The Rosemount 1056-01-21-31-AN is a sophisticated dual-channel multi-parameter transmitter designed for demanding liquid analysis. This specific configuration is optimized for Dual Toroidal Conductivity measurements, allowing for simultaneous monitoring of two separate process lines or the calculation of differential conductivity in high-concentration chemical applications.

Technical Specifications

Category Specification
Manufacturer Rosemount (Emerson)
Model 1056
Power Supply 115/230 VAC, 50/60 Hz (No Relays)
Measurement 1 Toroidal Conductivity
Measurement 2 Toroidal Conductivity
Output / Communication Dual 4-20 mA Analog Outputs
Operating Temperature 0 to 55 °C (32 to 131 °F)
Enclosure Rating NEMA 4X / IP66
Shipping Weight 5.0 kg

Measurement Capability

  • Toroidal (Inductive) Method: Ideal for high-conductivity liquids, slurries, or corrosive chemicals that would foul or coat standard contact electrodes.

  • Dual Display: The large, high-contrast LCD displays both measurements simultaneously with user-defined units.

  • Auto-Configuration: The transmitter automatically recognizes the measurement boards upon power-up.


Installation & Wiring Guidelines

  • Mounting Options: The 1056 is versatile and can be mounted via panel-mount (1/2 DIN), pipe-mount, or surface-mount. Ensure the rear cable glands are tightened to maintain the NEMA 4X seal.

  • Power Connection: This unit is configured for 01 (AC Power). Internal jumpers or terminal selection must be checked to match your local supply of 115 VAC or 230 VAC.

  • Sensor Compatibility: This model requires Toroidal sensors (e.g., Rosemount 222, 225, or 228 series). Ensure the sensor cable is properly shielded and routed away from high-power VFD or motor cables.

  • Analog Outputs: The dual 4-20 mA outputs are isolated. They can be mapped to represent Conductivity 1, Conductivity 2, or the temperature of either process.


Frequently Asked Questions (FAQs)

Why choose Toroidal conductivity over Contacting conductivity?

Toroidal sensors are "non-contacting." They use induction to measure conductivity, making them nearly maintenance-free in applications that involve heavy oils, fibrous slurries, or high-acid/base concentrations that would corrode standard sensors.

Does this model include alarm relays?

No. The "01" power option in this specific product code indicates "no relays." If your application requires local high/low alarm triggers, you must utilize the 4-20 mA signals to an external PLC or DCS, or select a different hardware configuration.

How do I calibrate the dual channels?

Calibration is performed through the front-panel membrane keypad. You can perform a "Zero" calibration in air and a "Standard" calibration using a solution of known conductivity or by comparing it to a grab sample.

Is the display visible in direct sunlight?

Yes, the 1056 features a high-contrast, black-on-white LCD that is designed for high visibility in both indoor industrial lighting and outdoor daylight conditions.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...