Danfoss

060G2111 Danfoss AKS 33 High-Precision Pressure Transmitter

SKU 060G2111

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 060G2111

  • Country of origin:United States

  • Product Type: Pressure Transmitter | AKS 33

  • Payment: T/T, Western Union

  • Weight: 168g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 060G2111 (060G2111) is a specialized pressure transmitter from the Danfoss AKS 33 series, specifically engineered for high-performance monitoring within refrigeration and air conditioning systems. This sensor generates a 4 to 20 mA current output signal, ensuring high noise immunity and stable data transmission even across long distances. Designed with a sealed gauge pressure reference, the 060G2111 is inherently protected against atmospheric humidity and pressure fluctuations, making it an ideal choice for low-temperature environments where moisture ingress can compromise standard sensors. With a robust overload capacity of 33 bar (479 psi), it provides the durability required for reliable operation in demanding commercial and industrial cooling circuits.

Technical Configuration

The hardware of the AKS 33 series is built for precision under fluctuating thermal conditions. The 060G2111 maintains a wide ambient and medium temperature range from -40 to 85 deg C. For mission-critical accuracy, the transmitter features a compensated temperature range of -30 to 40 deg C, where thermal drift is electronically neutralized to ensure linear output. Electrical connection is facilitated via a standard EN 175301-803-A angular connector, which provides an IP65 enclosure rating to resist dust and water ingress. The compact, lightweight design (0.168 kg) allows for direct installation on manifolds or piping, facilitating fast response times for compressor control and system diagnostics.

Technical Specifications

Feature Specification
Model 060G2111
Brand Danfoss
Series AKS 33
Output Signal 4 to 20 mA
Pressure Reference Sealed Gauge
Overload Pressure 33 bar (479 psi)
Ambient Temp Range -40 to 85 deg C
Compensated Temp Range -30 to 40 deg C
Electrical Connection Angular connector (EN 175301-803-A)
Enclosure Rating IP65
Weight 0.168 kg
Shipping Weight 1.0 kg

Technical FAQs

How does the sealed gauge reference benefit refrigeration cycles?

Standard gauge sensors rely on atmospheric venting, which can allow humid air to enter the sensor body. In refrigeration, this often leads to internal condensation and frost. The sealed gauge reference of the 060G2111 uses a fixed 1 bar internal reference, completely isolating the sensing element from the external environment.

What is the significance of the 4-20 mA current signal for this sensor?

The 4-20 mA current loop is the industrial standard for reliability. Unlike voltage signals, it is not affected by voltage drops over long cables and is highly resistant to electromagnetic interference (EMI) from nearby motors or variable frequency drives.

What happens if the pressure exceeds the 33 bar overload limit?

The 33 bar limit is the maximum pressure the sensor can withstand without suffering mechanical damage. If this limit is exceeded, the internal diaphragm may undergo permanent deformation, resulting in a shifted zero point or total failure of the transmitter.


Engineering & Installation Guide

  • Pulsation Dampening: When installing the 060G2111 near a reciprocating compressor, use a capillary tube or a pressure snubber. Direct exposure to high-frequency pressure pulsations can cause mechanical fatigue in the sensing element over time.

  • Moisture Protection: To maintain the IP65 integrity, ensure the angular connector gasket is correctly seated and the central fastening screw is tightened. Always implement a "drip loop" in the wiring—directing the cable downward before it enters the connector—to prevent water from tracking along the cable and into the electronics.

  • Wiring Configuration: This is a 2-wire transmitter. Connect the positive supply to Pin 1 and the signal/return to Pin 2 of the EN 175301-803-A connector. Ensure the power supply is stable 24 VDC (typically 10 to 30 VDC) to maintain a linear 4-20 mA output across the full pressure range.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...