1 of 1

EPI2008-0002 | BECKHOFF | IO-Link Box Digital I/O Module

EPI2008-0002 | BECKHOFF | IO-Link Box Digital I/O Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EPI2008-0002

  • Country of origin:Germany

  • Product Type: IO-Link box

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The EPI2008-0002 is a robust IO-Link box from Beckhoff, designed to provide flexible and decentralized I/O connectivity in industrial environments. This module functions as an IO-Link V1.1 (Class B) device, featuring 8 digital inputs for high-density signal acquisition. It supports a data transfer rate of 230.4 kbaud (COM 3) and is engineered with an IP65/66/67 protection rating, making it suitable for direct field mounting without the need for an additional control cabinet.

Features

  • 8 digital inputs via M12 screw-type connectors
  • IO-Link communication (Specification V1.1, Class B)
  • Supports COM 3 (230.4 kbaud) data transfer rates
  • Individual short-circuit protection per channel (0.5 A max output)
  • High protection rating (IP65/66/67) for harsh environments
  • Electrical isolation between L+ and P24

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model EPI2008-0002
Communication IO-Link V1.1, Class B
Data Transfer Rate 230.4 kbaud (COM 3)
Interface 1 x M12 plug, A-coded
Number of Inputs 8
Nominal Input Voltage 24 V DC (-15 %/+20 %)
Max. Output Current 0.5 A per channel
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65/66/67
Weight Approx. 165 g

Installation Guidelines

  • Mounting: Due to its IP65/66/67 rating, this module can be mounted directly on machinery or in open field locations. Ensure the mounting surface is vibration-resistant according to EN 60068-2-6.
  • Connectivity: Use M12 A-coded cables for IO-Link communication and M12 screw-type connectors for the 8 digital inputs.
  • Power Supply: The module requires 24 V DC. Ensure current consumption (100 mA from L+ and 20 mA + load for auxiliary power) is within the specifications of your power distribution system.
  • Environment: While protected against dust and water (IP67), avoid mounting in areas where chemicals not compatible with the housing material might be present.

Compliance and Certifications

  • CE
  • UL
  • EMC: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Environmental: Conforms to EN 60529 (IP rating)

What is the IO-Link specification version of the EPI2008-0002?

The module complies with IO-Link V1.1, Class B specifications.

How many digital inputs are available on this module?

The module features 8 digital inputs using M12 screw-type connectors.

What protection rating does this IO-Link box have?

It is rated IP65/66/67, making it suitable for harsh industrial environments and direct field mounting.

What is the maximum output current per channel?

The module supports a maximum output current of 0.5 A per channel, with individual short-circuit proofing.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...