1 z 1

Siemens 6ES7710-3DA53-4FB2 SIMATIC Field PG Pentium III

Siemens 6ES7710-3DA53-4FB2 SIMATIC Field PG Pentium III

Only 2 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6ES7710-3DA53-4FB2

  • Country of origin:Niemcy

  • Product Type: Industrial Programming Device

  • Barcode: 85371099

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: Not specified

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

The Siemens 6ES7710-3DA53-4FB2 is a SIMATIC Field PG, a robust industrial programming device designed for the configuration, programming, and diagnostics of SIMATIC PLCs. This model features a Pentium III 850 MHz processor with a 256 KB 2nd Level Cache, complemented by 512 MByte RAM (configured as 2x256 MB SDRAM). It includes a 30 GByte EIDE Hard Disk Drive, a DVD-ROM / CD-RW drive, and a 1.44 MB Floppy Disk Drive for versatile data handling. The device operates on Windows 2000 MUI GEFSI and comes with essential SIMATIC programming software pre-installed, including STEP 7 Professional, STEP 5, and STEP 7 MicroWIN. It is supplied with a power cable suitable for various European regions, making it ready for immediate deployment in industrial environments.

Features

  • Pentium III 850 MHz Processor
  • 256 KB 2nd Level Cache
  • 512 MByte RAM (2x256 MB SDRAM)
  • 30 GByte EIDE Hard Disk Drive
  • Integrated DVD-ROM / CD-RW Drive
  • Integrated 1.44 MB Floppy Disk Drive
  • Pre-installed Windows 2000 MUI GEFSI Operating System
  • Includes pre-installed SIMATIC STEP 7 Professional, STEP 5, and STEP 7 MicroWIN software
  • Supplied with power cable for Germany, France, Netherlands, Spain, Belgium, Austria, Sweden, Finland

Applications

  • Programming and configuration of Siemens SIMATIC S7, S5, and MicroWIN series PLCs.
  • On-site diagnostics, troubleshooting, and maintenance for industrial automation systems.
  • Development and testing of control programs in industrial environments.
  • Data backup and restoration for automation projects.

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range SIMATIC Field PG
Subrange Field PG
Product Type Pentium 3 Programming Device
Processor Pentium III 850 MHz
Cache 256 KB 2nd Level Cache
RAM 512 MByte (2x256 MB SDRAM)
Hard Disk Drive 30 GByte EIDE
Optical Drive DVD-ROM / CD-RW
Floppy Disk Drive 1.44 MB
Operating System Windows 2000 MUI GEFSI
Pre-installed Software STEP 7 Professional, STEP 5, STEP 7 MicroWIN
Software Installation Date December 2001
Included Power Cable Regions Germany, France, Netherlands, Spain, Belgium, Austria, Sweden, Finland
PLM Product Phase Phase-Out
Logistics Weight 4.00 kg
Commodity Code 85371099
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Power Connection: Connect the provided power cable to the device's power input and a compatible mains outlet in the specified regions (Germany, France, Netherlands, Spain, Belgium, Austria, Sweden, Finland).
  2. Initial Setup: The device comes with Windows 2000 and SIMATIC programming software pre-installed. Ensure the operating system boots correctly and the software environment is accessible.
  3. Peripheral Connections: Connect necessary peripherals such as external monitors, keyboards, or mice via available ports if required for extended use.
  4. PLC Communication: Utilize the appropriate communication interfaces (e.g., serial, Ethernet, MPI/PROFIBUS if available) to connect the Field PG to the target SIMATIC PLC for programming, diagnostics, and data transfer.
  5. Data Management: Regularly back up critical project data from the internal hard disk drive to external media (e.g., CD-RW, USB drive if supported, or network storage) to prevent data loss.
  6. Environmental Considerations: Operate the Field PG within typical industrial office environments, ensuring adequate ventilation and protection from excessive dust, moisture, and extreme temperatures.

What is the primary function of the Siemens 6ES7710-3DA53-4FB2?

It is an industrial programming device designed for the configuration, programming, and diagnostics of Siemens SIMATIC PLCs.

What operating system is pre-installed on this Field PG?

The device comes with Windows 2000 MUI GEFSI pre-installed.

Which SIMATIC programming software is included?

It includes pre-installed STEP 7 Professional, STEP 5, and STEP 7 MicroWIN software.

What is the RAM capacity of this device?

The Field PG is equipped with 512 MByte RAM, configured as 2x256 MB SDRAM.

Is this device still actively manufactured by Siemens?

According to the PLM Product Phase, this model is in the Phase-Out stage.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Niemcy

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...