1 of 1

Schneider Electric 170ARM37030 Modicon Momentum Discrete I/O Module

Schneider Electric 170ARM37030 Modicon Momentum Discrete I/O Module

Only 5 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: 170ARM37030

  • Country of origin:France

  • Product Type: Digital Modules

  • Payment: T/T, Western Union

  • Weight: 520g

  • Dimensions: 26cm x 18cm x 9cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The 170ARM37030 is a high-density discrete I/O module within the Modicon Momentum distributed automation family. This module is engineered for versatile signal management, featuring 10 discrete inputs and 8 relay outputs designed for operation in 24 V DC control environments.

As a key component for decentralized control architectures, this module bridges the gap between field sensors/actuators and the primary controller. While categorized as a Phase-Out product (effective since 2015), the 170ARM37030 remains a vital legacy component for supporting, expanding, and maintaining existing Modicon Momentum infrastructures where reliable relay-based output switching is required.

Features

  • Series: Modicon Momentum
  • I/O Capacity: 10 discrete inputs / 8 relay outputs
  • Operating Voltage: 24 V DC
  • Versatility: Relay outputs provide high-load switching capability for various industrial actuators.
  • Compact Design: Optimized for distributed I/O bases, allowing for efficient use of panel space.

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Brand Schneider Electric
Range Modicon Momentum
Model 170ARM37030
Type of Product Digital Module
Discrete Inputs 10
Relay Outputs 8
Supply Voltage 24 V DC
Dimensions (LxWxH) 26 cm x 18 cm x 9 cm
Weight 0.52 kg
Product Phase Phase-Out
Commodity Code 85389091

Installation Guidelines

  • Mounting: Install the module onto a compatible Momentum I/O base by aligning the connectors carefully. Ensure the module is firmly locked into position to maintain robust backplane communication.
  • Wiring: Connect 24 V DC field sensors to the input channels and external loads to the relay output contacts. Ensure that relay outputs are not subjected to loads exceeding their maximum current rating.
  • Safety: Disconnect all power sources before performing any wiring changes to prevent accidental activation of outputs or damage to the module.
  • Environment: Ensure the installation area is protected from excessive vibration, moisture, and extreme temperature fluctuations to protect the internal relay life.

What is the I/O configuration of the 170ARM37030?

This module features 10 discrete inputs and 8 relay outputs.

What voltage is required for the operation of this module?

The module is designed for 24 V DC operational environments.

What is the primary advantage of relay outputs?

Relay outputs allow for the switching of higher power or isolation of load circuits from the controller, providing more flexibility than standard solid-state outputs.

Is the 170ARM37030 still in active production?

No, this module entered the 'Phase-Out' product lifecycle stage in 2015.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
France

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...