1 z 1

Bently Nevada 3500/91-01-CN EGD Communication Gateway Module

Bently Nevada 3500/91-01-CN EGD Communication Gateway Module

Only 8 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/91-01-CN

  • Country of origin:Stany Zjednoczone

  • Product Type: Communication Gateway Modules

  • Payment: T/T, Western Union

  • Weight: 790g

  • Dimensions: 241.3 mm x 24.4 mm x 241.8 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

The 3500/91-01-CN is an Ethernet Global Data (EGD) communication gateway module designed for the Bently Nevada 3500 machinery protection system. This module provides comprehensive communication capabilities for transmitting 3500 rack-monitored values, statuses, data values (float), and setpoints (float) over an Ethernet network path. It interfaces directly with EGD protocol compatible controllers to deliver response times suitable for demanding industrial controller applications. The module enables integration via Ethernet UDP/IP frames , processing both producer exchanges and consumer exchanges such as group resets, group trip multiplies, group alarm inhibits, and group special alarm inhibits.

Features

  • Provides integration of 3500 rack values with EGD protocol compatible controllers.
  • High-speed data transfer via Ethernet UDP/IP protocol.
  • Supports EGD version 2.01 protocol.
  • Front panel LEDs indicate module operational health (OK LED) and rack communication status ($TX/RX$ LED).
  • Accommodates different physical layers including 10BASE-T/100BASE-TX (twisted pair) and 100BASE-FX (fiber optic) via interchangeable I/O modules.

Applications

  • Machinery protection and condition monitoring systems.
  • Distributed Control System (DCS) and Programmable Logic Controller (PLC) integration.
  • Power generation facilities, petrochemical plants, and heavy industrial processing environments requiring real-time machinery asset data.

Ordering Information

Code Description
3500/91 EGD Communication Gateway 
-AA

 

Main Module Type 

01 EGD Communication Gateway Module 
-BB

 

I/O Module Type 

01 Ethernet 10BASE-T/100BASE-TX I/O Module 
02 Ethernet 100BASE-FX I/O Module 
-CC

 

Agency Approval Option 

00 None 
01 CSA/NRTL/C 
02 CSA/A 

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (Baker Hughes) 
Product Model 3500/91-01-CN 
Product Type EGD Communication Gateway Module 
Country of Origin United States of America
Power Consumption 7.4 watts typical 
Data Types Supported Rack, Module, Channel, and Data value Status; Data values (float); Setpoints (float) 
Producer Exchanges Status, Data values, Setpoints 
Consumer Exchanges Group Reset, Group Trip Multiply, Group Alarm Inhibit, Group Special Alarm Inhibit 
Protocols EGD Version 2.01, Ethernet UDP/IP frame, IEEE 802.3 CSMA/CD 
Communication Link Ethernet 10-Mbps and 100-Mbps (conforms to IEEE 802.3 and IEEE 802.3u) 
Main Module Dimensions 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) 
Main Module Weight 0.79 kg (1.75 lbs.) 
I/O Module Dimensions 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) 
I/O Module Weight 0.39 kg (0.85 lbs.) 
Rack Space - Main Module 1 full-height front slot 
Rack Space - I/O Module 1 full-height rear slot 
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF) 
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF) 
Humidity 95%, noncondensing 

Connections/Interfaces

Interface Connector / Jack Type Function
Ethernet 10BASE-T/100BASE-TX I/O Module RJ-45 jack  Twisted pair Ethernet network communication link 
Ethernet 100BASE-FX I/O Module MT-RJ jack  Fiber optic Ethernet network communication link 

Installation Guidelines

  • Rack Allocation: Install the main module into one full-height front slot of the 3500 rack. The associated I/O module must be positioned directly behind it in the corresponding full-height rear slot.
  • System Requirements: This module requires Version 3.70 or higher of the 3500 Rack Configuration Software for setup.
  • Hardware Interfacing: The module must interface with a 3500/22M Transient Data Interface (TDI) utilizing firmware version 1.20 or higher to successfully communicate with individual monitor modules.
  • System Constraints: Only one EGD module is permitted per 3500 rack.
  • Firmware Requirements: For consumed exchange support, version 2.21 or higher of the 4-Channel firmware is mandatory.

Compliance and Certifications

  • FCC: Complies with part 15 of the FCC Rules regarding harmful interference.
  • EMC: European Community Directive 2014/30/EU; Standards EN 61000-6-2 (Immunity for Industrial Environments) and EN 61000-6-4 (Emissions for Industrial Environments).
  • Electrical Safety: European Community Directive 2014/35/EU (LV Directive) conforming to Standard EN 61010-1.
  • RoHS: European Community Directive 2011/65/EU.
  • Maritime: DNV GL rules for classification (Ships, offshore units, high speed/light craft) and ABS Rules for Condition of Classification (Part 1, Steel Vessels Rules, Offshore Units and Structures).
  • Hazardous Area Approvals: * CNRTLUS: Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC when installed per drawing 149243 or 149244.
    • ATEX/IECEx: Ex II 3 G; Ex nA nc ic IIC T4 Gc; Ex ec nc ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC when installed per drawing 149243 or 149244.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/91-01-CN EGD Communication Gateway Module

How many EGD gateway modules can be installed in a single 3500 rack?

Only one EGD communication gateway module is allowed per 3500 rack.

What software and firmware versions are required to use this module?

It requires 3500 Rack Configuration Software version 3.70 or higher, and the 3500/22M TDI must use firmware version 1.20 or higher.

What types of physical Ethernet interfaces are available for this gateway?

It supports either an RJ-45 jack for 10BASE-T/100BASE-TX twisted pair cabling or an MT-RJ jack for 100BASE-FX fiber optic connections, depending on the I/O module selected.

What is the operating temperature range for this module in hazardous areas?

The certified ambient operating temperature range for hazardous area installations is -20 degC to +65 degC.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Srebro
Country of origin
Stany Zjednoczone

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...