Siemens 6AV7613-0AE32-0BH0 SIMATIC Panel PC 670

Siemens 6AV7613-0AE32-0BH0 SIMATIC Panel PC 670

Only 5 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6AV7613-0AE32-0BH0

  • Country of origin:Niemcy

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: Not Provided

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

The Siemens 6AV7613-0AE32-0BH0 is a SIMATIC Panel PC 670, designed for industrial applications requiring a robust human-machine interface and computing platform. This unit features a 12-inch TFT display and comes in a standard configuration. It is equipped with a 40 GB hard drive, 256 MBYTE RAM, and a Pentium III 500 MHz CPU, providing a reliable foundation for control and visualization tasks. The Panel PC operates on a 115-230 V U.S. mains cable and runs on Windows NT 4.0 German, making it suitable for integration into existing automation environments.

Features

  • 12-inch TFT Display for clear visualization
  • Standard configuration for broad compatibility
  • Integrated 40 GB Hard Drive
  • 256 MBYTE RAM for system operations
  • Pentium III 500 MHz CPU for processing power
  • Supports 115-230 V U.S. mains power
  • Pre-installed Windows NT 4.0 German operating system
  • Robust design for industrial environments

Applications

The SIMATIC Panel PC 670 is suitable for a range of industrial automation applications, including:

  • Machine operation and control
  • Process visualization and monitoring
  • Data acquisition and logging
  • SCADA system integration
  • Factory automation and manufacturing execution systems (MES)
  • Building automation and infrastructure control

Technical Specifications

Parameter Value
Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC panels
Display Type 12" TFT Display
Configuration Standard
Hard Drive 40 GB HD
RAM 256 MBYTE RAM
CPU Pentium III 500 MHz
Power Supply 115-230 V U.S. Mains Cable
Operating System Windows NT 4.0 German
Product Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Safety First: Ensure all power to the installation area is de-energized and locked out before beginning any work.
  2. Mounting: Mount the Panel PC securely into a prepared panel cutout, ensuring adequate clearance for ventilation and cable routing. Use appropriate fasteners to prevent vibration.
  3. Power Connection: Connect the 115-230 V U.S. mains cable to a stable and protected power source. Verify correct voltage and grounding.
  4. Grounding: Establish a proper protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any necessary peripherals such as keyboards, mice, or external storage devices to the available ports.
  6. Network/Communication: If applicable, connect network cables or communication lines, ensuring proper shielding and routing away from power cables to prevent interference.
  7. Initial Power-Up: After all connections are secure, re-energize the power supply. Observe the Panel PC for proper boot-up and display functionality.
  8. Software Configuration: Configure the Windows NT 4.0 operating system and any application software as required for the specific industrial process.

What operating system is pre-installed on the 6AV7613-0AE32-0BH0?

The Siemens 6AV7613-0AE32-0BH0 comes with Windows NT 4.0 German pre-installed.

What are the display specifications of this Panel PC?

This Panel PC features a 12-inch TFT display.

What is the CPU and RAM configuration?

It is equipped with a Pentium III 500 MHz CPU and 256 MBYTE of RAM.

What power supply is required for the 6AV7613-0AE32-0BH0?

The unit requires a 115-230 V U.S. mains power supply.

Is this product still actively manufactured?

According to the product phase information, the 6AV7613-0AE32-0BH0 is an obsolete product.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Niemcy

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...