1 of 1

Schneider Altistart U01 ATSU01N212LT Soft Starter

Schneider Altistart U01 ATSU01N212LT Soft Starter

Only 6 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATSU01N212LT

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 15cm x 17,5cm x 5,5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ATSU01N212LT is a compact Soft Starter from the Altistart U01 range, engineered for the smooth starting and stopping of three-phase asynchronous motors. By regulating the voltage ramp, this device effectively mitigates torque transients and high inrush currents, protecting mechanical components such as belts, chains, and gearboxes. It is designed for motors with a power rating between 2.2 kW and 5.5 kW, operating within a wide voltage supply range of 200V to 480V and a rated operational current of 12 A. Its ultra-compact design is specifically optimized for space-constrained control panels in various industrial sectors.

Features

  • Voltage ramp regulation for smooth motor acceleration
  • Integrated bypass contactor to optimize thermal performance
  • Ultra-compact form factor for high-density DIN rail mounting
  • Easy-to-adjust starting time and deceleration settings
  • Simplifies motor control for three-phase asynchronous machines

Applications

  • Small conveyors and material handling systems
  • Centrifugal and axial fans
  • Pumps and fluid processing equipment
  • Packaging and labeling machinery
  • Light-duty industrial automation tasks

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altistart
Subrange U01
Model ATSU01N212LT
Rated Operational Current 12 A
Supply Voltage 200-480 V
Motor Power Rating 2.2-5.5 kW
Commodity Code 84798997
Product Phase Active
Weight 0.45 kg
Dimensions (H x W x D) 15 x 17.5 x 5.5 cm

Installation Guidelines

  • Mounting: Designed for standard DIN rail installation. Maintain a vertical orientation to ensure proper heat dissipation.
  • Ventilation: Ensure sufficient space around the unit to allow for natural convection; do not obstruct the housing vents.
  • Wiring: Verify motor and power supply connections match the required terminal designations. Use appropriate wire gauges to handle the 12 A nominal current.
  • Grounding: Secure a reliable chassis ground to the system earth to maintain electrical safety and EMC integrity.
  • Adjustment: Use the front-mounted potentiometers to fine-tune the acceleration/deceleration ramp according to the specific load requirements of the motor.

What is the rated operational current for the ATSU01N212LT?

The rated operational current is 12 A.

Does this soft starter include a bypass contactor?

Yes, it features an integrated bypass contactor to reduce internal heat dissipation during steady-state operation.

What is the power range supported by this device?

It supports motors with power ratings between 2.2 kW and 5.5 kW.

Is this unit suitable for DIN rail mounting?

Yes, the ATSU01N212LT is specifically designed for standard DIN rail installation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...