1 z 1

Bently Nevada 330878-90-CN 3300 XL 50 mm Proximitor Sensor

Bently Nevada 330878-90-CN 3300 XL 50 mm Proximitor Sensor

Only 7 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 330878-90-CN

  • Country of origin:Stany Zjednoczone

  • Product Type: Proximitor Sensors

  • Payment: T/T, Western Union

  • Weight: 320g

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

Conditioning dynamic eddy current signals for high-reliability machinery diagnostics, the Bently Nevada 330878-90-CN operates as a key component of the 3300 XL 50 mm Proximitor Sensor system. This unit converts the radio frequency (RF) signal generated by the proximity probe into a proportional voltage output, enabling precise measurements of shaft displacement, vibration, and position in heavy rotating machinery. The specific -90-CN configuration designates a 9.0-meter system length with panel-mounting capability and regional-specific safety certifications.

Features

  • Optimized for the high-aperture fields of 50 mm proximity probes.
  • 9.0-meter (29.5 feet) total system length calibration matches probe and extension cable impedance.
  • Rugged panel-mount design for secure installation within industrial junction boxes or instrument enclosures.
  • Corrosion-resistant A380 cast aluminum housing provides superior durability in harsh environments.
  • CN agency approval designation for country-specific regulatory compliance.

Applications

  • Thrust and radial vibration monitoring on large utility-scale steam and gas turbines.
  • Shaft centerline tracking and displacement analysis in hydroelectric generators.
  • Mechanical protection loops for high-horsepower industrial compressors and process pumps.
  • Torsional and structural displacement monitoring in power generation and marine propulsion.

Technical Specifications Table

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Model Number 330878-90-CN
Sensor Series 3300 XL 50 mm
System Length 9.0 meters (29.5 feet)
Mounting Configuration Panel Mount
Housing Material A380 Aluminum
Operating Temperature -51 degC to +100 degC (-60 degF to +212 degF)
Storage Temperature -51 degC to +105 degC (-60 degF to +221 degF)
Agency Approvals CN (Country Specific Approvals)
Shipping Weight (Calculated) 3.0 kg (6.6 lbs)
Country of Origin United States

Connections and Interfaces

Terminal / Port Function / Circuit Assignment
Coaxial Jack Accepts RF cable connection from the 3300 XL 50 mm extension cable / probe assembly.
Terminal VT Power input supply (-24 Vdc nominal).
Terminal OUT Dynamic output voltage signal (proportional to target distance).
Terminal COM Common ground reference.

Alternative Models & Compatibility

The 330878-90-CN must only be paired with 3300 XL 50 mm proximity probes and equivalent 9.0-meter matching systems. It is not interchangeable with 8 mm or 11 mm Proximitor sensors, as the internal oscillators and linearization curves are explicitly tuned for the electromagnetic footprint of the large 50 mm probe head. Intermixing components across different millimeter-scale families will lead to severe calibration drift and false machine trip signals.

Application Pitfalls & Engineering Notes

The 50 mm sensor system generates a broad electromagnetic field. Ensure that a clear, unobstructed side-clearance zone is maintained around the probe head to prevent parasitic targets (such as machine casing walls or internal brackets) from entering the detection field. Operating outside the rated temperature envelope (-51 degC to +100 degC) will degrade the sensor's temperature compensation circuitry, introducing measurement offset errors.

Commissioning & Wiring Tips

Always check the coaxial connector insulation prior to startup. The outer connector sleeve must be kept completely isolated from the machine ground; utilize Bently Nevada connector protectors or silicone heat-shrink tubing over the coaxial junctions. For signal integrity, route field wiring inside dedicated, grounded conduit, keeping it physically separated from high-voltage motor supply runs to minimize electromagnetic interference.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all external power sources before handling terminal block wiring. Failure to de-energize active monitoring systems prior to connection can introduce electrical transients that may cause damage to the monitoring rack input cards or trigger spurious turbine emergency trips.

1

Mount the Proximitor housing securely on the subpanel using the integrated mounting flanges. Ensure the mounting plate has a solid path to the structural instrument ground.

2

Connect the 9.0-meter extension cable coaxial plug to the sensor's coaxial jack. Hand-tighten the connector and ensure the mechanical locking mechanism is secure.

3

Install three-wire shielded instrument cabling to the VT, OUT, and COM screw terminals, maintaining proper torque to prevent loose terminations.

4

Ground the cable shield exclusively at the monitor rack/safety barrier end; do not connect the shield to ground at the Proximitor sensor terminal block to avoid ground loops.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330878-90-CN 3300 XL 50 mm Proximitor Sensor

Can I use the 330878-90-CN with a standard 3300 XL 8 mm proximity probe?

No. The 330878-90-CN is designed and calibrated exclusively for the larger 3300 XL 50 mm probe system. Utilizing it with an 8 mm or 11 mm probe will cause incorrect scale factor output and inaccurate measurements.

What is the physical significance of the -90 configuration suffix?

The -90 suffix indicates a 9.0-meter (29.5 feet) calibrated system length with a panel-mount option. The internal impedance matching of the sensor requires a total physical cable length (probe plus extension) of exactly 9.0 meters.

What does the CN approval code mean on this Proximitor Sensor?

The CN option indicates country-specific agency approvals, typically signifying compliance with hazardous area standards and operational specifications required for localized plant deployment in China.

How do I ground the 330878-90-CN sensor housing?

The sensor should be panel-mounted to a metal subplate that is tied to local safety ground. However, the coaxial connection and cable shields must be kept isolated from the housing to prevent electrical ground loops that corrupt signal data.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Niebieski Srebro
Country of origin
Stany Zjednoczone

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...