1 of 1

Rosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8 8800D Vortex Flowmeter

Rosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8 8800D Vortex Flowmeter

Only 4 item(s) left in stock
  • Manufacturer: Rosemount

  • Product No.: 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8

  • Country of origin:United States

  • Product Type: Vortex Flowmeters

  • Payment: T/T, Western Union

  • Weight: 136000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for highly reliable steam, liquid, and gas flow measurement, the Rosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8 is an industrial inline vortex flowmeter utilizing a non-clogging sensor design to eliminate impulse lines and potential leak points. This specific configuration features a massive 12-inch (300 mm) flanged body constructed of robust CF-3M cast stainless steel and 316 wrought stainless steel wetted materials, capable of handling demanding industrial process environments.

The system is equipped with 4-20 mA digital electronics running the HART communication protocol, enabling seamless diagnostic monitoring and configuration. To ensure operator clarity on-site, a high-visibility M5 LCD display is built directly into the rugged stainless steel transmitter housing, which is configured with two M20 x 1.5 conduit entries. For safety compliance, this model comes certified with ATEX dual protection—both Flameproof (E1) and Intrinsic Safety (I1)—and includes comprehensive Q4 calibration and Q8 material traceability documentation.

Features

  • All-Welded Design: Eliminates internal gaskets, ports, and bypass lines, preventing process bypass and potential leak paths.
  • Adaptive Digital Signal Processing: Provides reliable flow signal tracking while filtering out ambient process vibration.
  • ATEX Dual Certification: Flameproof and Intrinsic Safety approvals for deployment in classified hazardous industrial zones.
  • Local Operator Interface: Includes an integrated M5 LCD indicator showing process variables and diagnostics.
  • Configurable Alarms: Dual NAMUR C4 (high alarm) and CN (low alarm) saturation and alarm values protect process equipment.
  • Quality Documentation: Ships with ISO 10474 3.1/EN 10204 3.1 calibration and material traceability certificates.

Applications

  • High-capacity steam utility lines and boiler feedwater monitoring.
  • Industrial gas distribution and compressed air management.
  • Chemical and petrochemical process fluid allocation.
  • Power plant cooling water and condensate loop measurement.

Technical Specifications

ManufacturerPart Number / ModelMeter StyleLine SizeWetted MaterialsFlange Class and ConnectionProcess Temperature RangeHousing MaterialConduit EntriesOutputsCalibration TypeHazardous Area ApprovalsDisplayAlarm ConfigurationQuality CertificatesDevice WeightShipping Weight
Rosemount (Emerson)
8800DF120SA1N7D1E1I1M5C4CN7Q4Q8
F - Standard flanged body style
12 inch (300 mm)
CF-3M Cast Stainless Steel / 316 Wrought Stainless Steel (316/316L)
ASME B16.5 RF Class 150
-40 to +450 degF (-40 to +232 degC)
Stainless steel housing
Two M20 x 1.5 conduit entries
4-20 mA digital electronics (HART Protocol)
Flow calibration
ATEX Flameproof (E1) & ATEX Intrinsic Safety ia/ic (I1)
M5 LCD indicator
C4 NAMUR high alarm, CN NAMUR low alarm and saturation values
ISO 10474 3.1/EN 10204 3.1 Calibration (Q4) & Material Traceability (Q8)
298 lb (135 kg)
136 kg

Connections and Interfaces

Terminal / Port Functional Assignment
PWR/COMM + Positive loop power supply input and HART digital communications
PWR/COMM - Negative loop power supply input and common return
TEST + / - Loop current verification terminal (allows measurement without breaking loop)
Internal Ground Electronic housing safety ground termination point
External Ground External chassis equipotential grounding lug

Installation Guidelines

  • Straight Pipe Runs: To ensure accurate flow measurement, install the meter with a minimum of 10 nominal pipe diameters upstream and 5 nominal pipe diameters downstream of straight pipe, free from valves or fittings.
  • Orientation: Can be installed in horizontal, vertical, or inclined piping. Vertical mounting with upward process flow is recommended to keep the sensor completely flooded.
  • Conduit Sealing: Install appropriate certified cable glands or conduit seals in the M20 x 1.5 entries to maintain the NEMA 4X / IP66/67 environmental rating.
  • Grounding: Always ground the transmitter housing to earth using the internal or external grounding screw terminals in accordance with local hazardous area codes.

Compliance and Certifications

  • ATEX Directive compliance for hazardous area installations.
  • Flameproof certification: ATEX II 2 G Ex d IIB+H2 T6 Gb (E1 option).
  • Intrinsic Safety certification: ATEX II 1 G Ex ia IIC T4 Ga (I1 option).
  • ISO 10474 / EN 10204 Type 3.1 material and calibration verification.

What is the process line size for the Rosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8?

This model is configured for a 12-inch (300 mm) process pipe line size with standard flanged body connections.

What process connection rating does this flowmeter use?

It is rated for ASME B16.5 RF Class 150 flanged process connections (option code A1).

What wetted materials are used in construction?

The wetted components are made of 316 wrought stainless steel and CF-3M cast stainless steel.

Which hazardous area certifications are included in this flowmeter configuration?

This flowmeter comes certified with ATEX Flameproof (E1) and ATEX Intrinsic Safety ia/ic (I1) dual approvals.

What quality certificates are provided with the Q4 and Q8 options?

The Q4 option includes a Calibration Certificate per ISO 10474 3.1/EN 10204 3.1, while the Q8 option provides a Material Traceability Certificate per ISO 10474 3.1/EN 10204 3.1.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...