

The carrier frequency can be adjusted up to 15 kHz.

What power input is required for this specific model?

This drive requires a three-phase 230 V input.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
United States

Recently Viewed Products

Technical knowledge

OpenVMS Alpha жүйесінде жұмыс істейтін Bailey INFI 90 Symphony HMI-лерін жаңарту

OpenVMS Alpha жүйесінде жұмыс істейтін ескірген Bailey Symphony операторлық станцияларын ауыстыруға арналған практикалық нұсқаулық. Ол Alpha эмуляциясын, OpenVMS x86-ға көшіруді, OPC қайта...

Өнеркәсіптік сенімділік үшін техникалық қызмет көрсету деректері неге маңызды

Техникалық қызмет көрсету деректері жұмыс тапсырыстарын, сенсор сигналдарын, активтердің тарихын, шығындарды және техник мамандардың білімін байланыстырады. Оны дұрыс қолдану жоспарлауды,...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...