Honeywell 05704-A-0121 Quad Relay Interface Card

Honeywell 05704-A-0121 Quad Relay Interface Card

Only 4 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 05704-A-0121

  • Country of origin:United States

  • Product Type: Relay Interface Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell 05704-A-0121 is a high-reliability Quad Relay Interface Card designed to facilitate essential signal routing between field sensors and primary control cards. This interface module supports four individual channels, providing flexible control configurations through selectable relay operations. With its robust relay contact ratings and compact form factor, the 05704-A-0121 is ideal for industrial monitoring systems requiring precise, configurable sensor-to-controller interfacing.

Features

  • Quad-channel architecture: Supports connections for up to four sensors.
  • Configurable Relay Operation: Selectable between Latching/Non-Latching and Energized/De-energized states to suit specific system safety or logic requirements.
  • High-capacity relay contacts: Rated for 5A at 110V/250V AC or 32V DC (non-inductive).
  • Compact design: Optimized for standard control panel footprints with a width of 25 mm.

Applications

  • Industrial gas and flame detection systems
  • Sensor signal processing in safety-critical loops
  • PLC and DCS input interface management
  • Automated relay switching for alarm or shutdown circuits

Technical Specifications

Feature Specification
Manufacturer Honeywell
Part Number 05704-A-0121
Product Type Quad Relay Interface Card
Power Consumption 1W (typical) / 1.7W (maximum)
Relay Configuration 4 x SPCO
Contact Rating (AC) 5A at 110V/250V AC (non-inductive)
Contact Rating (DC) 5A at 32V DC (non-inductive)
Field Terminals 2.5 mm (14 AWG)
Dimensions 132mm H x 25mm W x 119mm D
Weight 230 g
Shipping Weight 1.5 Kg

Installation Guidelines

  • Ensure the card is installed in a clean, dry environment within the control cabinet to prevent relay contact oxidation.
  • Verify that the total load connected to the relay contacts does not exceed the specified non-inductive ratings to prevent arcing.
  • Configure the Latching/Non-Latching and Energized/De-energized jumpers or switches according to your system's specific fail-safe requirements before applying power.
  • Use 2.5 mm (14 AWG) wiring for field terminals to ensure mechanical stability and correct current-carrying capacity.
  • Maintain proper separation between low-voltage signal wiring and high-voltage AC lines to prevent crosstalk and EMI.

What is the primary function of the 05704-A-0121?

This module acts as an interface card to provide connections between four sensors and a central control card.

Can the relay operation be customized?

Yes, the relay operation is selectable between Latching/Non-Latching and Energized/De-energized states.

What is the relay contact rating?

The relays are rated for 5A at 110V/250V AC or 5A at 32V DC (non-inductive).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...