The 125712-01 is a full-height spare component designed to provide four independent relay outputs within the 3500 Series Machinery Protection System. This module functions by executing highly customizable voting logic directly driven by machine alerts and danger levels across the system enclosure. Each output terminal incorporates specialized Alarm Drive Logic, which can be custom configured with complex AND or OR Boolean expressions using the 3500 Rack Configuration Software to manage specific automated trip signals. It operates reliably when located to the right of the main Rack Interface Module, delivering discrete contact outputs for field control links, emergency stop systems, or external industrial annunciators.

Features

  • Four fully programmable, independent relay outputs supporting complex localized system voting logic.
  • Configurable Alarm Drive Logic utilizing combinational AND/OR gate selections for flexible machine-state actions.
  • Multi-channel compatibility accepting alert and danger alarm inputs from any active monitor card in the local rack.
  • Front-panel visual diagnostics including dedicated LEDs for Module OK, active TX/RX communications, and individual relay state indicators.
  • High-integrity epoxy-sealed relay hardware utilizing pairs of single-pole double-throw (SPDT) relays in a unified double-pole double-throw (DPDT) physical arrangement.
  • Hardware switch-selectable functionality for setting channels to either Normally Energized (NE) or Normally De-energized (NDE) operation.

Applications

  • Mechanical trip systems and emergency shutdown integration.
  • Automated industrial voting logic and alarming systems for large rotating assets.
  • Critical turbomachinery and industrial compressor protective interlocking networks.

Ordering Information

Part Number / Option Description
3500/32-A01-B00 4-Channel Relay Module with I/O Module, No Agency Approvals 
3500/32-A01-B01 4-Channel Relay Module with I/O Module, CSA/NRTL/C Approval 
125712-01 Spare 4-Channel Relay Module (Main Board) 
125720-01 Spare 4-Channel Relay I/O Module 
00580436 Connector Header, Internal Termination, 6-position, Green 

Technical Specifications

Category Specification Data
Electrical Power Consumption 6 watts typical 
  Relay Type Two SPDT relays connected in a DPDT configuration 
  Environmental Sealing Epoxy-sealed 
  Arc Suppressor 250 Vrms, installed as standard 
Contact Ratings Max Switched Current 5 A 
  Max Switched Voltage (dc) 30 Vdc 
  Max Switched Voltage (ac) 250 Vac 
  Max Switched Power (dc) 120 W 
  Max Switched Power (ac) 600 VA 
  Minimum Switched Current 10 mA @ 5 Vdc 
  Contact Life 100,000 cycles @ 5 A, 24 Vdc or 120 Vac 
Environmental Operating Temperature -30 degC to +65 degC (-22 °F to +150 °F) 
  Storage Temperature -40 degC to +85 degC (-40 °F to +185 °F) 
  Humidity 95%, non-condensing 
Mechanical Main Module Dimensions (H x W x D) 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in) 
  Main Module Weight 0.7 kg (1.6 lb.) 
  Rack Space (Main Module) 1 full-height front slot 
  Rack Space (I/O Module) 1 full-height rear slot 
  Manufacturer Bently Nevada 

Connections/Interfaces

Terminal Designation Function
NC Normally Closed contact connection terminal for external equipment loops 
ARM Armature (Common) contact interface terminal for external field wiring 
NO Normally Open contact connection terminal for external equipment loops 
RELAY MODE (Switch) Hardware selector switches for Normally De-energized (NDE) or Normally Energized (NE) mode 

Installation Guidelines

  • Slot Allocation: Position the module in any available full-height slot directly to the right of the 3500 Rack Interface Module.
  • Relay Mode Configuration: Before commissioning, configure individual channel hardware switches located on the module to specify either Normally De-energized (NDE) or Normally Energized (NE) operation based on the field device type.
  • Software Configuration: Use the 3500 Rack Configuration Software to map specific combinations of alert or danger alarms across monitor channels into the module's localized Alarm Drive Logic.

Compliance and Certifications

  • EMC Emissions: EN 55011 Class A (Radiated and Conducted Emissions).
  • EMC Immunity: IEC61000-6-2, EN 61000-4-2 (Electrostatic Discharge Criteria B), ENV 50140 (Radiated Susceptibility Criteria A), ENV 50141 (Conducted Susceptibility Criteria A), EN 61000-4-4 (Electrical Fast Transient Criteria B), EN 61000-4-5 (Surge Capability Criteria B), 61000-4-8 (Magnetic Field Criteria A), EN 61000-4-11 (Voltage Dip Criteria B), ENV 50204 (Radio Telephone Criteria B).
  • Safety Requirements: EN 61010-1 Low Voltage Directives.
  • Hazardous Area Approvals: CSA/NRTL/C; Class I, Div 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 condition. Certification Number: CSA 150268-1002151 (LR 26744).

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 125712-01 4-Channel Relay Module

Can this relay module be used in Triple Modular Redundant configurations?

No. Triple Modular Redundant (TMR) applications require the use of the 3500/34 TMR Relay Module instead of this standard 4-channel version.

What are the contact ratings for resistive loads on these relays?

The maximum ratings are 5 A with a maximum switched voltage of 30 Vdc or 250 Vac. The maximum switched power is 120 W for DC or 600 VA for AC.

How do you program the voting and driving logic for each channel?

The voting logic is configured by setting up AND and OR gates using the 3500 Rack Configuration Software, which pulls alert and danger states from monitor channels.

What do the front-panel TX/RX LEDs indicate?

The TX/RX LED flashes to indicate active and proper communications between this relay module and other modules within the 3500 rack framework.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Srebro
Country of origin
Stany Zjednoczone

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...