The Emerson PR6423/010-010 with CON021 is a non-contact sensor and signal converter system engineered for critical turbomachinery applications, including steam, gas, and hydro turbines, compressors, gearboxes, pumps, and fans. The PR6423 eddy current sensor detects radial and axial shaft dynamic displacement, position, eccentricity, and speed. The CON021 sensor signal converter processes these proximity measurements into stable output signals suitable for monitoring industrial machinery health.

Features

  • Non-contact eddy current measurement principle for precise displacement tracking
  • High-frequency response suitable for dynamic machine diagnostics
  • Armored cable protection for enhanced mechanical durability in industrial environments
  • Flexible mounting options with included installation screws
  • Transducer connection utilizing a self-locking plug interface

Applications

  • Radial and axial shaft dynamic displacement monitoring
  • Shaft position and eccentricity measurement
  • Speed monitoring and key pulse detection
  • Turbomachinery protection systems (turbines, compressors, fans, pumps)

Ordering Information

Model No. / Number Description
PR6423/01 Armored Cable: Yes, Case Threads: M10x1, Tip Diameter: 8mm, Case Thread X: 0 (25mm), Adapter Plug X: 0 (With), Cable Length X: 1 (5.0m), Cable End X: 0 (Lemo)
CON021 Sensor Signal Converter, Sensor Type: PR6423, Measuring Range: 2.0mm (Standard Range), Linearity Error: <= 1.0%

Technical Specifications

CON021 Signal Converter Specifications

Parameter Specification
Manufacturer Emerson
Frequency Range (-3 dB) 0 to 20000 Hz
Rise Time <15 us
Operating Temperature Range -30 to 100 degC (-22 to 212 Fahrenheit)
Shock and Vibration 5g @ 60 Hz @ 25 degC (77 Fahrenheit)
Protection Class IP20
Supply Voltage Range (-24V config) -23V to -32V (Output Range: -4V to -20V)
Supply Voltage Range (-2V config) -21V to -32V (Output Range: -2V to -18V)
Housing Material LMgSi 0.5 F22
Weight ~120 grams (4.24 oz)
Mounting Hardware 4 Screws M5x20

PR6423 Eddy Current Sensor Specifications

Parameter Specification
Tip Diameter 8mm
Case Threads M10x1
Armored Cable Yes
Linear Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils)
Incremental Scale Factor (ISF) ISO: 8 V/mm (203.2 mV/mil) +/-5% @ 0 to 45 degC
Deviation from Best Fit Straight Line (DSL) +/-0.025 mm (+/-1 mil) @ 0 to 45 degC
Minimum Shaft Diameter 25 mm (0.79 inch)
Target Material 42CrMo4 (AISI/SAE 4140) Standard
Protection Class IP66 (IEC 60529)
Sensor & 1m Cable Temperature -35 to +180 degC (-31 to 356 Fahrenheit)
Cable & Connector Temperature -35 to +150 degC (-31 to 302 Fahrenheit)
Material Sensor Tip: PEEK, Case: Stainless Steel, Cable: PTFE, Connector: Brass (nickel-plated)
Weight (Sensor with 1m Cable) Approx. 100 grams (3.53 oz)

Connections/Interfaces

Connector / Terminal Function
Transducer Input Self-Locking Lemo-Plug Interface
Supply / Output Terminals Screw Terminal Type (max. 1.5mm2 wire)

Installation Guidelines

  • Ensure the minimum bending radius for the standard cable is at least 25 mm, and at least 35 mm for the armored cable.
  • Maintain proper probe gap alignment using the target initial air gap specification of 0.5 mm for standard measurement ranges.
  • Mount the signal converter within an environment matching its IP20 rating, securing it firmly with the provided M5x20 screws.
  • Use a safety barrier or current limiting device when deploying the system into hazardous environments requiring intrinsic safety.

Compliance and Certifications

  • CE: 2014/30/EU (EN 61326-1), 2014/34/EU, 2011/65/EU, DIN EN 50581
  • ATEX: EN 60079-0, EN 60079-11 (II 2 G Ex ia IIC T4 Gb @ -20 degC <= Ta <= 80 degC)
  • IEC-Ex: IEC 60079-0, IEC 60079-11, IEC 60079-26 (Ex ia IIC T4 Gb @ -20 degC <= Ta <= 80 degC)
  • CSA: Class I Division 1, Groups A, B, C, D, T4 (-25 degC <= Ta <= 80 degC); Class I Division 2, Groups A, B, C, D Ex nA II T3..T4
  • Standards: ANSI/UL 913-2004, ANSI/UL 1604-1995, UL 60079-15 2002, UL 61010-1

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson PR6423/010-010 CON021 Eddy Current Sensor System

What is the linear measurement range of the sensor system?

The sensor system features a standard linear measurement range of 2.0 mm (80 mils) when paired with the standard converter configuration.

What type of electrical connections are used on the converter module?

The converter module utilizes a self-locking Lemo-plug for the transducer input connection and screw terminal type connections for the supply and output wiring.

What are the environmental protection ratings for the system components?

The eddy current sensor probe head holds an IP66 rating, while the signal converter housing is rated at IP20.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...