1 z 3

Bently Nevada 991-06-70-01-CN 991 Thrust Transmitter

Bently Nevada 991-06-70-01-CN 991 Thrust Transmitter

Only 5 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 991-06-70-01-CN

  • Country of origin:Stany Zjednoczone

  • Product Type: 991 Thrust Transmitter

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 820g

  • Dimensions: 100.1 mm x 73.9 mm x 53.3 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

The Bently Nevada 991-06-70-01-CN is a 2-wire, loop-powered 991 Thrust Transmitter engineered to measure axial shaft position and thrust displacement on rotating machinery. The transmitter processes raw signals from a compatible proximity probe system and conditions them into a stable 4 to 20 mA DC output directly proportional to mechanical movement. This design allows for direct integration into PLCs, DCS architectures, or SCADA systems without requiring a dedicated machinery protection monitor rack. It provides continuous, cost-effective monitoring for critical industrial assets where axial displacement tracking is required to prevent catastrophic thrust bearing failure.

Features

  • Loop-powered 2-wire architecture reduces field wiring overhead and installation costs.
  • Standard 4 to 20 mA DC analog output connects directly to process control systems.
  • Front-panel BNC jack provides a buffered raw voltage signal for diagnostics and portable data collectors.
  • Non-contacting eddy current sensing technology ensures long-term wear-free operation.
  • Compact, space-saving design suitable for direct high-density DIN rail mounting.

Applications

  • Centrifugal compressor axial thrust displacement monitoring
  • Steam and gas turbine rotor position tracking
  • High-pressure boiler feed pump shaft alignment
  • Industrial gearbox thrust bearing wear diagnostics
  • Forced draft and induced draft fan shaft positioning

Ordering Information

  • 991: Thrust Transmitter
  • 06: 3300 XL 8 mm proximity probe compatibility with 1.0 mm linear range
  • 70: 7.0 metres system length option
  • 01: 35 mm DIN rail mounting option
  • CN: Approvals option certified for specialized regional or country-specific standards (China/NEPSI/GB)

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Country of Origin United States
Product Type Thrust Transmitter
Output Signal 4 to 20 mA DC
Power Input 17 to 30 VDC
Linear Range 1.0 mm (approx. 40 mils)
Transmitter Operating Temperature -35 to +85 Celsius (-31 to +185 deg F)
Transmitter Storage Temperature -51 to +100 Celsius (-60 to +212 deg F)
Probe Operating Temperature -52 to +177 Celsius (-62 to +351 deg F)
Enclosure Material Zinc-plated steel or structural polymer
Mounting Base 35 mm DIN rail mount (or bulkhead mount configuration)
Transmitter Weight 0.43 kg (0.9 lbm)
Total System Weight 0.82 kg (1.8 lbm) typical
Footprint / Base Dimensions 100.1 mm x 73.9 mm (3.94 in x 2.91 in)
Mounting Hole Pattern (Bulkhead) 69.9 mm x 63.5 mm (2.75 in x 2.50 in)
Height (Including DIN Clip) 53.3 mm (2.10 in)
Height (Body Only) 42.6 mm (1.68 in)
Mounting Hole Diameter 5.8 mm (0.23 in), 4 places

Connections / Interfaces

Connector Pin Function
+4-20mA / +VTX Positive Power Supply / Current Loop Input
-4-20mA / -VTX Negative Power Supply / Current Loop Return
PROX Proximity Probe Center Conductor Input
COM Common Reference / Coaxial Shield Terminal
SHLD Instrument Shield Ground Terminal
BNC Jack Dynamic Voltage Signal Output (10.2 mV/micrometer)

Installation Guidelines

  • DIN Rail Attachment: Secure the housing firmly onto a standard 35 mm DIN rail using the integrated DIN mount clips inside a protective industrial enclosure rated IP54 or higher.
  • Bulkhead Mounting Option: Alternatively, use the 4 mounting holes ($5.8 \text{ mm}$ diameter) spaced at $69.9 \text{ mm} \times 63.5 \text{ mm}$ for flat panel/bulkhead installations with the provided 6-32 x 1.326 screws.
  • Shielding Protocol: Connect the input transducer cable shield to the SHLD terminal. The external control loop shield must be grounded at the control system (PLC/DCS) side only to eliminate ground loops.
  • Probe Gapping: Set the physical probe gap using a digital voltmeter across the BNC jack or COM terminals to verify the sensor sits within its linear voltage range before operation.
  • Separation of Wiring: Route all input sensor cables and output current loop wiring away from high-voltage AC lines or variable frequency drive cables to mitigate EMI/RFI noise.

Compliance and Certifications

  • CN Approval Variant (Certified for regional hazardous area compliance, such as NEPSI / GB standards)

FAQ

What are the exact enclosure dimensions for cabinet layout planning?

The base footprint measures 100.1 mm in length by 73.9 mm in width, with a maximum profile height of 53.3 mm when the 35 mm DIN rail clip is attached.

What size are the alternative bulkhead installation holes?

The unit features 4 mounting holes with a diameter of 5.8 mm, laid out in a precise 69.9 mm by 63.5 mm rectangular center pattern.

What is the function of the BNC connector on the faceplate?

It provides an unconditioned, buffered raw voltage output for connecting diagnostic instruments and dynamic signal analyzers without disrupting the 4 to 20 mA current loop.

Does this device require a separate power supply line?

No, it operates entirely on loop power, drawing its operating voltage directly from the 4 to 20 mA signal line.

What happens if the system length option is mismatched with the probe?

Connecting a probe/extension cable combination that does not match the specified 7.0-metre calibration will result in severe measurement non-linearity and scale factor errors.

Can this transmitter be mounted in an outdoor environment?

It must be installed within a weatherproof NEMA 4X or IP65/66 rated field junction box to protect it from moisture, dust, and direct sunlight.

Is the transmitter output compatible with standard analog input cards?

Yes, the 4 to 20 mA output directly connects to standard differential or single-ended analog input cards on any PLC or DCS.

What is the meaning of the CN suffix code?

The CN suffix denotes specific regional certification compliance, commonly matching China national safety and hazardous area standards.

Can the unit be calibrated in the field for different linear ranges?

No, the linear range and scale factors are hard-wired and factory-calibrated. Range changes require a different model configuration.

How does reverse loop polarity affect the transmitter?

The device features internal diode protection against reverse polarity, meaning it will not function when wired backward but will not be damaged.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 991-06-70-01-CN 991 Thrust Transmitter

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Szaro-biały
Country of origin
Stany Zjednoczone

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...