The NX-ECC202 is an EtherCAT Coupler Unit from the NX-series, designed to act as the primary interface between an EtherCAT network master and the distributed NX-series I/O modules. This unit facilitates high-speed, deterministic data exchange, supporting up to 63 connectable NX Units on a single slave node. Utilizing the 100BASE-TX (IEEE 802.3) physical layer with a 100 Mbps baud rate, the NX-ECC202 ensures seamless synchronization and communication within complex machine control architectures. The device is intended for panel mounting and requires integration into an EtherCAT network managed by a compatible master controller.

Features

  • Protocol: EtherCAT (100 Mbps baseband modulation)
  • Capacity: Supports up to 63 NX-series I/O modules
  • Physical Layer: 100BASE-TX (IEEE 802.3)
  • Mounting: Panel-mounted enclosure
  • Grounding: Requires a ground resistance of 100 Ohm or less

Applications

  • Distributed I/O systems in industrial automation
  • High-speed synchronized machine control
  • Modular PLC architectures
  • Factory automation network integration

Technical Specifications

Parameter Specification
Manufacturer Omron
Model NX-ECC202
Product Type EtherCAT Coupler Unit
Max Connectable Units 63
Communications Protocol EtherCAT
Baud Rate 100 Mbps
Physical Layer 100BASE-TX (IEEE 802.3)
Enclosure Panel Mounted
Grounding 100 Ohm or less
Dimensions 7.1 cm x 4.6 cm x 10 cm
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Mount the unit inside an industrial control panel. Ensure adequate spacing around the device for ventilation.
  • Grounding: To ensure signal integrity and electrical safety, connect the functional ground terminal to a common ground point with a resistance of 100 Ohm or less.
  • Network Wiring: Use shielded twisted-pair (STP) Category 5e or higher cables for 100BASE-TX EtherCAT connections to mitigate electromagnetic interference.
  • Topology: The network topology must comply with the configuration and capabilities of the designated EtherCAT master controller.

What is the maximum number of I/O modules supported by the NX-ECC202?

The NX-ECC202 can support a maximum of 63 NX-series I/O units connected to a single coupler.

What physical layer standard does this coupler use?

This unit utilizes the 100BASE-TX (IEEE 802.3) physical layer standard.

What is the required grounding resistance for this unit?

The device must be grounded to a resistance of 100 Ohm or less to maintain operational safety and noise immunity.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Japan
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...