1 of 1

Honeywell TC-RPCXX1 Experion Redundant Power Supply Module

Honeywell TC-RPCXX1 Experion Redundant Power Supply Module

Only 6 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TC-RPCXX1

  • Country of origin:United States

  • Product Type: Redundant Power Supply Modules

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Dimensions: 280 x 180 x 120 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Providing continuous system-level power diagnostics and hot-swappable fault tolerance, the Honeywell TC-RPCXX1 serves as a high-reliability redundant power supply module engineered for industrial control environments. This robust hardware solution integrates seamlessly into Honeywell control system architectures to deliver clean, regulated power directly to critical controllers and input/output backplanes. Designed with active load-sharing and dual-diode auctioning circuitry, the TC-RPCXX1 ensures that a single supply failure does not disrupt process operations, making it essential for high-availability process automation networks.

Features

  • Active Redundant Load Sharing: Seamlessly balances the current load with a secondary online power supply module.
  • Hot-Swappable Architecture: Allows live replacement of faulty units without de-energizing the controller backplane or interrupting operations.
  • Wide AC Input Range: Accepts international nominal utility voltages ranging from 85 to 265 VAC.
  • Comprehensive Circuit Protection: Features integrated overvoltage, overcurrent, and thermal shutdown mechanisms.
  • Status Indicator LEDs: Front-panel diagnostics provide immediate visual feedback on internal health and input/output status.

Applications

  • Honeywell Experion LX and industrial control rack systems.
  • Critical process infrastructure including petrochemical, oil and gas, and pharmaceutical plants.
  • Continuous monitoring systems requiring 24/7/365 operational uptime.

Technical Specifications

Manufacturer Honeywell
Model / Article Number TC-RPCXX1
Product Type Redundant Power Supply Module
Input Voltage Range 85 - 265 VAC
Frequency Range 47 - 63 Hz
Maximum Inrush Current 20 A
Input Power Rating 110 VA (Estimated)
Cooling Method Natural convection
Shipping Weight (Calculated) 3.0 kg (6.6 lbs)
Package Dimensions (Calculated) 280 x 180 x 120 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The TC-RPCXX1 module is directly compatible with redundant power carrier bases designed for Honeywell control systems. When replacing legacy non-redundant installations, ensure that the active backplane supports dual diode-Ored supply configurations. Always verify firmware-level diagnostics match current controller revisions, as older systems may display spurious warning alarms during live hotswap cycles if the carrier board configuration mismatch is present.

Application Pitfalls & Engineering Notes

A common issue encountered in field environments is the failure of natural convection when these power modules are crowded into high-density panels. Although rated for standard industrial temperatures, maintaining vertical clearance is critical. Avoid placing heat-generating components directly beneath the TC-RPCXX1 chassis. Operating the unit continuously at high ambient levels without active air circulation can reduce the lifespan of internal high-temperature electrolytic filtering capacitors.

Commissioning & Wiring Tips

For absolute high-availability redundancy, route the incoming AC power lines from two separate, independent UPS sources (e.g., Line A and Line B). Ensure that the frame ground (FG) lug is bonded directly to a low-impedance master ground bus. Running parallel AC lines in separate conduits is highly recommended to eliminate the risk of single-point cable failures disrupting both power input lines simultaneously.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE

Do not attempt physical installation, wiring modification, or live replacement of the redundant power system without verifying that all feeder breakers are locked and tagged out (LOTO). Internal components retain high capacitive charge even after primary AC isolation. Wait at least five (5) minutes after disconnecting power before handling internal terminal assemblies.

1
Align the TC-RPCXX1 module rails with the corresponding guides on the redundant base carrier plate.
2
Firmly slide the module back until the heavy-duty power connectors are fully seated into the backplane. Secure the mounting screws to the specified torque rating.
3
Connect separate AC power feeds to Input 1 and Input 2 terminal blocks, ensuring ground wire continuity is established first.
4
Energize the sources and verify that the module diagnostic LED indicators turn solid green, signaling healthy voltage outputs.

Can the TC-RPCXX1 module be hot-swapped while the process is active?

Yes, this module is fully hot-swappable when installed in a dual-power carrier configuration. The remaining online module automatically assumes the full load without interrupting system power.

What happens if there is an AC supply phase mismatch between redundant feeds?

The module's built-in diode-Oring isolation protects internal electronics from differences in line phase, allowing you to feed the primary and secondary units from completely separate, phase-segregated AC sources.

What cooling precautions should be taken inside a closed cabinet?

The module utilizes natural convection cooling. Maintain a minimum of 50 mm vertical clearance above and below the carrier unit, and ensure ambient cabinet temperature does not exceed standard industrial limits.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...