Description

The Allen-Bradley 1756-LSP serves as a dedicated, hardware-isolated redundant co-processor within safety-instrumented systems to execute multi-channel diagnostic and lockstep safety verification logic. Operating as a specialized safety partner module paired with a primary controller, this unit establishes an isolated secondary execution environment to safely handle safety-related functions up to and including SIL 3 and Performance Level e requirements. The device contains no localized user memory for standard operations; instead, its configuration parameters, clock operations, and safety memory structures are bound to and managed by the corresponding master unit.

Features

  • 1-Slot Co-Processing Footprint: Occupies a single slot immediately adjacent to the primary controller, forming a two-slot processing pair within the chassis backplane.
  • Dynamic Safety Memory Allocation: Safety allocation corresponds directly to the paired master unit, providing 1 MB when paired with 1756-L61S or 1756-L62S, and 3.75 MB when linked with a 1756-L63S.
  • High Connection Density: Manages up to 250 data connections for handling complex industrial safety interlock distributions.
  • Integrated Diagnostics: Built-in LED status indicators provide immediate local visual confirmation of execution states, errors, and sync conditions.
  • Nonvolatile Flash Backup: Ships complete with a pre-installed CompactFlash card to ensure secure storage of firmware images and operating parameters.

Applications

  • SIL 3 and Performance Level e (PL e) emergency shutdown loops in high-risk industrial fields.
  • Lockstep co-processing pairs within automated burner management systems (BMS) and pressing cells.
  • Fail-safe interlock handling in manufacturing setups requiring strict isolation from standard control logic execution paths.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Model Part Number 1756-LSP
Module Type Safety Partner Module
Series GuardLogix 5560
Compatible Primary Controllers 1756-L61S, 1756-L62S, 1756-L63S
Supported Connections 250
User / Standard Memory N/A (None)
Current Draw @ 5.1V DC 1200 mA
Current Draw @ 24V DC 14 mA
Power Dissipation 3.5 W
Thermal Dissipation 11.9 BTU/hr
Isolation Voltage 30V Continuous (Basic Insulation, Type-tested from RS-232 port-to-system at 720V DC for 60 seconds)
Local Serial Interface 1 x RS-232 port
Backup Battery Element 1756-BA2 (0.50 g lithium assembly)
Chassis Slot Width Allocation 1 slot (Requires adjacent slot for primary module; 2 slots total for operation)
Chassis Compatibility 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17
Power Supply Compatibility 1756-PA50, 1756-PA72, 1756-PA75, 1756-PB50, 1756-PB72, 1756-PB75
Enclosure Class None (Open-Style)
Operating Temperature Range 0 Celsius to 60 Celsius
Non-Operating Temperature -40 Celsius to 85 Celsius
Relative Environmental Humidity 5-95% non-condensing
Mechanical Shock (Operating) 30 g
Mechanical Shock (Non-Operating) 50 g
Vibration Stress Tolerance 2 g at 10-500 Hz
Shipping Weight (Calculated) 0.75 lbs (0.34 kg)
Physical Dimensions (Calculated) 27 x 17 x 7 cm (10.63 x 6.69 x 2.76 in.)

Alternative Models & Compatibility

The 1756-LSP safety partner is structurally locked to the GuardLogix 5560 architecture. It functions solely when paired alongside a 1756-L61S, 1756-L62S, or 1756-L63S safety controller. Attempting to link this safety module with standard ControlLogix non-safety processors or newer ControlLogix 5570/5580 systems will result in backplane verification errors and halt CPU configuration loading.

Application Pitfalls & Engineering Notes

A major engineering pitfall occurs when calculating available workspace inside open enclosures. If the safety partner is not placed in the slot directly to the right of its primary controller, the pair cannot satisfy structural SIL 3 requirements, causing a total breakdown of safety loop integrity. Furthermore, because this card relies completely on the master controller for communication links and configuration parameters, its onboard RS-232 port cannot be independently utilized for broad network mapping or logic modification. Ensure the onboard 1756-BA2 lithium battery cell is monitored regularly; low energy levels can corrupt clock operations during complete system power blackouts.

Installation Guidelines

CRITICAL WARNING: De-energize and lock out all main backplane paths and external auxiliary supply voltages before mounting or extracting the co-processor hardware. Handling module installation steps while the rack contains active residual voltage risks triggering unexpected backplane noise spikes, communication drops on adjacent nodes, or component degradation.
1
Verify the position of the primary master controller (1756-L61S, -L62S, or -L63S) within the selected standard 1756 chassis rack.
2
Clear the unmanaged slot situated immediately to the right of that primary unit to allow proper mechanical alignment for SIL 3 tracking.
3
Align the circuit card tracks of the safety partner module with the plastic guides of the intended empty slot.
4
Slide the unit smoothly backward into the slot until the upper and lower mechanical clips seat flush and snap lock onto the chassis rim.
5
Restore power to the chassis and examine the forward LED cluster to confirm initialization and paired connection handshakes with the primary processor.

Does this safety partner module possess independent memory for user application logic?

No. The module contains no independent user memory for standard operations. It functions strictly as a redundant co-processor whose safety memory allocation depends on the memory footprint of the paired primary unit.

Can this module be placed in any open slot inside a ControlLogix chassis?

To satisfy SIL 3 safety compliance, the module must be mounted in the slot located immediately to the right of the primary safety controller.

What is the memory size allocation when pairing this unit with a 1756-L63S master processor?

When integrated with a 1756-L63S primary controller, the safety partner matches it by providing a safety memory structure of 3.75 MB.

What replacement battery type is required for this co-processor unit?

The module requires a 1756-BA2 lithium battery assembly, which contains approximately 0.50 grams of lithium to maintain clock and internal backup parameters.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Czarny
Country of origin
Stany Zjednoczone
Power source
Zasilanie prądem stałym Zasilany baterią

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...