1 z 3

Yokogawa SNT501-13 ProSafe-RS Optical ESB Bus Repeater Module

Yokogawa SNT501-13 ProSafe-RS Optical ESB Bus Repeater Module

Only 10 item(s) left in stock
  • Manufacturer: Yokogawa

  • Product No.: SNT501-13

  • Country of origin:Japonia

  • Product Type: Optical ESB Bus Repeater Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 300g

  • Dimensions: 3.3cm x 10.7cm x 13cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Product Overview

The Yokogawa SNT501-13 (SNT501-13) is an Optical ESB Bus Repeater Slave Module engineered for the ProSafe-RS safety instrumented system (SIS). Widely deployed in high-consequence process industries such as oil refining, petrochemical processing, and power generation, this module extends critical safety communication networks over long physical distances. It receives optical signals transmitted from an SNT401 master module or N-ESB bus module via fiber-optic cabling and converts them back to electrical signals. These signals are then routed via an ESB bus cable to the SSB401 ESB Bus Interface Module residing on the SNB10D safety node unit. By isolating the communication path through fiber optics, this module prevents electromagnetic interference (EMI) and ground-loop propagation across remote processing areas, ensuring continuous system uptime and robust machinery protection.

Suffix Breakdown

The model and suffix code structure of the SNT501-13 dictates its environmental protection rating, explosive atmosphere certification, and maintenance designation:

  • SNT501: Base designator for the Optical ESB Bus Repeater Slave Module.

  • -1: Denotes a hardware build with no explosion protection, suitable for non-hazardous control room environments or installations utilizing external containment.

  • 3: Designates compliance with the ISA Standard G3 conformal coating specification for highly corrosive environments. This option also expands the certified operating temperature window to a wider range of -20 to 70 deg C, classified strictly for system maintenance and legacy support purposes.

Technical Specifications

Parameter Metric Certified Specification Value
Model SNT501-13
Brand Yokogawa Electric Corporation
Origin Japan
Function ESB Bus optical transport function (Slave side)
Connection Topology Star type or Chain type network architectures
Cascading Capability Maximum of 2 connecting stages
Transmission Distance Max 5 km (total two stages); Max 10 km on Vnet/IP R1.03 or later
Current Consumption 0.5 A
Operating Temperature -20 to 70 deg C (-4 to 158 deg F)
Environmental Protection ISA Standard G3 chemical resistance coating
Weight Approx. 0.3 kg

Technical FAQs

  • Q: Why is it critical that the suffix codes of the bus 1 and bus 2 modules match exactly?

    A: For redundant safety configurations, both the primary (bus 1) and secondary (bus 2) repeater modules must share identical electrical, thermal, and signal-propagation characteristics. Mismatching suffix codes (such as pairing a standard module with a G3-coated, wide-temperature -13 module) can introduce minor timing offsets, compromising the synchronization of the ProSafe-RS safety bus.

  • Q: Can the SNT501-13 module be paired with any master-side optical repeater?

    A: No. To maintain proper optical link budgets and communication integrity, the master side and slave side must be paired systematically. The SNT501-13 (SNT501-dash-13) slave module must be paired specifically with the corresponding SNT401-13 master module.

  • Q: What is the benefit of the ISA Standard G3 coating on this specific module?

    A: The G3 rating indicates that the module's printed circuit board (PCB) has a specialized conformal coating. This provides robust protection against chemical attack from corrosive gases (such as hydrogen sulfide, sulfur dioxide, and chlorine) commonly present in oil refineries, wastewater facilities, and paper mills.


Engineering & Installation Guide

  • Ensuring Fiber Connection Cleanliness: Before inserting the fiber-optic connectors into the SNT501-13, clean the cable end-faces using a dedicated fiber-optic reel cleaner or lint-free wipes saturated with industrial-grade isopropyl alcohol. Microscopic dust particles trapped in the optical transceiver interface can cause severe signal attenuation, leading to high bit-error rates on the ESB bus or communication timeouts.

  • Observing Minimum Bend Radius: During cabinet routing, ensure the fiber-optic cables do not exceed their specified minimum bend radius (typically 30 mm for standard multi-mode fiber). Sharp bends can cause micro-bends in the glass core, resulting in permanent optical power loss that reduces the maximum transmission distance below the rated 5 km or 10 km limits.

  • Redundant Path Physical Isolation: When implementing a redundant star or chain topology, route the fiber-optic cables for Bus 1 and Bus 2 through completely separate physical conduits and cable trays. This prevents a single physical impact, fire, or localized cabinet accident from severing both communication lines simultaneously, preserving safety system operation.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Brązowy Pomarańczowy
Country of origin
Japonia
Power source
Zasilanie prądem stałym

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...