Schneider RM4LG01B Liquid Level Control Relay

Schneider RM4LG01B Liquid Level Control Relay

Only 5 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: RM4LG01B

  • Country of origin:France

  • Product Type: Liquid Level Control Relays

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 25,00cm x 12,00cm x 10,00cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The RM4LG01B is a Liquid Level Control Relay from the RM4 range, manufactured by Schneider Electric. This device is specifically engineered to monitor and control the levels of conductive liquids in tanks or reservoirs. By utilizing probe sensors to detect liquid presence, the relay provides reliable switching functionality for pump-out (emptying) or pump-in (filling) applications, ensuring efficient process management in industrial water and chemical handling systems.

Features

  • Precision liquid level monitoring for conductive liquids
  • Adjustable sensitivity to accommodate various liquid types
  • Reliable relay output for pump motor or valve control
  • Designed for standard industrial DIN rail or panel installation

Applications

  • Level control for water storage tanks
  • Industrial chemical reservoirs
  • Wastewater management systems
  • Automated filling and emptying processes

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range RM4
Model RM4LG01B
Product Type Liquid level control relay
Weight 0.50kg
Dimensions 25.00cm x 12.00cm x 10.00cm
Commodity Code 85371099
PLM Product Status Phase-Out

Installation Guidelines

  • Mounting: Ensure the relay is mounted vertically in a control cabinet protected from moisture and extreme heat.
  • Probes: Install conductive probes at the required high and low levels. Ensure the common probe is submerged at the lowest point of the tank.
  • Wiring: Connect the probes to the input terminals as per the wiring diagram. Use shielded cable for long runs to prevent interference from adjacent power lines.
  • Sensitivity: Adjust the sensitivity dial on the front of the unit based on the conductivity of the specific liquid being monitored to ensure accurate switching.

What is the primary application of the RM4LG01B?

The RM4LG01B is used to monitor and control the levels of conductive liquids, typically for filling or emptying pumps and valves.

How does the relay detect liquid levels?

It uses conductive probes inserted into the liquid; the relay switches when the liquid makes or breaks the electrical circuit between the probes.

Can the sensitivity of the RM4LG01B be adjusted?

Yes, it features an adjustable sensitivity setting to account for the conductivity of different types of liquids.

What is the status of this product?

The RM4LG01B is currently in the phase-out stage of its product lifecycle.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Beige
Country of origin
France

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...