1 z 1

Honeywell MC-TAMT04 Thermocouple Input Terminal Board

Honeywell MC-TAMT04 Thermocouple Input Terminal Board

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: MC-TAMT04

  • Country of origin:Stany Zjednoczone

  • Product Type: Thermocouple Input Terminal Boards

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 31.0 cm x 15.0 cm x 8.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

Managing low-level millivolt signals from field-mounted temperature sensors, the Honeywell MC-TAMT04 provides direct interface terminations for thermocouple input modules. Built to operate seamlessly within Honeywell distributed control architectures, this terminal board serves as a highly stable interface layer between field process environments and digital processing units. By handling raw sensor inputs with minimal signal attenuation, it ensures highly reliable process temperature data transmission.

Features

  • Onboard Cold Junction Compensation: Integrated reference sensors continuously monitor terminal temperatures to eliminate measurement offset errors.
  • Robust Industrial Terminations: Heavy-duty screw clamp terminals facilitate secure point-to-point field wiring connections.
  • Environmental Resilience: Conformance-coated circuitry provides reliable protection against dust, humidity, and atmospheric pollutants.
  • Simplified Mounting: Standard Field Termination Assembly (FTA) footprint mounts directly to DIN rail channels.
  • Low Noise Susceptibility: Optimized trace layouts minimize electromagnetic and radio frequency interference on sensitive millivolt circuits.

Applications

  • Honeywell Experion PKS and TDC 3000 Distributed Control Systems (DCS).
  • High-temperature kiln and industrial furnace monitoring.
  • Petrochemical and refining distillation column temperature control.
  • Power generation steam turbine and boiler exhaust gas monitoring.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model Number MC-TAMT04
Device Type Thermocouple Input Terminal Board
Cold Junction Compensation (CJC) Integrated onboard sensors
Termination Style Compression screw clamp terminals
Conformal Coating Yes
Mounting Configuration Standard FTA mounting channel
Country of Origin United States / Global OEM facilities
Shipping Weight (Calculated) 2.0 kg (4.4 lbs)
Package Dimensions (Calculated) 31.0 cm x 15.0 cm x 8.0 cm

Empirical Engineering Insights

Alternative Models & Compatibility

The MC-TAMT04 acts as a functional direct replacement for legacy non-coated terminal boards in standard TDC 3000 and PMIO chassis setups. When swapping older versions for the conformal coated MC-TAMT04, ensure the mating multi-pin connector alignment keys are uncompromised and the CJC parameters are correctly reconfigured in the controller database.

Application Pitfalls & Engineering Notes

Avoid installing this assembly directly in the path of cabinet cooling fan discharge. Rapid thermal gradients across the board's surface can outpace the response of the onboard CJC sensors, leading to localized temperature measurement drift and control system inaccuracy.

Commissioning & Wiring Tips

Always run matched thermocouple extension wire directly to the screw terminals without intermediate terminal blocks. Verify that shield drain wires are terminated strictly on the board's designated shield bar and grounded at a single, centralized system earth point to minimize electrical noise pickup.

Installation Guidelines

CRITICAL WARNING

Isolate all high-voltage sources and de-energize the cabinet before mounting or wiring the terminal assembly. Use a calibrated ESD wrist strap during handling to prevent electrostatic discharge from damaging the high-impedance input channels.

1

Securely snap the terminal board assembly onto the standard FTA mounting channel within your system cabinet.

2

Connect the system ribbon cable from the I/O processor module to the board's primary interface header.

3

Terminate the field thermocouple extension wires to their respective channels, observing strict polarity and shield grounding rules.

Does the MC-TAMT04 support integrated cold junction compensation?

Yes, this terminal board includes onboard CJC sensors to dynamically measure and compensate for terminal temperature fluctuations.

What is the recommended wiring practice for shields on the MC-TAMT04?

Shield drain wires should be terminated to the designated shield contacts on the board and grounded at a single, isolated ground point.

Is this terminal board compatible with older TDC 3000 systems?

Yes, the board features backward compatibility for classic TDC 3000 environments, as well as integrations inside modern Experion PKS PMIO cabinets.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Stany Zjednoczone

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...