This is a Siemens 6ES5955-3NC12 power supply unit, engineered for the SIMATIC S5 automation platform. It provides a stable and reliable 24V DC output with a current capacity of 18A, specifically designed to power CC 135U and EU 183U system configurations. The unit's robust construction ensures consistent performance and long-term durability in demanding industrial settings, making it an essential component for maintaining system uptime and process integrity.

Features

  • Provides a regulated 24V DC output at 18A.
  • Designed for integration with the Siemens SIMATIC S5 series.
  • Direct compatibility with CC 135U and EU 183U modules.
  • Engineered for high reliability in continuous industrial operation.
  • Robust mechanical construction for enhanced durability.

Applications

  • Legacy Automation System Maintenance
  • Manufacturing and Assembly Lines
  • Process Control Systems
  • Industrial Machinery Power Distribution

Technical Specifications

Specification Value
Manufacturer Siemens
Series SIMATIC S5
Sub-Series S5-135/155
Model 6ES5955-3NC12
Product Type Power Supply Unit
Output Voltage 24V DC
Output Current 18 A
Product Lifecycle Status Obsolete
Shipping Weight 2.50 kg
Commodity Code 85389091
ECCN N
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 18.8 x 18.9 x 10.5 cm

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present. All installation and maintenance activities must be performed by qualified personnel with all power sources de-energized and locked out (LOTO). Failure to comply can result in severe injury or death.
  1. 1 De-energize System: Before installation, completely disconnect and lock out all incoming power to the control cabinet or panel. Verify the absence of voltage using a properly rated test instrument.
  2. 2 Mount the Unit: Securely mount the power supply unit into the designated slot within the SIMATIC S5 rack or chassis. Ensure all mounting hardware is properly tightened to establish a solid mechanical and electrical connection to the backplane.
  3. 3 Connect Protective Earth (PE): Connect a dedicated protective earth conductor to the designated PE terminal on the unit. This connection is critical for safety and must be the first wire connected and the last disconnected.
  4. 4 Connect Input Power: Connect the main AC or DC input power lines to the corresponding input terminals. Ensure the source voltage matches the specifications on the unit's nameplate.
  5. 5 System Verification: After all connections are secure, remove locks and re-energize the system. Check for correct status indicators on the power supply and verify that the 24V DC output is stable and within specification before allowing the PLC to enter RUN mode.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...