Product Overview

The 134F2982 (134F2982) is a high-performance VLT AutomationDrive FC 360 frequency converter, specifically engineered for precision motor control in demanding industrial environments. With a power rating of 18.5 kW (25 HP) and a high overload (H) design, this drive is built to handle heavy-duty startup torques and fluctuating loads typical in manufacturing and process industries. The 134F2982 is an ideal solution for applications such as conveyor systems, mixers, and heavy-duty pumps, providing a balance of compact design and robust electrical performance. Featuring coated PCBs (Class 3C3) and a built-in brake chopper, it ensures high reliability and operational safety even in harsh conditions characterized by chemical moisture or rapid deceleration requirements.

Suffix Breakdown

The model code FC-360H18KT4E20H2BXCDXXSXXXXAXBX provides a detailed map of the drive’s internal hardware and software configuration:

  • FC-360: VLT AutomationDrive 360 Series.

  • H: High Overload rating for heavy-duty starting.

  • 18K: Power size of 18.5 kW / 25 HP.

  • T4: Three-phase input voltage range of 380 to 480 VAC.

  • E20: IP20 / Chassis enclosure rating for cabinet mounting.

  • H2: Integrated RFI Filter Class A2 (EN 55011).

  • B: Internal Brake Chopper included for regenerative energy management.

  • X: No Display unit (Blind cover configuration).

  • C: Coated PCB for enhanced protection against corrosive environments.

  • D: Loadsharing option included for DC bus synchronization.

  • AX: Standard Control Card configuration.

Technical Specifications

Feature Specification
Model 134F2982
Brand Danfoss
Series VLT AutomationDrive FC 360
Power Output 18.5 kW / 25 HP
Input Voltage 380 to 480 VAC (3-phase)
Overload Capacity High Overload (H)
Enclosure Rating IP20 / Chassis
RFI Filter Class A2
Brake Chopper Integrated
PCB Coating Coated (Class C)
Cooling Forced Air (Internal Fan)
Dimensions Standard FC 360 Frame Size
Weight 11.97 kg
Shipping Weight 14.0 kg

Technical FAQs

Can the 134F2982 be used in environments with high humidity or chemical exposure?

Yes. The "C" suffix in the configuration indicates that the PCBs are coated. This provides superior protection against dust, moisture, and corrosive chemical vapors, making it suitable for wastewater treatment or chemical processing plants.

Does this model include a local control panel (LCP)?

No. The "X" in the display position indicates this unit is shipped without a display. For commissioning or local monitoring, an external LCP must be connected, or the drive can be configured via a PC using the Danfoss VLT Motion Control Tool MCT 10.

What is the purpose of the integrated Brake Chopper?

The integrated brake chopper allows the drive to connect directly to an external braking resistor. This is essential for applications with high inertia that require rapid deceleration, as it allows the drive to dissipate regenerative energy safely without triggering a DC-link overvoltage trip.


Engineering & Installation Guide

  • Loadsharing Configuration: This unit (D option) supports loadsharing via the DC bus. When connecting multiple drives in a loadsharing setup, ensure that the DC-link fuses are sized correctly and that the voltage potential between the drives is synchronized to prevent circulating currents that could damage the capacitors.

  • Cabinet Thermal Management: Since this is an IP20/E20 chassis unit, it must be installed in a protected control cabinet. With an 18.5 kW power rating, the drive generates significant heat at full load. Ensure the cabinet has forced ventilation and maintain a minimum vertical clearance of 100 mm above and below the drive to facilitate proper airflow through the heat sink.

  • RFI/EMC Compliance: The integrated H2 RFI filter meets Class A2 standards. To maintain this compliance, motor cables must be shielded and the shield must have 360-degree contact with the ground plate. Ensure the motor cable length does not exceed the maximum specified for Class A2 to prevent electromagnetic interference with sensitive control electronics.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...