1 of 1

Siemens JJY:023454020001 Breaking Resistor for PowerModule PM240-2

Siemens JJY:023454020001 Breaking Resistor for PowerModule PM240-2

Only 8 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: JJY:023454020001

  • Country of origin:Germany

  • Product Type: Braking Resistors

  • Barcode: 85332900

  • Payment: T/T, Western Union

  • Weight: 20500g

  • Dimensions: 76.00cm x 40.50cm x 50.00cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The JJY:023454020001 is a Fa. Heine breaking resistor specifically designed for use with the Siemens PowerModule PM240-2 FSF. This component serves to dissipate excess energy generated during the deceleration of motor loads, ensuring stable operation of the drive system. It is engineered to handle a peak braking power (P_MAX) of 77kW for a duration of 12 seconds with a 5% duty cycle (ED). The unit features a resistance value of 7.1 Ohm and a continuous power rating (P_DAUER) of 3850W.

Features

  • Compatibility: Designed specifically for Siemens PowerModule PM240-2 FSF
  • Peak Power Handling: 77kW for 12 seconds
  • Continuous Power Rating: 3850W
  • Resistance Value: 7.1 Ohm
  • Duty Cycle: 5% ED

Applications

  • Industrial drive deceleration
  • Dynamic braking in variable frequency drive (VFD) applications
  • Heavy-duty machinery and conveyor systems
  • Load dissipation in regenerative energy management

Technical Specifications

Feature Specification
Manufacturer Siemens
Model JJY:023454020001
Resistance 7.1 Ohm
Peak Power (P_MAX) 77kW (12s / 5% ED)
Continuous Power (P_DAUER) 3850W
Dimensions 76.00 x 40.50 x 50.00 cm
Weight 20.50kg
Commodity Code 85332900
Product Phase Active

Installation Guidelines

  • Ensure adequate ventilation and clearance around the unit to allow for heat dissipation during operation.
  • Mount the resistor in a vertical or horizontal position as permitted by the enclosure design to optimize cooling.
  • Use appropriately rated cables for high-temperature applications.
  • Maintain a minimum distance from heat-sensitive components to avoid thermal damage.
  • Verify that the electrical connections are tight and that the resistance value matches the requirements of the connected PowerModule.

What is the peak power rating of the JJY:023454020001?

The peak power rating is 77kW for a duration of 12 seconds at a 5% duty cycle.

Can this resistor be used with other drive series?

This unit is specifically designed for the Siemens PowerModule PM240-2 FSF series. Use with other modules is not recommended unless specified by official Siemens documentation.

What is the resistance value of this model?

The nominal resistance value for this breaking resistor is 7.1 Ohm.

How should this resistor be installed to ensure proper cooling?

The unit must be installed in an area with sufficient airflow. Ensure clearance around the device to prevent heat buildup, as it is designed to dissipate significant thermal energy.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...