The Yokogawa AAT141-S00 is a 16-channel isolated thermocouple and millivolt input module designed for FIO systems within CENTUM VP field control stations. It functions as a signal converter by inputting field temperature and voltage signals into internal data for the Field Control Station (FCS). The AAT141-S00 module receives signals from thermocouple types J, K, E, B, R, S, T, and N, as well as mV voltage spans ranging from -100 to 150 mV and -20 to 80 mV. It supports dual-redundant configuration and connects externally via a pressure clamp terminal block.

Features

  • 16 isolated input channels for thermocouple and mV signals.
  • Software-selectable TC/mV input types individually configured for CH1 to CH16.
  • Dual-redundant configuration capability.
  • Dedicated pressure clamp terminal external connection interface.
  • Software-configurable burnout detection (UP/DOWN/Not available) for all channels.

Applications

  • Process temperature monitoring using thermocouples.
  • Millivolt analog input signal interfacing in CENTUM VP FIO DCS environments.
  • High-reliability industrial control systems requiring isolated I/O modules.

Ordering Information

Model Suffix Codes Option Codes Description
AAT141     TC/mV Input Module (16-channel, Isolated)
Suffix -S   Standard type
  0   With no explosion protection
  0   Basic type

Technical Specifications

Category Item Specification
Basic Specifications Manufacturer Yokogawa
  Model AAT141-S00
  Number of Input Channels 16, isolated
Input Specifications Input Signal

TC: JIS C1602:1995, IEC584:1995 Type J, K, E, B, R, S, T, N


 

mV: -100 to 150 mV, -20 to 80 mV

  Switching Input Signals TC/mV can be set individually for CH1 to CH16
  Allowable Input Voltage +/-5 V
  Input Resistance (Power ON/OFF) 2 MOhm or larger
Performance Accuracy

+/-30 uV (TC)


 

+/-80 uV for span (-100 to 150 mV)


 

+/-30 uV for span (-20 to 80 mV)

  Reference Junction Compensation Accuracy Within +/-1 degC (varies depending on installation and ambient temperature)
  Allowable Total Resistance 1000 Ohm or less (signal source plus wiring)
  Effect of Signal Source Resistance +/-20 uV per 1000 Ohm (+/-40 uV in dual-redundant configuration)
  Temperature Drift

+/-80 uV/10 degC (-100 to 150 mV input)


 

+/-30 uV/10 degC (TC/-20 to 80 mV input)

  Data Update Period 1 s
  Burn-out Detection All channels can be set together (Not available/available UP/DOWN), Detection time: 60 s
Electrical & Insulation Withstanding Voltage Between input and system: 1500 V AC, for 1 minute
  Maximum Current Consumption 450 mA (5 V DC)
Physical Specifications Weight 0.2 kg
  External Connection Pressure clamp terminal

Installation Guidelines

  • Use a non-ground type thermocouple (TC) because the device is an isolated type module; using ground type TC on multiple channels causes temperature errors due to multi-point ground.
  • Ensure proper installation onto supported ESB, Optical ESB, or ER bus node units.
  • Maintain matching wiring resistance for signal cables to ensure measurement accuracy.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

What input signal types are supported by the module?

The module supports thermocouple types J, K, E, B, R, S, T, and N, as well as mV voltage inputs ranging from -100 to 150 mV and -20 to 80 mV.

Why must non-ground type thermocouples be used with this module?

Because the module is an isolated type, using a ground type thermocouple across multiple channels causes temperature measurement errors due to multi-point grounding.

What is the maximum current consumption for the device?

The maximum current consumption is 450 mA at 5 V DC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

OpenVMS Alpha жүйесінде жұмыс істейтін Bailey INFI 90 Symphony HMI интерфейстерін жаңғырту

OpenVMS Alpha жүйесінде жұмыс істейтін ескірген Bailey Symphony оператор станцияларын ауыстыруға арналған практикалық нұсқаулық. Мұнда Alpha эмуляциясы, OpenVMS x86 жүйесіне көшу, OPC платформасына...

Өнеркәсіптік сенімділік үшін техникалық қызмет көрсету деректері неге маңызды?

Техникалық қызмет көрсету деректері жұмыс тапсырыстарын, сенсор сигналдарын, активтер тарихын, шығындарды және техниктердің білімін байланыстырады. Оларды дұрыс пайдалану жоспарлауды, сенімділікті,...

Гидравликалық және пневматикалық жүйелерді алмастыруға арналған электр жетектері: өнеркәсіптік автоматтандыру бойынша практикалық нұсқаулық

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты интеграцияланған электр жетектерінің дәстүрлі пневматикалық және гидравликалық жүйелерді алмастыру арқылы өнеркәсіптік қозғалысты басқару...

Өнеркәсіптік автоматтандыру қолданбаларында OpenPLC арқылы математикалық операцияларды орындау

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыру аясында қосу, азайту, көбейту, бөлу, қалдықты есептеу және дәрежеге шығару сияқты негізгі математикалық амалдарды қалай орындайтыны...

FBD PLC бағдарламалауындағы жетілдірілген булевтік логика: негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауда негізгі AND, OR және NOT операцияларынан бөлек қолданылатын бірнеше жетілдірілген логикалық функция түсіндіріледі. Онда күрделірек басқару сценарийлерін өңдеу және...

PLC бағдарламалауындағы бульдік логика: FBD логикалық қақпаларын түсіну

Логикалық алгебра — әрбір PLC бағдарламасының негізі. Қарапайым машина басқару жүйелерінен бастап күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін логикалық қақпалар контроллерлердің өзгеретін...