1 z 1

Mitsubishi Electric Q13UDHCPU MELSEC Q Series CPU Module

Mitsubishi Electric Q13UDHCPU MELSEC Q Series CPU Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: Q13UDHCPU

  • Country of origin:Stany Zjednoczone

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 1200g

  • Dimensions: 27.4 mm x 98 mm x 89.3 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

Engineered to handle high-demand industrial processing, the Mitsubishi Electric Q13UDHCPU is a high-performance Universal Q-Series PLC processor designed for complex automation architectures. Integrating state-of-the-art sequencing and structured programming execution, this module provides the computation speed and memory bandwidth required for high-speed synchronization in discrete manufacturing, packaging, and heavy process control. It integrates natively with the MELSEC Q Series backplane system, facilitating low-latency communication with digital, analog, and intelligent function modules.

Key Features

  • Rapid Instruction Execution: Achieves a processing speed of 9.5 ns for basic LD sequence instructions and 19 ns for MOV data transfer instructions.
  • Substantial Memory Allocations: Features a 130K steps program capacity paired with 520 KB of built-in program memory and 1024 KB of standard RAM.
  • Extensive Physical and Logical I/O: Controls up to 4096 physical I/O points directly, with access to 8192 device points via direct memory mapping.
  • Multi-CPU System Support: Features a high-speed multi-CPU shared memory area of 32 KB for coordinate-control architectures.
  • Flexible Programming Environments: Fully compatible with Relay Symbol, MELSAP 3 (SFC), MELSAP-L, Function Blocks (FB), and Structured Text (ST) languages.

Applications

  • High-speed multi-axis assembly and automotive production lines.
  • Precision electronic and semiconductor manufacturing machinery.
  • Multi-tiered material handling, sorting, and warehouse logistics networks.
  • Comprehensive process instrumentation systems requiring distributed I/O execution.

Technical Specifications

Parameter Specification Values
Manufacturer Mitsubishi Electric
Model Code Q13UDHCPU
Series Type MELSEC Q Series (Universal QCPU)
Control Execution Method Stored program cyclic/iteration operation
Program Capacity 130K steps (520 KB)
Standard RAM (Drive 3) 1024 KB
Standard ROM (Drive 4) 2048 KB
Physical I/O Points 4096 Points (X/Y 0 to FFF)
Internal Current Consumption (5V DC) 0.39 A
Operating Temperature Range 0 to 55 degC (ambient)
Storage Temperature Range -25 to 75 degC
Module Dimensions (W x H x D) 27.4 mm x 98 mm x 89.3 mm
Unit Mass 0.20 kg
Shipping Weight (Calculated) 1.2 kg

Connections and Interfaces

Interface Type Functional Assignment & Description
USB Port Mini-B physical interface; supports high-speed program upload/download and online diagnostics via GX Works2.
RS-232 Port D-Sub 9-pin interface for legacy serial communication, direct HMIs, and peripheral telemetry.
Memory Card Interface Dedicated slot accepting SRAM (up to 8 MB), Flash (up to 4 MB), or ATA cards (up to 32 MB) for database storage and firmware storage.

Empirical Engineering Insights

Alternative Models & Compatibility

The Q13UDHCPU serves as a direct upgrade path for older Q02HCPU and Q06HCPU processors. However, note that while the form factor and backplane installation remain identical, transition from older High-Performance models to Universal models requires compiling the project configuration database inside GX Works2 and adjusting task schedules to prevent cycle timing variations due to the faster internal execution times.

Application Pitfalls & Engineering Notes

When operating multiple CPUs on a shared backplane, the high-speed CPU bus interface consumes shared memory bandwidth. Developers must configure proper interlocking structures within the 32 KB shared memory region to prevent write access overlap, which can trigger system watchdog errors (WDT) and halt process control loops.

Commissioning & Backup Strategies

To safeguard against battery decay and sudden shutdown logic corruption, commission standard ROM backups. We recommend structuring automatic firmware boot programs to load directly from Drive 4 (Standard ROM) at startup. Additionally, configure memory card partitions during initial setup using the diagnostic memory allocation utility inside the IDE.

Installation Guidelines

CRITICAL WARNING: Ensure all power to the main base unit (backplane) and external I/O terminals is completely disconnected before inserting or removing the CPU module. Failing to isolate external control voltages can result in backplane data bus corruption, permanent hardware damage, or system fault shutdowns.
1 Align the bottom guide lug of the CPU module with the base unit slot interface.
2 Gently push the top of the module forward until the secure latch locks into place on the backplane support framework.
3 Tighten the integrated security screw (where applicable) to prevent vibration-induced disconnections.
4 Connect the lithium backup battery to the designated battery terminal socket prior to running system configuration diagnostics.

What is the physical program capacity of the Q13UDHCPU module?

The module features a programming storage capacity of 130K steps, which translates directly to 520 KB of internal program memory.

Which programming languages does this Universal Q Series CPU support?

It supports standard industrial formats including Relay Symbol Word, Logic Symbolic Word, MELSAP 3 (SFC), MELSAP-L, Function Blocks (FB), and Structured Text (ST).

What is the processing speed for basic boolean instructions on this module?

It provides extreme high-speed execution, processing basic sequence instructions like LD X0 in 9.5 nanoseconds.

How do you backup the runtime program memory to prevent volatile loss?

The CPU includes standard ROM (Drive 4) memory of 2048 KB where the compiled system parameters and sequences should be written to prevent data loss when the system backup battery dies.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Stany Zjednoczone

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...