Product Overview

The 060G2050 (060G2050) is a high-performance pressure transmitter from the Danfoss AKS 33 series, specifically engineered for refrigeration and air conditioning applications. Optimized for precision and stability, this sensor converts pressure into a standardized 4-20 mA current signal, ensuring reliable long-distance data transmission even in environments with high electromagnetic interference. The 060G2050 features a sealed gauge pressure reference and a robust design capable of withstanding media temperatures from -40 to 85 Celsius. Whether integrated into commercial chillers or industrial cooling racks, this transmitter provides the critical feedback necessary for energy-efficient evaporator and condenser control, significantly reducing the risk of system failures and compressor stress.

Technical Configuration

The 060G2050 is designed for seamless integration into advanced HVAC and refrigeration control loops:

  • Sealed Gauge Reference: Provides a stable pressure reference that is isolated from atmospheric pressure fluctuations, ensuring consistent readings in all climate conditions.

  • Precision Current Output: The 4-20 mA output signal is highly resistant to voltage drops across long cable runs, making it the preferred choice for large-scale industrial installations.

  • Enhanced Thermal Stability: Features an electronically compensated temperature range from 0 to 80 Celsius, maintaining signal accuracy despite varying ambient conditions.

  • Standardized Electrical Interface: Equipped with an EN 175301-803-A angular connector (DIN plug), providing a secure, IP65-rated connection that simplifies field replacement and maintenance.

Technical Specifications

Feature Specification
Model 060G2050 (Type AKS 33)
Brand Danfoss
Output Signal 4 - 20 mA Current
Pressure Reference Sealed Gauge
Overload Pressure 40 bar (580 psi)
Electrical Connection EN 175301-803-A Angular Connector
Enclosure Rating IP65
Medium Temp. Range -40 to 85 deg C
Compensated Temp. 0 to 80 deg C
Net Weight 0.152 kg
Shipping Weight 1.0 kg

Technical FAQs

How does the current output benefit refrigeration control?

The 4-20 mA signal produced by the 084G2050 is inherently immune to electrical noise and line resistance. Unlike voltage-based sensors, the current signal remains constant regardless of the cable length, ensuring that the controller receives an exact pressure reading even if the sensor is located far from the electrical panel.

Is the AKS 33 compatible with ammonia (R717)?

Yes, the AKS 33 series is designed to be compatible with most common refrigerants, including ammonia and halogenated refrigerants. Its stainless steel construction ensures resistance to chemical corrosion common in industrial cooling systems.

What is the significance of the "Sealed Gauge" reference?

A sealed gauge reference uses an internal vacuum or set pressure as a baseline. This prevents the sensor from being affected by changes in barometric pressure due to altitude or weather, which is essential for maintaining accuracy in high-pressure refrigeration cycles.


Engineering & Installation Guide

  • Vibration and Pulse Protection: To ensure maximum sensor longevity, mount the 060G2050 on a vibration-damped bracket rather than directly on a reciprocating compressor. If the system is prone to liquid hammer or high-frequency pulses, install a capillary tube or a pressure snubber between the pipe and the transmitter.

  • Electrical Connection Security: When installing the angular connector (EN 175301-803-A), ensure the rubber gasket is correctly seated before tightening the central screw. This is critical to achieving the IP65 rating and preventing moisture from corroding the electrical pins in humid mechanical rooms.

  • Wiring for 4-20 mA Loops: Ensure the power supply is between 9 and 32 VDC. Always use shielded, twisted-pair cabling for signal lines and ground the shield at the controller end only to prevent ground loops that could distort the 0.5% typical accuracy.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...