1 of 3

VIBRO-METER IPC 704 244-704-000-042 Charge-to-Current Signal Conditioner

VIBRO-METER IPC 704 244-704-000-042 Charge-to-Current Signal Conditioner

Only 7 item(s) left in stock
  • Manufacturer: VIBRO-METER

  • Product No.: IPC704 244-704-000-042

  • Country of origin:United States

  • Product Type: Signal Conditioner

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 3.2cm x 10.6cm x 13cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The IPC 704 (244-704-000-042) is a high-precision signal conditioner specifically designed to interface with CA xxx piezoelectric accelerometers and CP xxx dynamic pressure sensors. As a core component of the Vibro-Meter product line, it converts high-impedance charge-based signals into stable current or voltage outputs. This conversion is vital for TSI (Turbine Supervisory Instrumentation) and condition monitoring, as it allows for reliable signal transmission over distances up to 1 km using standard cabling, effectively shielding critical data from the electromagnetic interference common in power plant and industrial environments.

Technical Configuration (Deep Dive)

The 244-704-000-042 configuration represents a versatile hardware build intended for extreme industrial reliability.

  • Charge Amplification: The unit functions as a high-gain charge amplifier that accepts signals in picocoulombs (pC) and provides a low-impedance output.

  • Filtering Architecture: It features configurable high-pass and low-pass filters to narrow the frequency band to the specific mechanical signatures of interest, such as blade pass frequencies or bearing wear.

  • Optional Integration: This model can be configured with an internal integrator, allowing it to convert acceleration data into velocity units (mm/s or in/s) directly before transmission.

  • Signal Transmission: It utilizes a current modulation technique, which is inherently more resistant to voltage drops and electrical noise than traditional voltage-based systems.

  • RFI/EMI Protection: The moulded aluminium enclosure acts as a Faraday cage, while internal RFI filters protect the I/O stages against radio-frequency interference.

Technical Specifications

Parameter Specification Details
Model IPC 704 (244-704-000-042)
Brand Vibro-Meter (Meggitt)
Origin Switzerland
Input Compatibility CA xxx (Accelerometers), CP xxx (Pressure)
Frequency Range 0.5 Hz to 20 kHz
Output Type 2-wire current or 3-wire voltage
Operating Temp -35 to 85 deg C
Enclosure Material Moulded Aluminium
Hazardous Area Cert ATEX, IECEx, NEPSI, cCSAus

Technical FAQs

How does the current modulation benefit long-distance monitoring?

By using current modulation, the IPC 704 ensures that signal accuracy is not degraded by the resistance of long cables. This allows the conditioner to be placed in a junction box near the machine while the processing electronics (like a VM600 rack) are located up to 1,000 meters away in a control room.

Is a galvanic separation unit required for this conditioner?

Yes, when using the current transmission configuration, a GSI galvanic separation unit is required to provide the necessary power and isolation to the loop, ensuring protection against ground loops.

What is the function of the "Sensor OK" check in the IPC 704?

The conditioner monitors the bias voltage of the connected transducer. If the sensor or the input cable is shorted or open-circuited, the IPC 704 will drive its output to a predefined error level, allowing the monitoring system to trigger a "Sensor Fault" alarm instead of a false vibration trip.


Engineering & Installation Guide

  • Input Cable Requirements: Because piezoelectric sensors produce high-impedance signals, the cable between the sensor and the IPC 704 must be a specialized low-noise coaxial or mineral-insulated (MI) cable. Standard industrial wiring in this segment will cause significant signal noise due to the triboelectric effect.

  • Filter Configuration: Before commissioning, verify the jumper or solder-link settings for the high-pass and low-pass filters. For typical gas turbine vibration, a high-pass setting of 10 Hz is often used to eliminate low-frequency thermal "washout."

  • Enclosure Grounding: The aluminium housing must be securely bonded to the local instrument ground. If mounting on a DIN rail, ensure the rail itself has a low-resistance path to the earth to maximize the effectiveness of the internal RFI filters.

Engineering Advantages

The IPC 704 244-704-000-042 is distinguished by its High Dynamic Range. It is capable of processing minute pressure pulsations in combustion chambers and violent structural vibrations simultaneously without saturating the amplifier. Its Swiss-engineered circuitry provides a "Cold Start" capability, reaching stabilized measurement accuracy within seconds of power-up, which is critical for monitoring assets that undergo rapid start-up cycles.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

VIBRO-METER IPC 704 244-704-000-042 Charge-to-Current Signal Conditioner

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...