Description

The 3500/32 is a full-height component designed for the Bently Nevada 3500 series machinery protection system, providing four fully programmable relay outputs. This module can be placed in any of the slots to the right of the Rack Interface Module to drive critical alarm and machinery shutdown logic. Each relay utilizes highly configurable Alarm Drive Logic, which can be custom programmed using AND and OR combinations of alerts and dangers from any monitor channel within the rack. This decentralized logic configuration operates via the 3500 Rack Configuration Software to execute protective actions instantly, independent of host software control.

The hardware employs a highly resilient relay setup consisting of two single-pole, double-throw (SPDT) relays arranged in a double-pole, double-throw (DPDT) configuration for each of its four channels. Every channel features switch-selectable operations for Normally De-energized or Normally Energized modes, enabling flexible adaptation to fail-safe industrial layouts. Built-in onboard LED indicators allow field operators to perform dynamic, at-a-glance status tracking of communication buses and individual relay alarm conditions.

Features

  • Four independent relay outputs offering fully customizable, channel-specific voting logic paths.
  • Alarm Drive Logic programming supporting extensive combinations of AND/OR parameters across rack-wide inputs.
  • Dual SPDT relays connected in a robust DPDT physical layout for each independent channel.
  • Epoxy-sealed relay constructions integrated with standard 250 Vrms arc suppressors for sustained contact safety.
  • Onboard switch-selectable control allowing direct toggling between Normally Energized and Normally De-energized states.
  • Clear front-panel LED diagnostics indicating module OK, communication (TX/RX), and individual channel alarm status.

Applications

  • Automatic emergency trip logging and machinery shutdown loops on critical industrial turbomachinery.
  • Interlocking plant safety systems and visual/audible alarm annunciator drive networks.
  • Distributed voting logic configurations for balance-of-plant protection matrices across power generation and oil refineries.

Ordering Information

Detail Product Ordering Reference
Main Model Designation 3500/32 (4-Channel Relay Module) 
Output Module Option -01 (4-Channel Relay I/O Module) 
Agency Approval Option -00 (None) 
  -01 (CSA / NRTL / C) 

Technical Specifications

Parameter Detail
Manufacturer Bently Nevada (Baker Hughes)
Model Designation 3500/32 
Product Type 4-Channel Relay Module 
Power Consumption 6 watts typical 
Relay Type Configuration Two SPDT relays connected in a DPDT configuration per channel 
Environmental Sealing Epoxy-sealed 
Arc Suppressor Rating 250 Vrms (installed as standard) 
Contact Life Performance 100,000 cycles at 5 A, 24 Vdc or 120 Vac 

 

Max Switched Voltage

dc: 30 Vdc / ac: 250 Vac 
Max Switched Current 5 A 
Minimum Switched Current 10 mA @ 5 Vdc 

 

Switched Power Capacity

dc: 120 W / ac: 600 VA 
Main Module Dimensions (H x W x D) 241 mm x 24.4 mm x 242 mm 
Main Module Weight 0.7 kg 
I/O Module Dimensions (H x W x D) 241 mm x 24.4 mm x 99.1 mm 
I/O Module Weight 0.4 kg 
Operating Temperature Bounds -30 degC to +65 degC 
Storage Temperature Bounds -40 degC to +85 degC 
Humidity Constraints 95%, non-condensing 
Rack Space Requirement (Main) 1 full-height front slot 
Rack Space Requirement (I/O) 1 full-height rear slot 

Connections/Interfaces

Terminal Connection Function Assignment
NC Normally Closed contact connection point per relay channel 
ARM Armature / Common contact connection point per relay channel 
NO Normally Open contact connection point per relay channel 
RELAY MODE (NDE/NE) Hardware slide switches controlling individual channel energization states 

Installation Guidelines

  • Module Placement: Slide the main card directly into any available full-height front slot to the right of the Rack Interface Module. Insert the corresponding I/O module into the matching rear chassis slot. Secure all faceplate screws.
  • Relay Mode Selection: Adjust the dedicated hardware switches on the I/O panel prior to module power-up to establish Normally De-energized (NDE) or Normally Energized (NE) operation based on loop design.
  • Wiring Configurations: Land all external device circuits onto the rear screw termination header block. Ensure proper landing for NC, ARM, and NO contact segments to prevent mechanical signaling errors.
  • Electrostatic Grounding: Utilize a single-use grounding wrist strap when unboxing or modifying the internal circuitry parameters to safeguard the board elements from electrostatic shock.

Compliance and Certifications

  • CE Mark Directives: Compliant with EMC Directive standards.
  • Radiated & Conducted Emissions: EN 55011, Class A.
  • Immunity & Susceptibility Standard: IEC 61000-6-2, including ESD (61000-4-2), Radiated (ENV 50140), Conducted (ENV 50141), EFT (EN 61000-4-4), Surge (EN 61000-4-5), and Magnetic Field (61000-4-8).
  • Hazardous Area Approvals: CSA/NRTL/C certified for Class I, Division 2, Groups A, B, C, D (T4 @Ta = -20 degC to +65 degC; Certification Number: CSA 150268-1002151).

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/32 4-Channel Relay Module

Can this relay module be utilized within Triple Modular Redundant configurations?

No. Triple Modular Redundant (TMR) applications require the specialized 3500/34 TMR Relay Module rather than the standard 3500/32 4-Channel Relay Module.

What configuration controls the baseline operational state of the relay contacts?

Each independent channel features physical switches on the hardware module that allow the selection between Normally De-energized and Normally Energized operations.

What built-in protection is provided to control contact degradation from electrical arcing?

Every channel on the module comes equipped with a 250 Vrms arc suppressor installed as standard equipment to mitigate damage from switching arcs.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Srebro
Country of origin
Stany Zjednoczone
Power source
Zasilanie prądem stałym

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...